| 1 | Design, Manufacturing, Supply, installation, testing, commissioning and maintenance during w arranty period of Heavy Duty passenger escalator for vertical height of 6 meter at Railway stations over NR c onforming to RDSO specification no.-RDSO/PE/SPEC/TL/0095 (Rev-4)-2026 dated 16.01.2026, with warranty o f 2 years and Comprehensive Annual Maintenance Contract (CAMC) for 05 years after expiry of warranty peri od. Note:- The standard vertical height of escalator is 6 meters. The supplier shall be given +0.6% of quoted rate with variation of vertical heights +0.15 meters i.e. if the height become 6.15 meter then the amount pai d to bidder will be 1.006 times quoted rate and if height becomes 5.85 meter than amount paid will be 0.99 4 times of quoted rate. For a height variation on higher side of standard height, example for 6.00-6.14 m, pa yment will be on the basis of escalator height of lower limit of slab i.e. 6.00 m while for a height variation on l ower side slab of standard height i.e. for 5.85-5.99 m, payment will be on the basis of next higher slab of esc alator height i.e. 6 m. The details required as per RDSO specification Annexure-1 MB Div. [ Warranty Perio d: 24 Months after the date of delivery ] ] |
| 2 | Comprehensive Annual maintenance contract (CAMC) of installed Escalators for 5 years after t he expiry of warranty period of 2 years. [ Warranty Period: 2 years, AMC Period: 5 years, Rate of Disco unting: 8 % ] ] |
| 3 | Design, Manufacturing, Supply, installation, testing, commissioning and maintenance during w arranty period of Heavy Duty passenger escalator for vertical height of 6 meter at Railway stations over NR c onforming to RDSO specification no.-RDSO/PE/SPEC/TL/0095 (Rev-4)-2026 dated 16.01.2026, with warranty o f 2 years and Comprehensive Annual Maintenance Contract (CAMC) for 05 years after expiry of warranty peri od. Note:- The standard vertical height of escalator is 6 meters. The supplier shall be given +0.6% of quoted rate with variation of vertical heights +0.15 meters i.e. if the height become 6.15 meter then the amount pai d to bidder will be 1.006 times quoted rate and if height becomes 5.85 meter than amount paid will be 0.99 4 times of quoted rate. For a height variation on higher side of standard height, example for 6.00-6.14 m, pa yment will be on the basis of escalator height of lower limit of slab i.e. 6.00 m while for a height variation on l ower side slab of standard height i.e. for 5.85-5.99 m, payment will be on the basis of next higher slab of esc alator height i.e. 6 m. The details required as per RDSO specification Annexure-1 LKO Div. [ Warranty Perio d: 24 Months after the date of delivery ] ] |
| 4 | Comprehensive Annual maintenance contract (CAMC) of installed Escalators for 5 years after t he expiry of warranty period of 2 years. [ Warranty Period: 2 years, AMC Period: 5 years, Rate of Disco unting: 8 % ] ] |
| 5 | Design, Manufacturing, Supply, installation, testing, commissioning and maintenance during w arranty period of Heavy Duty passenger escalator for vertical height of 7 meter at Railway stations over NR c onforming to RDSO specification no.-RDSO/PE/SPEC/TL/0095 (Rev-4)-2026 dated 16.01.2026, with warranty o f 2 years and Comprehensive Annual Maintenance Contract (CAMC) for 05 years after expiry of warranty peri od. Note:- The standard vertical height of escalator is 7 meters. The supplier shall be given +0.6% of quoted rate with variation of vertical heights +0.15 meters i.e. if the height become 7.15 meter then the amount pai d to bidder will be 1.006 times quoted rate and if height becomes 6.85 meter than amount paid will be 0.99 4 times of quoted rate. For a height variation on higher side of standard height, example for 7.00-7.14 m, pa yment will be on the basis of escalator height of lower limit of slab i.e. 7.00 m while for a height variation on l ower side slab of standard height i.e. for 6.85-6.99 m, payment will be on the basis of next higher slab of esc alator height i.e. 7 m. The details required as per RDSO specification Annexure-1 DLI Div. [ Warranty Perio d: 24 Months after the date of delivery ] ] |
| 6 | Design, Manufacturing, Supply, installation, testing, commissioning and maintenance during w arranty period of Heavy Duty passenger escalator for vertical height of 9 meter at Railway stations over NR ( GSU/DLI) conforming to RDSO specification no.-RDSO/PE/SPEC/TL/0095 (Rev-4)-2026 dated 16.01.2026, with warranty of 2 years and Comprehensive Annual Maintenance Contract (CAMC) for 05 years after expiry of wa rranty period. Note:- The standard vertical height of escalator is 9 meters. The supplier shall be given +0.6% of quoted rate with variation of vertical heights +0.15 meters i.e. if the height become 9.15 meter then the a mount paid to bidder will be 1.006 times quoted rate and if height becomes 8.85 meter than amount paid wi ll be 0.994 times of quoted rate. For a height variation on higher side of standard height, example for 9.00-9. 14 m, payment will be on the basis of escalator height of lower limit of slab i.e. 9.00 m while for a height vari ation on lower side slab of standard height i.e. for 8.85-8.99 m, payment will be on the basis of next higher sl ab of escalator height i.e. 9 m. The details required as per RDSO specification Annexure-1 DLI Div. [ Warran ty Period: 24 Months after the date of delivery ] ] |
| 7 | Comprehensive Annual maintenance contract (CAMC) of installed Escalators for 5 years after t he expiry of warranty period of 2 years. [ Warranty Period: 2 years, AMC Period: 5 years, Rate of Disco unting: 8 % ] ] |
| 8 | Comprehensive Annual maintenance contract (CAMC) of installed Escalators for 5 years after t he expiry of warranty period of 2 years. [ Warranty Period: 2 years, AMC Period: 5 years, Rate of Disco unting: 8 % ] ] |