| 1 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4Cx10 Sq. mm Armoured Al cable (9.1.32) |
| 2 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) (14.16.1) (Rex, Dura line) |
| 3 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(Make-B class -Jindal/TATA/QST) - ISI Marked |
| 4 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable trench etc as required. |
| 5 | Supplying and laying of one number XLPE insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 4Cx10 Sq. mm cable size in the existing RCC/ HUME/ METAL/DWC pipe etc as required.((Make-Polycab/Universal/Havells/KEI/Finolex) |
| 6 | Supplying and laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size in loose for connection etc complete as required.(Make-Polycab/Universal//Havells/KEI/Finolex) - ISI Marked4Cx10 Sq. mm Armoured Al cable |
| 7 | LED Street light fixture, powder coated pressure die castaluminum body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 90 watt (make-Wipro/Philips/Havells/Cromptor/LT/Polycab) (8.12.14) |
| 8 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 6 Mtrs. height made from 3 mm thick HR Steel plate having effective bottom dia of 130 mm & effective top dia of 70 mm complete with window sleeve type cover arrangement at a height of 0.5 Mtrs from the base for cable termination block welded on both ends etc. and galvanized base plate of size 200 mm x 200 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination. (Make-Valmart/Bajaj/UTKARSH)Each pole should have followingSupply & fixing 1 no. 6 mm thick laminated mounted sheet inside the window i/c providing mounting arrangement etc complete as reqd.Supply and fixing 63 amps. terminal block suitable for 1.1 KV grade 4CX 16 sq. mm Armoured cable - 4 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length on the existing laminated sheet. Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 No., earth stud -1 No., welded at suitable height one nos washers, springs washers & nuts. Provision on suitable height for fixing of additional bracket Cable supports clamps suitable for 4x10 /4 x 16 sq. mm cable. |
| 9 | Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size 450 mm (L) X 450mm wide and 1200mm deep i/c excavation of rocky earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia 1350 mm long (approx.) 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia -1800mm (approx.) 8 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing 40 mm dia (O.D.) DWC, HDPE pipe of 0.3 Mtrs. length for cable entry & exit as reqd. as per annexure 1 |
| 10 | Supplying and Fixing 4 Nos. 20 mm dia. X 600mm long GI foundation J Bolt (EN8 grade) with nuts,washer including 2 Nos. template of 3 mm thick size 200mmX200mm with 4 Nos. 24mm dia holes to match with PCD of Pole base plate as reqd. |
| 11 | Fabrication, supplying & fixing of single/double/tripple over hang galvanized arm bracket made out of Suitable dia & 500 mm to 1500 mm long & top tube with suitable dia etc complete as required.(Design as per approved sample). |
| 12 | Supplying and drawing following size of PVC insulated copper conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.(Make-L&T/Finolex/National/Polycab/Grandlay)3 core 1.5 sq.mm 1.1 KV grade Please Enable Macros to View BoQ information |