| 1 | Stripping off worn plaster and raking out joints of walls, ceiling etc………… within a lead of 75m asdirected.[ Page No-11 Item No-10] |
| 2 | Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemicalemulsion by admixing chloropyrofos emulsifiableconcentrates (1% concentration) with water by weight at the rate of 5 liters per sq.m of the surface……… as perspecification described in para 6.4 code IS-6313 (part-II)[ Page No-6 Item No-10 (c)] |
| 3 | Cleaning the exposed reinforcement preferably upto fulldiameter ………… as per manufacture specification.[Page No- 45 Item no-6 ] |
| 4 | Cleaning the concrete surface by removing dirt and debrismaking defective locations …………………… as per directions of the Engineer- in-Charge.[Page No- 45 Item no-5 ] |
| 5 | ReInforcement for reinforced concrete work in all sorts ofstructures including distribution bars, stirrups binders etc ……… as per drawing and direction.(a) For works in foundation, basement and upto roof of ground fioor /upto 4 m(i) Tor steel / Mild steel[ Page No-43 to 44 Item No-40 (a) (i)] |
| 6 | Weiding in M.S structural work with gas or electric.(a) Tack weld [ Page No-81 Item No-31 (a) (b)] |
| 7 | (b) Continuous weld[ Page No-81 Item No-31 (a) (b)] |
| 8 | Applying two coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion.[ Page No-45 Item No-8 ] |
| 9 | Applying epoxy based reactive joining agentfor joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).[ Page No-45 Item No-7 ] |
| 10 | Cement concrete ( 1:1.5:3 ) with graded stone chips 6 mm… the Engineer -in -Charge.(b) 25 mm thick[Page No-40 Item No-27 (b) ] |
| 11 | (c) 37.5 mm thick[Page No-40 Item No-27 (b) ] |
| 12 | Earth work in excavation of foundation trenches or drains, in all sorts of soil …………………… as requiredcomplete.(a) Depth of excavation not exceeding 1500 mm[ Page No-1 Item No-2 (a) ] |
| 13 | (A) Filling in foundation or plinth by silver sand in layersnot exceeding 150 mm as directed …………… including the cost of supply of sand.[ Page No-2 Item No-4 (A) ] |
| 14 | Single Brick Flat Soling inclunding ramming and dressingdressing bed to proper level and filling joints with localsand.[ Page No-5 Item No-10 (a) ] |
| 15 | Ordinary Cement concrete (mix 1:2:4) with graded stonechips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.(a) Pakur Variety[ Page No-24 Item No-4 ] |
| 16 | Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor[ Page No-15 Item No-8 (a) (b) ] |
| 17 | 125 mm thick brick works in cement mortar (1:4) in ground floor.[ Page No-16 Item No-16 ] |
| 18 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shutteringand reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety[ Page No-26 Item No-10 (i) ] |
| 19 | Hire and labour charges for shuttering with centering andnecessary staging ………… completion ofworks.(a) 25 mm to 30 mm thick wooden shuttering as perdecision & direction of Enginneer-in-Charge.[ Page No-42 Item No-36 (a) ] |
| 20 | Plaster (to wall ,floor, ceiling etc.) with sand cement …. where necessary (ground floor)(i) with 1:4 cement mortar(a) 20 mm thick plaster [Page No-189 Item No-1 (i) (b) ] |
| 21 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5 mm thick)[ Page No-204 Item No-5 (b) ] |
| 22 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc .……… smoothening surfaces by sand papering etc.[Page No. 200 Item No. 1 (b)(a)] |
| 23 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc .……… smoothening surfaces by sand papering etc.[Page No. 200 Item No. 1 (b)(a)] |
| 24 | Painting Best Qlty. syanthetic enamel paint of approved Qlty …… if necessary.(a) On timber or Plaster Surface. Two Coats.[Page No. 200 Item No. 2(a) (b)] |
| 25 | (b) On steel or other metal Surface.Two Coats[Page No. 200 Item No. 2(a) (b)] |
| 26 | Supply of Mazdoor (Male).[Page No-303 Item No-3 ] |
| 27 | M.S works in brackets made from flats, angles , tee etc. to sizes …………… with necessary bolts, nuts, washer or screws etc.[ Page No-103 Item No-8 ] |
| 28 | Weiding in M.S structural work with gas or electric.(a) Tack weld [ Page No-81 Item No-31 (a) (b)] |
| 29 | (b) Continuous weld[ Page No-81 Item No-31 (a) (b)] |
| 30 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre ……… corrugation minimum side lap.(i) In Roof:- (a) With 0.5 mm thick sheet[ Page No-82 to 83 Item No-14 (i) (a) ][ Page No-77 Item No-7 ] |
| 31 | Supplying 1.50 mm thick M.S sheet fitted and fixed on one or both faces ……… including cost of alllabour and materials.[Page No- 105 Item No-15 ] |
| 32 | 50 mm thick interlocking designer concrete paver blockM-30 grade for non-traffic zone, building premises,garden,parks,domestic drive as per IS: 15658-2006 ……… but excluding cost of base course & subgradeparks,domestic drive as per IS: 15658-2006 ……… but excluding cost of base course & subgradepreparation.(ii) Coloured Decorative[ Page No-75 Item No-48 (b) ] |
| 33 | Supply of UPVC pipes (B Type) & fittings conformingto IS-13592-1992.(A) (i) Single Socketed 3 Meter Length(c) 160 mm(B) Fittings(xi) Door Bend (T.S.)[ Page No-68 to 71 Item No-23 (A) (i) (c) , (xi)(b) (c)(xvi) (b) (c)] |
| 34 | (c) 160 mm[ Page No-68 to 71 Item No-23 (A) (i) (c) , (xi)(b) (c)(xvi) (b) (c)] |
| 35 | Labour for fitting and fixing U.P.V.C pipes for above groundwork including cost of jointing materials ……… Of the Engineer-in- charge.(A) Under ground(ii) 160 mm dia[ Page No-74 Item No-24 (B) (iii) ] |
| 36 | Constructing Inspection pit of inside measurement 600mm x 600mm x upto 600mm (depth) with 250mmthick 1st class brick work in cement mortar (1:4) on allsides, ……… with all cost of labour and materials.(i) with Pakur variety (SAIL/TATA/RINL)[ Page No-S & P-87 Item No-1 (i) ][ Page No-77 Item No-7 ] |
| 37 | Wood work in door and window frame fitted and fixed inposition complete ……………… and M.S clamps.(c) Sal : Siliguri [ Page No-114 Item No-1 (c) ] |
| 38 | Supplying solid flush type doors of commercial qualitythe timber frame ……… Excluding the cost of hinges and other fitting in ground floor.(b) 32 mm thick shutters (single leaf)[ Page No-124 Item No-11 (b) ] |
| 39 | Supplying, fitting and fixing M.S.clamps for door and window frame …… as per direction.(a) 40 mm x 6 mm. 250 mm Leanth [ Page No-140 Item No-4 (a) ] |
| 40 | Iron butt hinges of approved quality fitted and fixed withsteel screws, with ISI mark.(vi) 100 mm x 50 mm x 1.25 mm[ Page No-144 Item No-26 (v) ] |
| 41 | Anodised aluminium barrel / tower / socket bolt ………… with cadmium plated screws.(v) 150 mm long x 12 mm dia. bolt.[ Page No-140 Item No-5 (vi) ] |
| 42 | Anodised aluminium Aldrop / Sliding bolt …… fitted and fixed complete.(i) 250 mm x 16 mm dia bolt[ Page No-145 Item No-28(vi) ] |
| 43 | Hydraulic door closer of approved quality as per I.S.I standard fiied and fixed complete.(a)Heavy type (I.S.I size 3)[ Page No-143 Item No-23(i) ] |
| 44 | Door stopper (Brass)[ Page No-143 Item No-19(i) ] |
| 45 | Supply of santras[ Page No-303 Item No- 13 ] |
| 46 | Supply of Carpenter[ Page No-303 Item No-5 ] |
| 47 | Supply of Carpenter (Helper)[ Page No-303 Item No-7 ] |
| 48 | (a) M.S or W.I Ornamental grill of approved design jointscontinuously welded with M.S, W.I Flats …………… In ground floor.(a) Grill weighing above 10 Kg./sq.m and up to 16 Kg/sqm[ Page No-104 Item No-13 (i) ] |
| 49 | Making one set of scaffolding only for replacing glasspanels, painting, uprooting plant …………… of the Engineer-in-charge.(a) 3.90 metre hight[ Page No-23 to 24 Item No-3(a)] |
| 50 | (b)Extra for additional 3.6 height or part thereof.[ Page No-23 to 24 Item No-3(a)] |
| 51 | Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm x600 mm x10 mm thick) ………… direction of Engineerin-charge.(II) With polymerised Adhesive [6 mm thick ] & epoxygrouting materials for filling joints including spacer-2 mm(A) Deep colour & White[ Page No-66 Item No-36 (II) (B) ] |
| 52 | Supplying, fitting, fixing marble slab / tiles, 15 mm. to 18 mm. thick in dado / wall in 15 mm thick [avg] cementmortar (1:2 ) ………… curing complete.(a) With Chawk Doongri.(iv) Area of each slab/tile exceeding 1.00 sqm.[ Page No-56 Item No-25 (b) (iv) ] |
| 53 | Supplying, fitting, fixing granite slabs 15 mm. to 18 mmthick with uniform texture & without decorative veins in coiumns, wall, facia,rise etc. with 15 mm thick [avg] ………… of concrete surface complete.(b) Area of each Granite slab above1.00 Sqm.[ Page No-63 Item No-33 (b) ] |
| 54 | Supplying,fitting and fixing boiling water resistant plyconforming to IS:303-1989 bonded with …………… direction of Engineer-in-Charge.(ii) 6mm[Page No- 173 Item No-3 (ii) ] |
| 55 | Supplying, fitting and fixing boiling water proof blockboard conforming to IS: 1659-1990 conforming to ……… as per direction of Engineer-in-charge.In Ground Floor(i) 16mm[Page No- 173 Item No-4 (i) ] |
| 56 | Supplying fitting,fixing decorative lamination conformingto IS: 2046 : 1995 as per approved make, brand …… as per direction of Engineer-in-Charge.(i) Thickness of laminate 1.5 mm[Page No- 179 Item No-14 (i) ] |
| 57 | S.F.& F in position 10-15 micron anodised (mat finishIS -1855-199) heavy duty aluminium door & window for any floor.(a) Openable PortionAnalysis Rate. Ref Tender No. C-61 /11-12 |
| 58 | (b) Fixed PortionAnalysis Rate. Ref Tender No. C-61 /11-12 |
| 59 | Removal of rubbish,earth etc. from the working site…. & cleaning the site in all respect as per direction of EIC.[Page No-12 Item No-13] |
| 60 | Cutting chase upto 125 x 150 mm and subsequent mending of damages.(a) In brick wall.[ Page No-12 Item No-11 ] |
| 61 | Applying Exterior grade Acrylic primer of approved qualityand brand …………… as per direction of the EIC.(b) Two coats[ Page No-196 Item No-8 (b) ] |
| 62 | Protective and Decorative Acrylic exterior emulsion paintof approved quality as per manufacturer's specification…..……… the cost of primer.(b) premium 100% Acrylic Emulsion[ Page No-197 Item No-17 (b) ] |
| 63 | (A) Providing and fixing of false ceiling with powder coatedexposed G.I grid suspension system …………… direction of Engineer-in-charge.A) False Ceiling (with 6mm thick Fibre Cement DesignerBoard and E-Grid T-2430)[Page No- 158 Item No-3 ] |
| 64 | Collapssible gate wth 40 mm x40 mm x 6 mm Tee as top and bottom guide rail……………..good damagescomplete.[ Page No-106 Item No-18 ] Please Enable Macros to View BoQ information |