| 1 | Civil work Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Providing and laying Stone soling hand packed incl ramming, watering etc complete job |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (Back filling) |
| 5 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. . All works above plinth level upto floor V level |
| 8 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations: footings, bases of columns etc. for mass concrete. |
| 11 | Suspended floors, roofs, landings, balconies and access platform. |
| 12 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Columns, pillars, piers, abutments, posts, and struts. |
| 14 | Stairs (excluding landings) except spiral staircases. |
| 15 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation/ plinth & superstructure above plinth level upto floor five level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 18 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in superstructure above plinth level upto floor V level Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class deodar wood |
| 20 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. First class kail wood (35mm Thick) |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick First class kail wood |
| 23 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.First class kail wood 35 mm thick |
| 24 | Providing and fixing 35mm thick wire guaze shutter using galvanized M.S wire gauze of average width for aperture 1.4m in both directions of wire dia 0.63mm for door,windows and clerestory windows with ISI marked M.S pressed butt hinges bright finish of required size mecessary screws as per directions of EIC First class kail wood |
| 25 | Providing and fixing 3.5mm thick float pans including cost and fixing wooden fillets/ beeding of required size and shape with nail incl all carriage complete |
| 26 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 27 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete a) 200x10mm |
| 28 | b) 100x10mm |
| 29 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. A) 150mm |
| 30 | b)100mm |
| 31 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper |
| 32 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive and other allied fixing material to fix it properly on base complete job |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm |
| 34 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm |
| 36 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 37 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (18mm Thick) |
| 38 | Providing edge moulding to 18 mm marble stone /granite stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (Granite Work) Double moulding |
| 39 | 6 mm cement plaster of mix :1:6 (1 cement: 3 fine sand) |
| 40 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 41 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand). Complete job |
| 42 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2mm Thick) |
| 43 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 44 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats) |
| 45 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 46 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. |
| 48 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 49 | Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointed with cement mortar 1:3 (1cement: 3 fine sand) and curing complete |
| 50 | Carriage of materials by mechanical transport from source upto site of work including loading, unloading and stacking Carrage of coarse aggregate for avg lead of 35 kms |
| 51 | Carrage of fine aggregate for avg lead of 85 kms |
| 52 | Carrage of bricks for avg lead of 100 kms |
| 53 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete. |
| 54 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 55 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts,leads and carriages complete job |
| 56 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 57 | Providing valleys of 90cm wide overall in plains G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G I. limpet and bitumen washers complete.1.25mm thick with zinc coating not less than 350gm/m2 |
| 58 | Providing and fixing plained eaves boarding. wood 2nd class Deodar wood 300x40 mm (nominal size) complete job |
| 59 | P/F 12mm thick imported wood as soffit including cost of frame work of KD wood underneath of required size as per directions of EIC including cost of primer and paint one or more coats involving all cost of labour,carriage, material , scraffolding cjob (Item to be executed as per directions of EIC) |
| 60 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions with vision glass panels of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalization &drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanized / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerin-charge. Theitem also includes the cost of all mock ups at site, cost ofAll samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted onstructural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accredited by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity oftesting on the basis of cost of the work, cost of the test and importance ofthe work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditationbody which operates in accordance with ISO /IEC 17011 and accredits labs as per ISO/ IEC 17025.1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static airpressure test (1.5 times design wind pressure without any failure) as perASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testingmethod for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 61 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment |
| 62 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.30.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 63 | Sanitary works SUB HEAD -I :SANITARY FIXTURES Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. W.C. pan with ISI marked white solid plastic seat and lid |
| 64 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 65 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 66 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. White glazed fire clay kitchen sink of size 600x450x250 m |
| 67 | providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge a) 32 mm dia |
| 68 | 40 mm dia |
| 69 | Providing Sink mixer (wall mounted) with 170mm long swivel spout connecting legs and wall flanges((CERA Cat. No. OCEAN F3002501 or approved equivalent) . |
| 70 | Providing and fixing Braided Hoses with Two 15mm CP Brass Nuts & Rubber Washers Without Nipple (Suitable for Geysers and basins) of approved make :a)45 cm length 15 mm nominal bore |
| 71 | Providing and fixing toilet paper holder : CP Brass |
| 72 | Providing,Fixing,testing and commissioning of CP brass twin coat hook with concealed screws. |
| 73 | Providing and Fixing Health Faucet 15mmdia with CP flush pipe, CP nozzel hook complete including CP flange etc. |
| 74 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 75 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 76 | Providing and fixing horzontal/vertical Hot water geyser made of MS body with copper jacket inside with necessary inlet, outlet, drain, overflow, vent and all safety accessories etc. complete including cutting and making good the walls, wherever required. 15 lit for Kitchen(For Kitchen And pantry.) |
| 77 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 78 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms |
| 79 | SUB HEAD -II :SOIL, WASTE, VENT & RAIN WATER PIPES Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug,bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer's specifications and making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) Inclouding cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around soil and waste pipes under floor, including shuttering and centering for: 75mm outer dia. |
| 80 | 110mm outer dia. |
| 81 | Insulation wire on pipe is use over all length of pipe as per requirement. Providing and fixing thermal insulation over pipes/fitting/Trap Etc as req. in exposed/chase with 32 mm thick approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per manufacturer's specifications and finishing it with 6mm thick rough plaster of 1:3 mix (1 Portland Cement : 3 hard settling cement compound)(Make-K-Flex,Eurobatex,Vidoflex.) 75mm outer dia. |
| 82 | 110mm outer dia. |
| 83 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :100mm dia pipe |
| 84 | Providing and fixing multi inlet uPVC floor trap with minimum 50mm water seal of self cleaning design with 110 mm outlet consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc, complete including cost of cutting and making good the walls and floors wherever required and as directed by Engineer in charge. (The inlet diameter shall be 32mm, 40mm or 50mm as per site requirements) |
| 85 | Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge. 32 mm OD |
| 86 | 40 mm OD |
| 87 | 50 mm OD |
| 88 | Providing and fixing SS grating with frame including fixing to the floor with cement mortar.100mm dia |
| 89 | Providing and fixing 110mmx50mm outlet. UPVC floor drain consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc all complete as per specifications and direction of Engineer-In-Charge. |
| 90 | Providing & fixing of cast brass clean out plug(floor/ceilling) with suitable insert keys for opening in: brass cap, male threaded joint with threaded G.I socket fixed to HCI soil pipe or C.I.(LA) pipe joints as required complete in all respects. 110mm outer dia. |
| 91 | SUB HEAD -III :INTERNAL WATER SUPPLY PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast Concealed work including cutting chases and making good the wall. 16x2 mm outer dia pipe |
| 92 | 20x2 mm pipe |
| 93 | 25x2.5 mm outer dia pipe |
| 94 | 32x3 mm outer dia pipe |
| 95 | PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast Exposed on wall/terrace 16x2 mm outer dia pipe |
| 96 | 20x2 mm outer dia pipe |
| 97 | 25x2.5 mm outer dia pipe |
| 98 | 32x3 mm outer dia pipe |
| 99 | Insulation on pipe is use over all length of pipe as per requirement. Providing and fixing thermal insulation overr pipes in exposed/chase with 32 mm thick approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per manufacturer's specifications and finishing it with 6mm thick rough plaster of 1:3 mix (1 Portland Cement : 3 hard settling cement compound)(Make-K-Flex,Eurobatex,Vidoflex.) 25 mm dia |
| 100 | 32 mm dia |
| 101 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 102 | 20 mm nominal bore |
| 103 | 25 mm nominal bore |
| 104 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 105 | SUB HEAD -IV : EXTERNAL STORM WATER Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. Metre |
| 106 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating cement Brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :180x150 mm size P typeWith Sewer cement Brick conforming to IS : 4885 |
| 107 | Providing, laying, jointing and commissioning of PVC pipe As/IS:15328 with pussfit joint with solvent including testing of joints etc. complete as directed by Engineer in charge.(inclouding allround cement concrete).150 mm dia.pipe |
| 108 | Constructing cement Brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cms and 45 cms deep including CI cover with frame (Light duty) 610x455mm internal diamesions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg) With common Cement Bricks, Size (Inches): 24 x 8 x 4 |
| 109 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated asper IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimun cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufacture\\"s permanent identification mark to be visible even after fixing \\" incluting fixing in manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size )complete as per design. |
| 110 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc complete.For pipes 250 to 300 mm diameter |
| 111 | Constructing cement Brick masonry road gully chamber 50x45x60 cm with cement Brick in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common Cement Bricks, Size (Inches): 24 x 8 x 4 |
| 112 | SUB HEAD - V : FIRE-FIGHTING SYSTEM FIRST AID HOSE REEL:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. (30m) |
| 113 | MS PIPE:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100 mm |
| 114 | 80 mm |
| 115 | 25 mm |
| 116 | BUTTERFLY VALVE:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 100 mm |
| 117 | 80 mm |
| 118 | NON-RETURN VALVE:Providing installation testing and commissioning of non return valve of following sizes conforming to IS: 5312 complete with rubber gaskets, GI bolts, nuts, washers etc as required. 100 mm |
| 119 | 80 mm |
| 120 | FIRE BRIGADE TWO WAY INLET:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 Way- 100 mm dia M.S Pipe |
| 121 | AIR VESSEL:Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 122 | Providing and fixing Brass/Bronze lever operated Ball Valve of full flow with stainless steel ball with setting and gland of superior quality having minimum pressure of 20 Kg/cm² |
| 123 | Providing and fixing of Polyethelene Six layer (minimum) water tank on terrace of capacity 2000 Ltrs, IS:12701. |
| 124 | Providing of interconnections between 5 No. of water tank at the bottom so that all the tanks acts as one reservoir by way of fixing tank nipple, ball valves of required dia and other accessories required to complete the job. |
| 125 | TERRACE PUMP:(A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520(C) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti-vibration pads etc. 450 lpm at 35m head |
| 126 | ELECTRICAL PANEL:Fabrication, Supply, Installation testing and Commissioning of Electrical Control panel of Cubical construction floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switch gears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for terrace pumpset with following incoming and outgoings, suitable for operation on 415V, 3 phase, 50Hz AC Supply with enclosure protection class IP42 as required:Incoming:- 63A, 25KA 4 pole MCCB, Ics-100% icu rating- Digital Voltmeter 0-500V with selector switch- Digital Ammeter 0-100A with selector switch and CTs etc- LED type RYB Phase indicating lamps, ON, OFF, trip indicating lamps- Set of copper Bus Bar 100AOutgoing:- 24-32A MPCB with suitable HP fully automatic Star/Delta Starter with Overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation |
| 127 | POWER CABLE:Supplying and Laying of one number XLPE insulated power cable of 1.1 KV grade of following size: i) 25 Sq. mm x 4 Core Aluminium Armoured |
| 128 | ii) 2.5 Sq. mm 12 Core Copper Armoured |
| 129 | iii) 2.5 sqmm x 3 core Copper armoured |
| 130 | Supply and Making end Termination with Double Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required: i) 4C X 25 Sq.mm |
| 131 | ii) 12 C X 2.5 Sq.mm Copper Armoured |
| 132 | iii) 3 C X 2.5 Sq.mm Copper Armoured |
| 133 | PRESSURE GAUGE:Providing and Fixing of Pressure Gauge of 100 mm dia |
| 134 | PRESSURE SWITCH:Providing and Fixing of Pressure Switch (for operation at 0-25 kg/cm²) with required fittings and accessories complete. |
| 135 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangements and watering pipe etc. with charcoal/ coke and salt as required. |
| 136 | Supplying and laying 25mm x 5mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connections/terminating with G.I. nut, bolt, spring washer etc as required (Jointing shall be done by overlapping and with 2 sets of G.I nut and spring washer spaced at 50mm) |
| 137 | Supply and fixing of Rockwool insulation of 75mm thickness minimum 30-50 kg/m3 density with thermal conductivity of min K-0.04 W/mk at minus 25 degree centigrade. |
| 138 | FIRE EXTINGUISHER:Providing and Fixing with Brackets/ Supports etc. Wall/ Floor Mounted Fire Extinguisher as per detail given below: i) ABC Powder Type (Stored Pressure) Fire Extinguisher 6Kg Capacity ISI Mark IS:15683 Suitable for class 'A', 'B', & 'C' Fire consisting of welded cylinder, Squeeze lever discharge valve fitted with pressure indicate gauge, internal discharge tube, discharge hose with nozzle, suspension bracket, duly charged with ISI Marked Mono Ammonium Phosphate base ABC Powder Conforming to IS: 14609 and Pressurized with nitrogen gas, suitable for Operating between -10°C to +55°C IS: 15683 Complete in all respect. |
| 139 | ii) Supply and installation of CO2 fire extinguishers consisting of Aluminium cylindrical body, (bearing IS: 15683 marking) squeeze lever discharge valve fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS 934 finished externally with red enamel paint and linked to wall with brackets with rawl plug/dash fasteners complete with internal charge. The Carbon-di-oxide filled in the cylinder must be as per IS 15222. Capacity 4.5 kg (I.S.I marked) |
| 140 | Providing, installing, testing and commissioning of Ceiling Mounted Automatic Fire Extinguisher (Self Activated Type) suitable for automatic operation in the event of fire by temperature sensitive bulb/fusible element activation, complete with extinguishing agent, ceiling mounting clamp/bracket and all accessories as required. The extinguisher shall be pressurized stored pressure type, ceiling suspended type, capable of automatic discharge upon attainment of predetermined operating temperature. The extinguisher shall conform to relevant provisions of IS 15683 latest edition for portable fire extinguishers and other relevant Indian Standards applicable to fire extinguishing systems. (5 Kg Automatic Modular ABC Type) |
| 141 | Supply and fixing of illuminated Fire exit signages. This sign may be used to indicate all exits which can be used in the event of an emergency. It shall be accompanied by an arrow as per IS-12349(1988) standards. |
| 142 | Electric work (Internal electrification) Wiring for Light point/Fan point/Exhaust fan/Bell point with (PNF) 3x1.5 sq.mm FRLS-11 PVC insulated Multi strand Copper conductor single core cable, (Havells/Anchor/iq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 125mm) with 01 No.of 6 Amp Modular Switch, Modular Plate, Cover in front & suitable Gl box ete ISO/IEC Certified/Schneider/Havells/ Legrand/Anchor roma plus/ABB/Eq. Make & items shall be approved before execution of work by SDO (Group A) |
| 143 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.ISO/IEC Certified of Havells/Legrand/Anchor/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO. |
| 144 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-IH PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make) |
| 145 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required, ISO/IEC Certified/Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO. |
| 146 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.min FRLS-IH PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq. Make) |
| 147 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus/Schneider/ABB/Eq.Make & shall be approved before execution of work. |
| 148 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of F-RLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ fq. Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) - 2 X 16 sq. mm+1X 6 sq. mm earth wire |
| 149 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of F-RLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ fq. Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) - 2 X 10 sq. mm+1x6 sq. mm earth wire |
| 150 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of F-RLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ fq. Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) - 2 X 6 sq. mm 1 X 4 sq. mm earth wire |
| 151 | 25sq mm + IX 2.5 sq. min earth wire |
| 152 | Supply Fixing Testing and Commissioning of 6Amp to 32Amp Rating SP.240v, C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections. ( &T Siemens/Legrand/Havells/ABB/Eq. Make) |
| 153 | Supply/Fixing/Testing and Commissioning of following rating. Double pole. (P+N) 240 V, C Curve 10KA,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq Make) - 63 Amp. |
| 154 | Supply/Fixing/Testing and Commissioning of following rating. Double pole. (P+N) 240 V, C Curve 10KA,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq Make) - 40 Amp. |
| 155 | Supply/Fixing/Testing and Commissioning of following rating. Double pole. (P+N) 240 V, C Curve 10KA,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq Make) - 32 Amp. |
| 156 | Supplying and Fixing of MCB way 6-way (4+24). horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V. on surface/recess, complete with tinned copper bus bar, neutral bus bar. earth bar. din bar, interconnections. powder painted including earthing ete, as required. (L&T/Siemens/Legrand/Schncider/ABB/Eq Make) |
| 157 | Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95,THD<10% CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make. |
| 158 | Supply/Installation Testing & Commissioning of 1 ft LED Bed Light Mirror Light of Havells/Wipro/Halonix/ Eq. Make as duly fitted on walls including making of necessary Connections & sample shall be approved by EIC. |
| 159 | aling & 11xing of IK08 IP-66 protected high power 11 D 50 Watt flood light with single piece Pressure diecast aluminum housing, toughened glass with suntable lenses on 11 D to achieve various beam angles, of high power watt each Integrated potted driver as a unique BIS R number having lattuser 11D of 3 to 5 efficiency more than 85 and in compliance to BIS certified and Trade mark certificate The System level Luminaire efficacy -125 lm/wt LFD driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @-300 V AC and Auto resetting Safety Power Factor 0.95. THD(1)<10%, driver current 750mA driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector. Surge Protection Min 4KV internal and 10KV external but inside driver compartment. System life of 50000 Burning hours with 70 of Initial Lumens maintained. CRI 70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved Imbossing Screen printing on die cast housing to allow traceability authenticity Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OFM shall be submitted. All as per pre approved by lingineer in charge. For additional technical parameters of products/ work. refer Annexure \\"A\\" attached with this BSR-High Power LED Flood Light Minimum lumen output 6200 Im of Havells Crompton Plulips/Halonix/Equivalent Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning handing over of site to intending department |
| 160 | Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9. Service Value including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete. USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge. |
| 161 | Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make.(Min 1-Star) |
| 162 | ply Laying/Connecting and Commissioning of 90 sq.mm 3.5-Core PE/PVC insulated and steel armored 1.1 KV grade Aluminum able of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench (Material to be approved before execution) |
| 163 | Supply/Installation Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel dully Painted with powder coated paint,dust protected earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make (1) Normal Incomer: a) 200 Amp-4-Pole 36kA C-CURVE MCCB with extended terminals Havells L&T Legrand Schneider Make as approved-01 No. b) 400 Amps TPN Al. Bus Bar Scl=01 Set. Digital Voltmeter Ammeter .CT Coils with Selector Switch & Phase indicator Set Outgoing: (1) Normal outgoing for Heating AC Lighting Inverter ete load a) 63-Amp DP MCB-04 No for Heating Sub-main (b) 40-Amp DP MCB-04 No for Lighting Machine Sub-main (c) 32-Amp DP MCB-04 No for inverter Sub-main |
| 164 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man-hole cover for the above. Including cost of 20MM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 165 | installation testing, &commissioning of 50 KVA 3-Phase RVO controlled VOLTAGE Stabilizer of Approved brand with llowing SPECIFICATIONS: INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P) OUT PUT VOLTAGE: 400Volts+ 1%(230VAC) (3) Winding Material Insulation: 99.97% PURE COPPER WOUND FIBER GLASS (4). IN DOOR TYPE (5). COOLING OIL IS 335 (6).MICRO CONTROLLED TRUE RMS Based LCD display 6 (7). Protections are Over Load COPPER wound of/Chinar/ Electric Field/Alba/AE Cosco/Eq.make ete ISI/ISO certified for smooth functioning/ constant voltage supply having Technical Specifications: Input voltage = 156-415 volts & output voltage 415 volts+ - 1% Buck Boost Transformer Copper wound 99.9% OIL Immersed COOLING OIL High cut/Low Cut/Time delay/Over Cut through Micro Control and Spike Protection including Carriages installation charges, testing & taxes complete job alongwith servo bypass switch of adequate rating. |
| 166 | Supply/Installation/Testing & Commissioning of 10KVA/192V On-Line UPS model DXRT system with 3 phase input and 1 phase output built in OVCD, 1.0 pf, VFI 17 technology, 2-13A DC charger, complete with EnerRocket 1 make 16 nos. 12V/150AH SMF with MS Battery Rack, Battery Link Set and Installation.Eaton/Eq.make |
| 167 | Supplying, Installation. Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS: 15683) and dully certified |
| 168 | Supplying. Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) suitable for 'B' and 'C' class fires - inflammable liquids, gascous fires like L.P.G. and each acetylene, and electrical fires |
| 169 | Construction of LT Network ST Pole 8m Long (410-SP-15) |
| 170 | Cement bottoming 1:2:4 mix as per Standards 0.45 cum/pole |
| 171 | GI Mukey for Shackle Insulators with bolt of (50x6)mm clamp |
| 172 | 16 kN Polymer Shackle Insulators |
| 173 | Danger Boards with anticlimbing devices |
| 174 | Painting of Poles |
| 175 | Earthing of Poles |
| 176 | Nuts and Bolts of Sizes |
| 177 | Labour Charges for Normal Terrain complete job |
| 178 | SITC of LT 3-Phase Prodigy meter complete job Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail