| 1 | H.S.R. Item |
| 2 | Provision for Providing and fixing CI pipes, Specials and DI Sluice, NRV of required make i.e. IVC /VAG to be installed inside pump chamber for making connection with proposed pumping machinery complete in all respect. |
| 3 | Supplying, erection, testing and commissioning or Horizontal motor pumping set or Raw Water having head 20.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) |
| 4 | Supplying, erection, testing and commissioning or Horizontal motor pumping set or Raw Water having head 12.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) |
| 5 | Supplying, erection, testing and commissioning or Horizontal motor pumping set or CLear Water having head 40.00 m as requirements of discharge in LPM and power capacity in BHP Make: KSEB, CRI, Kirlosker, Crompton Greeve, Lubi) |
| 6 | Design, supply, installation, testing and commissioning of cubical type L.T. panel suitable for 630 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 16 SWG thick for frame work and covers, 3 mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for approved shades, having 630 Amp. Capacity extensible type TPN copper Bus bar for high conductivity, DMC/SMC bus bar supports, Panel Manufacturer shall have CPRI test certificate for short circuit with stand capacity of 31 MVA for 1 Sec. bottom based channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common tinned copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium bus bar and control wiring with 2.5 sq. mm FRLS insulated copper conductor S/C Cable, Cable alleys, Cable gland plates in two half, i/c providing following switch gears etc. as required. The design and drawing of panel board will be approved from Engineerin-Charge before installation at site. Outgoing for pumping machineries and fully automatic ATS starter with following items: Incomer MCCB 630 Amp. 36 KA Ics 4 pole, complete with spreader links, phase barriers and ROM of make : LandT D Sine, Schneider NSX compact, Siemens 3 VL, Digital Multi Functional Meter with CT of 400/5 Amp. and RYB indicator for phase identification of Make :LandT Vega Series or equivalent in ABB and Siemens, Schneider, Siemens, ABB Outgoing Feeder 1 No. 630 Amp. 36 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine. Schneider NSX Compact, Siemens 3VL, for existing feeder (existing load)(Including third party inspection from any Govt. Agency ( as approved by Engineer-In-Charge) make as per Haryana DGSandD rate contract approved manufacturer. i) 1 No. MCCB 630 Amp. 25 KA Ics 3 Pole, complete with spreader links, phase barrier and ROM of Make : LandT D Sine, Schneider NSX Compact, Siemens 3VL.ii) 3 No. Inline contractor for fully automatic ATS starter AC 3x265 Amp. of make MNX 70 of LandT or equivalent in ABB/Siemens.iii) 1 No. fully automatic ATS starter for motor with inside delta connection min 70A for 6 wire Connection Cat No. EMX3- 0023B-411 of LandT or Equivalent model 3RW44 of Siemens/PSTB of ABB.Note :- Suitable Size of Semiconductor fuse shall be used for Backup protection of fully automatic ATS starter Design, supply, installation, testing and commissioning of APFC Panel of 14.50 KVAR of suitable steps capacity suitable for operation on 415 plus 5% volt, 3 phase, 50 Hz, AC supply having heavy duty static capacitors (Without oil) of suitable rating complete with TP MCCB of 630 Amps. 36 KA (Ics=100%) capacity with L.T. Panel with adjustable thermal magnetic bases release for over current and short circuit protection as incomer of the panel, of suitable step microprocessor based power factor controller, duty contractors for each capacitors protected with suitable rating MCCBs of minimum 18 KA ICs breaking capacity having thermal magnetic release for over load and short note circuit protection, cooling fans for panel and Digital multifunction meter, Class-1.0, indicating lights, earthing the panel etc. as reqd. The Panel should be manufactured with 2mm thick CRCA sheet duly powder coated etc. The APFC Panel shall be in continuous with L.T. Panel. Makes of Capacitor/ contactor/ MCCB/ APFC Controller : LandT/ Siemens/ ABB complete in respect to the satisfaction of Engineer-In-Charge. (For run the squirrel cage induction type energy efficient electric motor of 1440 RPM, 3 phase 50 Hz as per specification of efficient class IE-3 to run the raw water pump having discharge 8100 LPM with 65 mtr. Head) (Including third party inspection from CEIL). |
| 7 | Provision for HT metering Panel with GO switch, H Pole VCB / ACB equipped with 6 No plus 6NC auxiliary contact 240 Volt, AC Shut release, service position micro switch 240V AC motor ACB will be horizontal draw out type and all other required electrical items. |
| 8 | Less Credit of Old Bricks bat |
| 9 | Less Credit of Old Bricks |
| 10 | Less credit of old Pumping Machinery .. |
| 11 | Less credit for old steel , scrap , Pipe etc. |
| 12 | Less Credit of old 600 mm i/d RCC Np2 Inlet Channel 4015 Mtr. And Brick Sluice Valve Hodies From Jui Feeder to 1st Existing Water Works Village Chang |
| 13 | Dismantling Concrete : Reinforced cement concretewith cleaning and straightening and cuttingofbarsifrequiredforRCCshaftincluding dome of OHSR upto height of 120 ft. above ground level.Providing arrangement of wooden/steel scafolding to dismentalling the RCC OHSR by manual labour/mechanically ways etc.Segregating and cutting the old steel bars from the dismentalled RCC OHSRRemoving of dismentalled RCC material / malba within the premises of 1st water works ChangRemoving the all service pipe i.e. inlet, outlet , overflow and scour pipes as fitted in the OHSRMaking arrangement of rent and hiring of DG set for running of tools and plant. |
| 14 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 800 LPM x 35 mtr = 12.50 BHP |
| 15 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 1700 LPM x 40 mtr Head = 25 BHP |
| 16 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER)1050 LPM x 40 Mtr Head |
| 17 | Water Treatment Plant (WTP) - Designing, Testing, Construction and Commissioning of 1.00 MLD capacity water treatment plant including inlet channel alum dozing, flash mixing, clari floculator, filtter box, over head reservoir for back wash, waste water tank, including all civil work pumping machinery and electric cabling, control panel, entire piping network of suitable size, supplying, laying, cutting and jointing of DI pipes from raw water pump to inlet box of WTP, WTP to CWT and Suction well for CW including, DI specials suitable size sluice valves, hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per approved NIT. (make of Sluice valves / NRV: IVC / VAG / Kirloskar) 1.00 MLD Capacity (At 2nd Water works) |
| 18 | Water Treatment Plant (WTP) - Designing, Testing, Construction and Commissioning of 3.50 MLD capacity PLC Scada based water treatment plant including inlet channel alum dozing, flash mixing, clari floculator, filtter box, over head reservoir for back wash, waste water tank, including all civil work pumping machinery and electric cabling, control panel, entire piping network of suitable size, supplying, laying, cutting and jointing of DI pipes from raw water pump to inlet box of WTP, WTP to CWT and Suction well for CW including, DI specials suitable size sluice valves, hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per approved NIT.(make of Sluice valves / NRV: IVC / VAG / Kirloskar) 3.50 MLD Capacity (At 1st Water works) |
| 19 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per ISmarked10500 LPM x 70.00 M (For R/W P/Stn.) |
| 20 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS) 6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos 12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos 13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 10500 LPm x 70 mtr Head = 280 BHP. |
| 21 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping) START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos 2. Controlling MCB - 01nos 3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos 4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos 5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS) 6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos 8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos 9. CAPACITOR BANK AS PER LOAD REQUIREMENT 10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos 11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos 12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos 13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 1400 LPM x 40.00 mtr Head = 20 BHP |
| 22 | Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head 12. 00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirtosker, Crompton Greeve, Lubi) 1100 LPM x 12 mtr Head = 5 BHP |
| 23 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)DOL Starter :- 1.Main MCCB(ABB/LandT/ SCHNEIDER), Controlling MCB - 2nos2.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01nos3. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 01nos4. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS) - 1each5. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos6. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos7. CT RATIO - 100/5 (AE/KAPPA/LandT)8. CAPACITOR BANK AS PER LOAD REQUIREMENT9. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS)10. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB)11. SINGLE PHASE PREVENTER(SECURE/SELEC/TECHNO/ABB)1100 LPM x 12.00 mtr Head = 5 BHP |
| 24 | NS Item -ANNEXE BUILDING: Construction of HT / LT Panel room, PLC room, Blower room and Lab cum Office building, Toilet block including doors, windows, finishing, electric, and sanitary fittings complete in all respect as per drawings approved by SE. The building will be built up with RCC frame structure and brick work as per specifications mentioned in attached additional document |
| 25 | NS Item -MPS (MAIN PUMPING STATION): Design, construction and commissioning of MPS for 3.00 MLD average flow with peak factor 3 including RCC Inlet chamber, screening chamber, wet well sump complete in all respect as per detail and specifications mentioned in attached additional documents along with following provisions:1.1 Providing, fixing and commissioning of 5 non clog sewage submersible pumping sets as per IS marked ie. 1 of 6300, 2 of 2100 and 2 of 1100 LPM having minimum head of 30 mtr along with making all arrangement including sluice valves, Non return valves, specials, flanged individual and common delivery pipes, suitable size LT panel boards and suitable size cable from LT panel to pumps, all safety devices, automatic capacitor bank, complete in all respect as per specification mentioned in attached additional documents.1.1 Conveyance of raw sewage from MPS to inlet chamber of STP through rising main line. ng with cost of DI pipe, sluice valves, specials, material and labor complete in all respect.1.2 Suitable size (as per design) K9 DI pipe at MPS for interconnecting the structures including welding and screwing of flanges, ISI marked D.I. fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respect1.3 Suitable size (as per design and requirement) Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) for screens and partition of tank as per design.1.4 Supply and installation of 1 mechanical and 1 manual coarse screen (SS 304) suitable for 3.00 MLD average flow with peak factor of 3.0 complete in all respect.1.5 All the pumping machinery, panel board, Level sensor etc shall be controlled by PLC and SCADA and shall besynchronized with PLC panels at MPS and STP site through broadband internet facility.1.1 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole along road / path including all accessories complete in all respect.1.6 Raw sewage will be available near boundary wall within the premises of proposed MPS but the conveyance of sewage from this terminal point to the inlet chamber of MPS through DI K9 pipe of suitable diameter as per design is included in the Turnkey contract. The Level of the MPS / STP will be as per bed level of existing incoming sewer at MPS. |
| 26 | NS Item -STP (SEWAGE TREATMENT PLANT) 3.00 MLD: Design, construction, erection, testing and commissioning of 3.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) including Electrical, Mechanical, Piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS including furniture and laboratory equipment as per detail and specifications mentioned in attached additional documents along with following provisions: 1.1 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole alongroad / path including all accessories complete in all respect. 1.2 Supply and fixing of 1 No. 3.65 m wide SS 304 main Gate along with1.25 m. wide wicket gate at STP to the entire satisfaction of Engineer-in-charge. (Total weight not less than 500 kg). 1.3 CC TV CAMERAS: Providing and Installing 6 CCTV Cameras (4 Cameras for STP and 2 Camera at MPS-1) within 96 hours of signing the agreement along with 120 days recording (DVR), 48 inch LED Screen, 16 Channel DVR at STP and MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at MPS and STP shall be synchronized at STP site complete in all respect. PTZ speed dome 360 degree 50X zoom camera, CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode, IR range up to 150 m. CCTV Cameras should be installed and commissioned before starting of the work. Make: Sony / Canon / Panasonic / Samsung 1.4 EWQMS (Effluent water quality monitoring system): Supply, Installation, Testing, Commissioning, Operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 3.00 MLD capacity STP for online (continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents. 1.4.1 Multi-parameter measuring converter, for connecting up to 18 intelligent sensors Scope including 8 analog inputs /outputs (4 inputs and 4 outputs) (0/4-20Ma), wide- range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIS range, for measurement in the outlet / effluent of 3.00 MLD capacity STP with integrated with automatic cleaning complete in all respect. 1.4.2 Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum) complete in all respect. 1.4.3 Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to the intelligent Sensor Net system. Cable length 100 meter (minimum) complete in all respect. 1.4.4 Data transfer to CPCB, HSPCB and PHED servers complete in all respect. 1.4.5 Providing GSM 3G, 4G modem with mobile network connectivity including network including complete in all respect. 1.5 Conveyance of treated effluent from chlorine contact tank to effluent collection tank through suitable size DI K9 pipe along with cost of pipe, sluice valves, specials, material and labor complete in all respect. Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NOplus 2NC and equipped with following switch gears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) a). VCB, 11KV, 630Amp, 50KA. b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciation panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciation panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m)Multi function Meter EM6400NG. n)TCS Relay for Safety. |
| 27 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 2500 LPM x 25 mtr Head = 25 BHP |
| 28 | Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 2500 LPM x 25 Mtr. Head =50 BHP |
| 29 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 5000 LPM x 25 mtr Head = 50 BHP |
| 30 | Supply of submersible motor pumping set non clog for sewerage having head 25 mtr. As per the indicated requirement of discharge in LPM and power capacity in BHP as per IS mark including all accessories like SS pipe, SS chain, SS foundation bolt, complete base frame, monorail, chain guideline, autocupling, duckfoot band etc. complete in all respec. 5000 LPM x 25 Mt. Head = 50 BHP |
| 31 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1 Non clog submercible pumping)START DELTA STARTER :- 1. Main MCCB (ABB/LandT/SCHNEIDER - 01nos2. Controlling MCB - 01nos3.THERMAL OVER LOAD RELAY (ABB/LandT/SCHNEIDER) - 01 nos4. AUXILARY CONTACTOR (ABB/LandT/SCHNEIDER) - 03 nos5. START/STOP PUSH BUTTON (SCHNEIDER/SALZAR/SEIMENS)6. EMERGENCY SWITCH (SCHNEIDER/SALZAR/SEIMENS) - 01 nos7. DIGITAL VAF METER (SECURE/SELEC/TECHNO/ABB) - 01 nos8.CT RATIO - 100/5 (AE/KAPPA/LandT) - 01 nos9. CAPACITOR BANK AS PER LOAD REQUIREMENT10. CHANGE OVER SWITCH AS PER LOAD (SCHNEIDER/SALZAR/SEIMENS) - 01 nos11. SELECTOR SWITCH (SECURE/SELEC/TECHNO/ABB) - 01 nos12. SINGLE PHASE PREVENTER (SECURE/SELEC/TECHNO/ABB) -01 nos13. ELCB BREAKER (ABB/LandT/SCHNEIDER) 1700 LPM x 30 mtr. Head = 20 BHP |
| 32 | Operation and maintenance cum defect liability period for 06 years after successful completion of 3 month trial run period for complete scope of work mentioned in the DNIT Please Enable Macros to View BoQ information |