| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 6 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 7 | Centering,shuttering inluding strutting,proping etc. & removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 8 | Centering,shuttering inluding strutting,proping etc. & removal of form for Suspended floors, roofs, landings, balconies and access platform.Hight up to 3.5 m |
| 9 | Centering,shuttering inluding strutting,proping etc. & removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.Hight up to 3.5 m |
| 10 | Centering,shuttering inluding strutting,proping etc. & removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.Hight up to 3.5 m |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level and above.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Brick work with first class brick (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Brick work with first class brick (non modular) bricks of class designation 15 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 14 | Brick work first class brick (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 15 | Brick work first class brick (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes) in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (11.14a+b+c+d+e)With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 17 | Earth work in cutting or in embankment in ordinary soil, excavation to be in the regular pits not exceeding 0.5m in depth and earthwork in embankment to be in 20cm layers, including ramming and dessing the surface to requied levels & slopes & also uncluding 1.5 lift & 30m lead. The earth from cutting to be used in making embankment or to be deposited as spoil banks with 30m. Distance as directed by the enginee incharge (Including Royalty). & Also including cartage up to 8 Km From out side the site of work & including cost of earth watering, dressing & comppacting the soil to achieve 95% proctor density. |
| 18 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 19 | 12 mm cement plaster of mix (1 cement: 4 coarse sand) |
| 20 | 12 mm cement plaster of mix (1 cement: 6 coarse sand) |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix1:6 (1 cement: 6 coarse sand) . |
| 22 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). |
| 23 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 15 mm wide and 15 mm deep groove |
| 24 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover . |
| 25 | Providing & Fixing ball bearing for rolling shutters |
| 26 | Providing and fixing unplasticised -PVC pipe clips of approved designto unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. complete 110 mm |
| 27 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 28 | Construction Drain size 150mm x 150 mm along Apron 90 cm wide with 25mm thick cement concrete 1:2:4 over 75mm thick base concrete 1:4:8 including brick work in 1:4 cement and coarse sand mortar and 12mm thick plaster in 1:4 cement and coarse sand mortar complete in all respect etc. |
| 29 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. |
| 30 | 25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand). |
| 31 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 32 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete size of tile 600x600mm |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete. (Hot finished welded type tubes kg) |
| 34 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as required. |
| 35 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as required. (Fabrication of Z Section steel windows) |
| 36 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 37 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) 300x16 mm |
| 38 | Providing and fixing 250x10 mm ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 39 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 150x 10 |
| 40 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125 mm |
| 41 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows clerestory windows, all complet with 4.0 mm thick glass panels |
| 42 | Washing Brick walls 3 % HCl 2% Alum and 1 % soap solution |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 44 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) plaster on ceiling including chipping of CC /RCC surface before plastering in cement mortar of mix 1:3 (1 cement : 3 Fine sand) (Not Less than in 1.25 FM |
| 45 | White washing with lime to give an even shade New work (three or more coats) |
| 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 Sqm over existing cement paint surface. |
| 47 | Providing and applying putty with approved quality material of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 48 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. |
| 49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc complete. |
| 50 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 51 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B. |
| 52 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 53 | Supply and fixing of power plug with 15 Amp./250 Volt flush type universal switch and 5 pin 15 A/250 V flush type universal socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. |
| 54 | Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required. |
| 55 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, two way modular switch,modular plate, suitable size GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. . |
| 56 | Wiring point for fan/fress air fan with 1.5 sq. mm FRLSH PVC insulated multistrand single core copper conductor cable as earth wire drawn inside the conduit, modular switch and ceiling rose on 3 mm, thick phenolic laminated backelite sheet etc. comkplete in all respects, as directted including matching colour wash. |
| 57 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 58 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 5 - 32 amps.Cat. A |
| 59 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductor |
| 60 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductor . |
| 61 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conducto.r |
| 62 | Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with 2 number 6 sqmm FR PVC insulated multistranded copper conductor . |
| 63 | Supply and wiring of submain 2 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with 2 number 6 sqmm FR PVC insulated multistranded copper conductor . |
| 64 | Supply and wiring of submain 1 number 16 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with 2 number 10 sqmm FR PVC insulated multistranded copper conductor . |
| 65 | Supply & Fixing of LED tube light with batten suitable for up to 1x22 watt LED tube ligth complete including tube etc. on surface complete in all respect. Cat AAA |
| 66 | Supply and Fixing of recess/surface mounting round 24 watt to 32 watt LED Down lighter having powder coated die cast aluminium housing with extended heat sink and diffuser/Reflector and driver set complets in all respect. |
| 67 | Supply and erection of AC 1200mm Sweep. 230/250 Volts, 50 Hz ceilling fan without regulater standard down rod, blades including connection etc. complete as required as per direction of E/I |
| 68 | Supply and Fixing of Electronic Fan Regulator (Modular) 120-280 V ISI marked on the existing switch board icluding makisng connections, required material labour T&P etc.for proper completion of work to the satisfaction or engineer incharg of work |
| 69 | Supply & Fixing of hexagonal /round G.P fan box of approved make made up of 1.0 mm thick ISI marked G.P Sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shttered type with 0.5 mm GP. Sheet made upper & lowe cover screwed fitted with 300 mm round zink coted M.S. bar X 12 mm & brand name should be exbosses fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, albour, T&P etc, required for prper comletion of the work. |
| 70 | Supply & Fixing of 3 mm thick backlite sheet cover round/hexagonal type for fan box complete with all material labour T&P as per direction of E/I (M.R.) |
| 71 | Supply and fixing of flush/surface mounting distribution boards with additional metal door without MCB complete in all respects. 6 Way TPN |
| 72 | S/F of danger board fabricated from 10 gauge M.S. sheet as per I.E. Rules |
| 73 | Supply and Erection of 300mm sweep size metal Exhaust fan on existing hole complete in all respect. As per (M.R.) |
| 74 | Supply and fixing LED street light fitting having die cast aluminiumbody and fiffuserwith driverset suitable for 75 to 90 watt. Confirmingto IP 65 and above Protection complete in all respect. |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes. |
| 76 | Supply & fixing of UPVC S.W.R pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring lubricant & UPVC SWR cuplar confiming to IS-14735, also including excavaiton of trenches, cutting of walls & holes & reparing the walls, floors & refilling the trenches as before but excluding supply & cost of other fittings such as elbow, ben tee & Y-tee including supply of all material, labour & T&P required ofr proper completion of the work 110 mm OD |
| 77 | Supply & fixing of UPVC S.W.R Plain Y confirming to IS 14735 110mm |
| 78 | Supply & fixing of UPVC S.W.R Plain Bend 110mm confirming to IS 14735 |
| 79 | Supply & fixing of UPVC S.W.R pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring iubricant & UPC SWR cuplar connfiming to IS-14735, also including excavaiton of trenches, cutting of walls & holes & reparing the walls, floors & refilling the trenches as before but excluding supply & cost of other fittings such as elbow, ben tee & Y-tee including supply of all material, labour & T&P required ofr proper completion of the work 90 mm OD |
| 80 | Supply & fixing of UPVC S.W.R Plain Bend 90mm confirming to IS 14735. |
| 81 | Supply & fixing of UPVC S.W.R Plain Y confirming to IS 14735 90 mm. |
| 82 | Supply & fixing of UPVC S.W.R nahani trap size 100/75mm confriming to I.S - 14735 selb cleaning design fixed in PCC 1:2:4 and supply and fixing of 125mm Dia CP brass jali. |
| 83 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 84 | Providing and fixing water closet squatting pan (indian type W.C. pan) with 100 mm sand coast lron P or S Trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device ( hanble lever) confirming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever tequired : White Vitreous china Orissa pattern W.C. pan of Size 580x440 mm with integral type foot rests. |
| 85 | Providing and fixing water vitreous china wash basin with C.I. Brackets painted white, 15 mm C.P. brass pillar tape, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattem including, cutting & marking good the walls wherever required. a) white Vitrecous china wash basin size 630x450 mm vith a pair of 15 mm C.P. brass pillar taps |
| 86 | Providing and fixing C.P. brass long body bib cock of approved quality confiming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 87 | Providing and fixing C.P. brass angle valve for basin mexer and gyser points of approved quality confiming to IS 8931 15 mm nominal bore |
| 88 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 89 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20mm dia nominal bore |
| 90 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screwa and washers complete. |
| 91 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 92 | Providing and fixing PTMT towal rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour, 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm weighing not less than 170 gms |
| 93 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 94 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 95 | Providing and Fixing PTMT bottle trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm form the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260gms |
| 96 | Providing and laying cement cincrete 1:5:10 (I cement : 5 Coarse sand : 10 graded stone aggregate 40mm nominal size) All-round S.W.R pipe including bed concrete as per standard design. 100 mm dia |
| 97 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete 50 to 80 mm nominal bore |
| 98 | STTC of fire extinguisher Supply and fixing of C02 Type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and laboutfor proper completion of work. |
| 99 | Supply and Fixing of Fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completion of work |
| 100 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes) in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 101 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 102 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture. |
| 103 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 104 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitablemethod prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. For 300 mm dia. |
| 105 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 106 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 107 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer in- charge. |
| 108 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer in-charge. |
| 109 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 110 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations consolidation each deposited layer by ramming and watering lead up to 8km. total area of electic sub station= 2400 sqm plinth levek height =0.45 m volume of earth filling=1080 cum |
| 111 | Brick on edge pavement with straight over burnt bricks on patries with brick laid dry joints filled with sand including preparation to base to proper slope and its ramming and spreading layer of 1 cm. depth of local sand over the subgrade and i/c supply of all meterial labour tool and plants etc. required for proper completion of the work. |
| 112 | Construction of granular sub-base by providing coarse graded material, spreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401, MORT&H - 401. (with coarse graded Material and grading - I as per Table 400 -2 of MORTH 401.) |
| 113 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. Please Enable Macros to View BoQ information |