| 1 | Excavating over areas, exc 1.5m but n. exc 3.0m deep and getting out in hard/dense soil including demolition of floor marble at site complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate, as in foundation filling, sub base of floor, etc complete all as specified and directed. |
| 3 | M&L high strength steel deformed TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9.mm dia, etc complete all as specified and directed. |
| 4 | M&L for Mild steel bars (TMT bars) 5mm dia and over upto and including 10mm dia in stirrups, spaces, nibs and binders complete all as specified and directed. |
| 5 | M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter finised fair complete all as specified and directed. |
| 6 | M&L RCC M-25 (Design Mix) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | Returning filling in trenches, incl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified anf directed. |
| 8 | Removing excavated material (soil) to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick cement plaster in CM 1:6 on other than fair faces of brick work or concrete surfaces and surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for applying two coats of 1st Quality oil emulsion distemper over new prepared surface of wall with 2 mm thick wall care putty complete all as specified and directed. |
| 11 | S&F 12mm thick Frosted Toughned Glass panels including necessary bracket/bolts/Spider fitting and all other fixing arrangement for lift chamber/well complete all as specified and directed. |
| 12 | S&F SS Frame work for Toughned Glass Lift Chamber including all fixing arrangement complete all as specified and directed. |
| 13 | Design, supply, installing, testing & commissioning electrically operated 08 passenger (544Kgs) lift along with MS Shaft & loading frame at Infantry Museum & Research building, speed 1.0 m/s,lift with single speed motor 415 V , 3 Phase, AC 50 Hz supply confirming to IS 14665, suitable to serve G+02 upper floors i.e with 03 stops and 03 landings with or without attendant with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive(electric motor driven mechanism), sliding stainless steel doors, automatic rescue device(ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (02 Nos one each in car & near ground floor landing door) including complete Civil Works as shown on Sketch complete all as specified and directed. |
| 14 | The Lift & Shaft requirements are as under :-(i) Car travel:-G+02 travel approx 15 metre(ii) Landing entrance:- Auto door CO SS silver finish 1.5mm thick with 800 x 200 mm vision panel(iii) Car inner dimensions(WXD):- 1300x1100 mm (however dimensions may vary as per site).(iv) Clear Entrance(WXH):- 800x2000mm (v) Type Of Machine:-Gearless(vi) Signals:- Emergency alarm bell up/down,direction indicators,digital position indicator in car and landing ,audible floor hooter,emergency stops etc.(vii) Gearless machine unit -As per OEM.(viii) Ropes:- Usha Martin(ix) Controller:- Microprocessor/latest technology based- As per OEM(x) MS Shaft & enclosed with Toughned glass(XI) RCC PitNote :- Contractor shall submit Drg & Design of Shaft,Pit as per IS and vetted by Govt.Engineering collage before execution for approval of accepting officer this all includes in lum sum quoted by the contractor.(ii) Contractor shall submit the design, specifications, drawings of the lift for approval from Accepting Officer before placing order for procurement. |
| 15 | The technical specifications of lift, shaft are as under : (I) DETAILS OF LIFT : Lift Type - Passanger Lift Rated Capacity Persons / Kgs - 8 Person/544 Kgs Rated Speed m/s - 1.25 Number of stops / openings - 3/3 Floor Designation - G+2 Access sides Inline/Thru Type - One (front only) Floor Display Character (Entrance Position) - 0(F), 1(F), 2(F) Machine and Controller details Machine Location/Type - Machine Roomless- Gearless Drive System - Micro Processor Based VVVF Control System - Microprocessor Based Simplex Selective Collective Control With/Without Attendent Main Power Supply - AC 3 Phase, 50 Cycles, 415 Volts +(-)10% Light Power Supply - 220 Volts 50 Hz LNE (II) SHAFT DETAILS Shaft Type (to be constructed as Per IS - STEEL - Steel structure 800:2007, IS14665:2000 and relevant IS Shaft Width mm X Shaft Depth mm - 1900 X 1900 (as per IS :14665:2000 and relevant IS) Overhead mm - 4500 Pit Depth mm - 1600 Travel Height (in Meters) - 14 Enclosed With - 12 mm Toughned Glass with adequate packing & frame |
| 16 | (III) CAR CABIN DETAILS : Car size (width X depth mm) - 1300 X 1100 Car clear height mm - 2200 Car Door Type Center/Side - Power operated Centre opening sliding No of Door panels - 2 Panel Type of Door Drive - Linear door drive System Car Door (WX H) mm - 800 X 2000 mm Material of Car Cabin - Stainless Steel (1.5 mm) Lift Cabin Finish - Hairline Finish Ceiling Finish - SS Hairline Finish Fan - Cross Flow Fan Flooring Type - Granite Hand rail Type - stainless steel (round) Handrail (IV) LANDING DOORS DETAILS Door Type - Centre Opening sliding Door Door Size (WXH) mm - 800 X 2000 Door Sill - Aluminium - Landing Door Finish - 1-3 stainless Steel (1.5 mm)-Hairline Finish Landing Door Frame Finish - 1-3 Stainless Steel (1.5 mm) - Hairline finish |
| 17 | (V) SIGNALIZATION / FIXTURES DETAILS : Number of Car Operating Panel - 1 COP Faceplate Finish - Stainless steel - Hairline Finish Car Display - Dot - Matrix scrolling Display - vertical or as per OEM Call Register signal - Yes Floor Annunciator - Yes Landing Operator Panel type - Surface / Wall mounted Type LOP Faceplate Material - SS Hairline finish Landing Display Location - 1-3 LOP Call Register Signal - Yes Stainless Steel Braille Button - Yes Hall Lantern Faceplate Material - Stainless Steel - Hairline Finish Power Supply Hall Lantern Location - Right Side (VI)SAFETY DETAILS Over Speed Governor - Yes Door Protection - Infra red door Screen Counter weight Screen - Inbuilt Over Load Indicator - Yes Fireman Switch - Yes Automatic Rescue Device - Yes Battery Operated Emg Alarm Light - Yes Two Way Intercom with Press & Speak in CO - Yes |
| 18 | The lift shall be provided with and including the following: [a]Silver finish stainless steel on both sides , The wall inside the car should be silver finish stainless steel ,the front wall of the car should be silver finish stainless steel, the floor of the car should be jet black granite. The Car Operating Panel (COP) in side the car should be full height silver finish stainless steel face plate with round flush mounted ,wall buttons, car indicator should be colour LCD display, infrared sensors all along the height for car door with automatic rescue/leveling device (ARD) with suitable batteries, floor position digital indicators in car and all landing with call indicating light etc including necessary joist and beams for mounting machine in the headroom.[b] Fireman Switch[c] Automatic Rescue Device [ARD] during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. [d] Battery operated emergency light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with rechargeable arrangement for battery.[e] Adequate No. of LED light fitting for illumination in car cabin.[f] Provision of cross flow fan or other ventilation measures as per OEM in car cabin.[g] Provision of premium quality Jet black Granite stone slab of 18-20 mm thick as in flooring for lift car.[h] Nonstop button/ independent operation.[j] Over load warning indicator with both audio and visual type with overload protection/ tripping system having relays etc.[k] Provision of elevator voice (floor) announcement system.[l] Built in speaker [m] Front landing door with full vision glass panel with stainless steel mirror finish frame operations with a minimum time of 10 sec and up to a maximum time of 30 seconds Programmable. |
| 19 | [n] Stainless steel sliding doors with front opening for all Landings made of 16 gauge stainless steel sheet with Mirror finish with vision panel of size 200 X 800mm covered with 8mm thick toughened plain glass.[o] All the dimensions of the lift and connected items shall be designed in conformity with IS 14665 standards and the contractor shall submit the design drawing to Accepting Officer for approval before commencement of work. The body shall be stainless steel of 16 gauge with Mirror finish with 38mm dia stainless steel hand rail with hairline finish.[p] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS.[q] Specification plate with complete details[r] Full length display indicator panel. (s) Provision of suitable phase reversal relays to the controller to protect lift/ equipment against phase reversal, phase failure and low voltage.[t] Provision of Intercom.[u] Continuous earthing for machine and equipment [v] Steel Wire rope/belt of adequate size as per relevant IS and as per manufacturers specification.[w] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, car operational panel, governor, locks, power control and trailing cables complete all as per latest IS specifications/OEM. [x] Main drives and controls shall be high efficient and low power consumption.[y] Lift Shaft & loading frame should be MS and enclosed with 12mm Toughned glass and frame shall be interconnection with existing structure.[z] Lift ,Shaft & RCC Pit design, specifications, drawings shall be as per revalant IS code and got approved from Accepting Officer before placing order for procurement. |
| 20 | Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including taking down of existing earthing set complete all as specified. |
| 21 | S & F in repairs Earth continuity conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed. |
| 22 | S & F MCCB 415 V , 16 KA, 4 Pole, 63 Amps capacity complete all as specified and as directed. |
| 23 | Supplying, laying and testing XLPE insulated and PVC sheathed armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core 35 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down of existing cables complete all as specified and as directed. |
| 24 | Supply, Fabrication, installation and testing of LT panel out door type factory made CPRI Approved, water and vermin proof protection of size 1000mm x 1000mm x 500mm (over all demension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incoming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories and also including removing old existing one complete all as specified and directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 25 | INCOMNG (a) Copper strip busbar of 120 amps rated capacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos. (b) 4 pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links-01 No. (c) LED Neon indicator Lamp (RYB) with holder and fuse holder 230/250 volts, AC-01 set (set of three) Make:- Legrand/L&T/Schneider. (d) Digital Ammeter of range (0-100) Amps, flush mounting type with CT's of ratio 100/5 and selector switch - 01 set. OUTGOING (a) 4 pole MCCB 40 Amps including all fixing accessories with both ends lugs-02 Nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel of size 200mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT-01 No. Please Enable Macros to View BoQ information |