Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration of metaled , unmetalled surfaces & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge. |
| 2 | Providing and laying cement concrete 1:6:12(1: cement :6 sand :12 graded crushed stone agg. of 40mm. Nominal size) and curing complete excluding the cost of form work in foundation and plinth with in all leads and lifts as per the direction and satisfaction of the Engineer-in-charge. |
| 3 | Random rubble masonry polygonal rubble masonery (uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 racking out of joints in Cement Mortar 1:6 (1cement: 6 sand) with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 4 | Brick work using common burnt clay building bricks (2nd. class) in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement:6 sand) with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 5 | Providing and fixing pressed steel door frames manufacture from commercial mild steel sheet of 1.25mm thick including hinge,jamb,beed and if required angles thrashold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means,adjustable lugs with split and tails to each jamb including steel butt hinges 2.5mm thick with mortar guards,lock stricke plate and shock absarbers as specified and applying a coat of approved steel primer after pretreatment of the surface Profile-B with in all leads and lifts complete in all respect. |
| 6 | Providing and fixing paneled glazed or paneled and glazed shutters for doors, windows and clear story windows including black enameled iron butt hinges with necessary screws 40mm thick second class deodar wood with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 7 | Providing form work with steel plates 3.15mm. thick welded with angle iron in frame 30x30x5mm. So as to give a fair finish including centering shuttering strutting and propping etc, with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu reinforced concrete and plain concrete work in :- |
| 8 | Foundation footing bases of column and the like mass concrete complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 9 | Flat surfaces such as soffits of suspended floor, roofs landing and the like floors etc.upto 200mm in thickness.upto all thickness including all with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 10 | Beams, cantilever, girders and lintels sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 11 | Vertical surfaces such as walls ( any thickness ) partitions and the like including attached pilasters buttersses, plinth and string courses etc, and the like with in all leads and lift as per direction & entire satisfaction of the Engineer-in-charges. |
| 12 | Providing and laying cement concrete 1:2:4(1: cement :2 sand :4 graded crushed stone agg. of 20mm. Nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :- |
| 13 | Foundation footing bases of column and the like mass concrete with in all leads and lifts as per direction of the Engineer-in-charge. |
| 14 | Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 15 | Providing mild steel/tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 16 | Half brick work using common burnt clay building bricks in superstructure above 1st floor level in cement mortar 1:4( 1Cement, 4 Sand ) of 2nd class bricks complete in all respect with in all leads and lifts. |
| 17 | Pointing on brick work with cement mortar 1:3 ( 1 cement, 3 sand ) with in all leads and lifts complete in all respect. |
| 18 | Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 ( 1cement,3 sand ) over a 12 mm layer of C.M 1:3 ( 1 cement, 3 sand ) and finished neat with in all leads and lifts complete in all respect. |
| 19 | 6mm thick cement plaster to ceiling in cement mortor 1:3(One cement: three sand) with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 20 | 15mm thick cement plaster in single coat on rough side of bricks/ stone masonary for interior plastering upto floor two level including arrises, internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in C.M 1:6 (One cement: six sand) with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 21 | 20mm thick cement plaster in single coat on rough side of bricks/ stone masonary for interior plastering upto floor two level including arrises, internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in C.M 1:6 (One cement: six sand) with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 22 | Providing and fixing MS grills of required pattern in wooden frames of window etc with M.S flat square or round bars with round headed bolts and nuts or by screw with in all leads and lifts complete in all respect. |
| 23 | Providing and fixing wire gauge shutters using galvanised MS wire gauge of IS gauge designation 85 G.with wire of dia 0.56 mm for doors windows and cleerestorey windows including bright finished black anamelled iron hinges with necessary screws 40mm thick 2nd class deodar wood complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 24 | Stone filling under floor with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 25 | Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 26 | Constructing coursed rubble hammer dressed \\"U\\" shape open surface drain with side wall 15 X 22 cm in cementy mortar 1:6 ( 1 cement, 6 sand ) and inside plastering with cement mortar 1:3 ( 1 cement, 3 sand ) i/c earth work and laying 10 cms cement concrete in 1:5;10 ( 1 cement,5 sand,10 graded stone aggregate 40 mm nominal size ) and 7.5 cms cement concrete 1:2:4 ( 1 cement,2 sand,4 graded stone aggregate 20 mm nominal size ) and finished with a floating coat of neat cement complete as per standard design with in all leads and lifts complete in all respect. |
| 27 | Providdng 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts,nuts and wooden plug and embeded in cement concrete block 30x10x15cm in 1:3:6(one cement:three sand:six graded stone aggregate 40mm nominal size) complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 28 | Providing and fixing M.S. fan clamp(Type-I of 16mm dia M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all respect with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 29 | White washing with lime on un-decorated wall surface (two coats) to give an even shade including thoroughly brooming the surface to remove all dust, dirt mortor dirt and other foreign matter with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 30 | Distempering with dry distemper of approved brand and manufacturer ( Two Coats ) and of required shade on un-decorated wall surfaces to give an even shade over and including priming coat of whiting after throughly brushing the surface free from mortar and other foreign matters with in all leads and lifts complete in all respect. |
| 31 | Finishing wall with water proofing cement paint (smosum) of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials within all leads and lifts as per direction of the Engineer-in-charge. |
| 32 | Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts, nuts, screw etc. complete in all respect with in all leads and lifts as per direction and satisfaction of the Engineer-in-charge. 250x16mm. |
| 33 | Providing and fixing aluminium tower bolt (berrel type) anodized transparent or dyed to required shade colour with screw etc. complete in all respect with in all leads and lifts as per direction and satisfaction of the Engineer-in-charge. 200x10mm |
| 34 | Providing and fixing aluminium handle anodized transparent or dyed to required shade colour with necessary screw etc. complete in all respect with in all leads and lifts as per direction and satisfaction of the Engineer-in-charge. 100 mm. |
| 35 | Painting two coats excluding priming coat on new steel and other metal surfaces with ready mixed paint and brushing to give an even shade including cleaning of all dirt, dust and other foreign matter with in all leads and lifts complete in all respect. |
| 36 | Terrazzo tile flooring with precast terrazzo tiles 20 mm thick with marble chips of specified size laid in floors,treads of steps and landing on a bed of 25 mm average thickness of cemenrt mortar 1 :6 ( 1 cement,6 sand ) jointed with neat cement slurry mixed with pigment to match the shade of tile where ever required including rubbing and polishing complete with tiles of following shades medium with in all leads and lifts complete in all respect. |
| 37 | Providing and laying cement concrete 1:3:6(1: cement :3 sand :6 graded crushed stone agg. of 40mm. Nominal size) and curing complete excluding the cost of form work in foundation and plinth with in all leads and lifts as per direction of the Engineer-in-charge. |
| 38 | Providing and laying cement concrete 1:1.5:3(1: cement :1.5 sand :3 graded crushed stone agg. of 20mm. Nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :- |
| 39 | Foundation footing bases of column and the like mass concrete with in all leads and lifts as per direction of the Engineer-in-charge. |
| 40 | Wall ( any thickness but not less than 0.10 mtr. Thickness) including attached pilasters buttersses, plinth and string courses etc, from top of foundation upto floor two level complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 41 | Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level with in all leads & lifts as per direction & entire satisfaction of the Engineer - in- charge. |
| 42 | Arches upto floor two level complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 43 | Providing form work of ordinary timber plankings so as to give a rough finish i/c centring, shuttering,strutting & propping etc. ht.of propping & centring below supporting floor to ceiling not exceeding 4 mts. & removal of the same for insitu-reinforced concrete & plain concrete work in :- |
| 44 | Arches beyond 6.00 mtr. span complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 45 | Providing in RCC work smooth finishing of the exposed surface with cement motor 1:3 ( 1 cement : 3 sand) complete in all respect complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 46 | Steel work welded in built up section trusses and framed work i/c cutting hoisting fixing in position and applying a priming coat of red lead paint in gratings framed guards bars, ladders railing, brackets and similar work complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 47 | Providing & laying in trenches GMS/MS Tubes Screwed and sockected pipe (L/M class) tube fitting (Earth work in trenches to be measured & paid for separatly) complete in all respect within all leads and lifts. i) 80 mm dia & 100 mm dia |
| 48 | Providing, supplying & fixing of Cast iron sluice valves (with hand wheel) confirming to BIS 780-1986 (Latest with upto date ammendmends) class PN 1.00 of 10.20 Kg/cm2 seat pressure of Leader/Kirlosker make as per the emtire satisfaction of Engineer-in-charge within all leads & lifts |
| 49 | 80mm Dia. |
| 50 | 100mm Dia. |
| 51 | Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.(Medium duty). The weight of cover & frame should not be less than 100 kg complete in all respect with in all leads and lift as per direction & satisfaction of the Engineer-in-charges. |
| 52 | Providing ,Laying, jointing & testing of GI pipe as per IS 1239-2012 with upto date amendments (plain ended pipe) with circumfrential butt welded joints by electrical arc welding (94% welding and 6%flanged joint ) with minimum two layers capable to withstand required test pressure (minimum welding thickness shall be equal to pipe wall thickness) including manufacturing and fabrication of reducers/ tapers, all short pieces, bends of required degrees as per site requirement made from parent tubes. The laying of pipe shall also include intermediate flanged joints spaced at an interval of 16 pipe lengths or where ever required as per direction of the Engineer-in-charge duly welded in three layers (two for outer & one on inner side) and all other operations such as cutting, welding, jointing, fabrication of bends, tees etc , lowering and laying in excavated trench to ensure required level including flushing, cleaning and hydraulic testing complete in all respects & to the entire satisfaction of the Engineer in charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately).The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes and all the specials ( If damaged during laying & jointing operation of pipe) made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing, D.P. test of butt welded joints complete in all respect and to the satisfaction & direction of Engineer in charge with in all leads and lifts. |
| 53 | Booster stage (P/ Well to Collection Tank) for Rising Main 80 mm dia GI pipe Plain ended (Medium class ) at RD. 0.00 mtr. to 590.00 mtr. = 590.00 Mtr. Wall thickness 4.00mm |
| 54 | Stage 1st. for Rising Main 80 mm dia GI pipe Plain ended (Medium class ) at RD. 0.00 mtr. to 990.00 mtr. = 990.00 Mtr.Wall thickness 4.00mm |
| 55 | Booster stage (P/ Well to Collection Tank) for Rising Main 100mm dia GI pipe Plain ended (Medium class ) at RD. 0.00 mtr. to 590.00 mtr. = 590.00 Mtr. Wall thickness 4.50mm |
| 56 | Stage 1st. for Rising Main 100mm dia GI pipe Plain ended (Medium class ) at RD. 0.00 mtr. to 990.00 mtr. = 990.00 Mtr. Wall thickness 4.50mm |
| 57 | Providing and welding M.S. flanges at suitable points to be provided 6%, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) with plain end GI pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of GI pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts. |
| 58 | Booster stage (P/ Well to Collection Tank) for Rising Main 80 mm dia Flange Table-5 at RD. 0.00 mtr. to 590.00 mtr. = 590.00 Mtr. |
| 59 | Stage 1st. for Rising Main 80 mm dia Flange Table-28 at RD. 0.00 mtr. to 990.00 mtr. = 990.00 Mtr. |
| 60 | Booster stage (P/ Well to Collection Tank) for Rising Main 100mm dia Flange Table-5 at RD. 0.00 mtr. to 590.00 mtr. = 590.00 Mtr. |
| 61 | Stage 1st. for Rising Main 100mm dia Flange Table-28 at RD. 0.00 mtr. to 990.00 mtr. = 990.00 Mtr. |
| 62 | LWSS Sakri |
| 63 | Supply of submersible pumping set of KSB//Kirloskar /Johnston/Crompton/BS/ SABAR/ Oswal make conforming to latest relevant BIS Code 8034:1976. The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900/1450rpm of reputed make conforming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips and depth gauge etc. |
| 64 | Location of site :- P/Well at village Bassa on Baner Khad. |
| 65 | The Altitude of place in which the motor is intended to work :- Altitude of phase is 454 mtr. Above mean sea level. |
| 66 | Type of current :- A.C. Three phase supply with frequency of 50 cycles per second. |
| 67 | Rated Voltage :- 415 (+/-) 10% Treated. |
| 68 | Type of water (Raw/ Treated) Clear Water |
| 69 | Water free from sand or not : - Free from sand (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 70 | Humidity :- Humid during rainy season. |
| 71 | Nature of atmosphere :- Normal |
| 72 | Water corrosive or not :- Not corrosive |
| 73 | Turbidity :- Less than 50.00 ppm |
| 74 | Inside dia of well 6.00 mtr. |
| 75 | Depth of P/well 12.00 mtr. |
| 76 | No. of pump required 2 Nos (One stand by) |
| 77 | Discharge required from each Pump 24.95 cumper hour (For each Pump) |
| 78 | Static Head in mtr 31.00 mtr. |
| 79 | Total head in mtr 39.12 mtr. |
| 80 | Length of R/Main 590.00 mtr. |
| 81 | Dia of R/Main 100 mm dia G.M. Pipe Medium class |
| 82 | No of working hours P/day 8.00 Hours |
| 83 | Limits of pump operction ( - ) 15 % ( + ) 10 % of total head |
| 84 | H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10 |
| 85 | R.M.P. of Pump (2900/1450) 2900 RPM |
| 86 | MNPSH available 450 M |
| 87 | Test Run 16 hours Continueously for 7 days |
| 88 | Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 89 | Supply of suitable oil immersed star delta starter of standard make such as MEI / Kildurn / L & T / Jyoti / siemens conforming to Bis - 8544-1979 latest with upto date amendments for squirrel cage /slipring Motor (make to be specified by the tenderers) mounted on panel board with Megnatic type over load release and deshpot, time, lag under voltage release with initial oil fillings. Note:- Star Delta starter upto 37.5 K.W. Ats. between 37.5 K.W. to 50 K.W. and starter rotor starter with slipering motor beyound 50K.W. |
| 90 | Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 65x65x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. Note:- The drawing of panel board shall be subject to approval of Engineer in charge. |
| 91 | Ammeter of required capacity AC supply,100 mm square dial Auto electric/IMP/Havelss make of suitable range for above motor with selector switches conforming to BIS: 1248-1983 latest with up to date ammendments. |
| 92 | Voltmeter of required capacity AC supply,100 mm Auto electric/IMP/Havells make of suitable range for above Pumping Set with selector switches conforming to BIS: 8044-1978 with up to date ammendments. |
| 93 | ICTP switches ( complete set) of required capacity with HRC fuses L&T/Havell's make and having capacity 30% extra of the operational rating of motor as per BIS: 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. |
| 94 | Busbar chamber having 3 copper bars of suitable rating for full length of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS: 8084-1976 and BIS;11353-1985 read with BIS;5578-1985 all latest with upto date ammendments. |
| 95 | MCB of required capacity of KilburnL&T/MEI/ standared/GEC make on in comming feeder for motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date ammendments with neutral linked under voltage release. |
| 96 | Three phase indicating lamps( complete set) with toggle switches for individual phase conforming to BIS: 3452 ( part I & II) latest with up to date ammendments. |
| 97 | Earth leakage circuit breaker (ELCB) of required capacity with20x3 Copper strip of Indtech/Datar/ Havell's make as per BIS: 2516-1977 with upto date ammendments and of suitaible range 20x3mm coper strips, with which should have control box, operating handel and trip/reset bush button, on/ off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnetic thermal release with metallic tape CTs.It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/off breaker load side. |
| 98 | Supply of Kirloskar/Leader make C.I. double flanged actuated Sluice valve (to be provided on delivery side) cnforming to BIS 780-1984 ( Class PN-1.0) having size one step higher than the delivery size of pump and capable of with standing nominal seat test pressure of _10.20_ kg/cm². ( The size of valve to be specified by the tenderer) |
| 99 | Supply of Kirloskar/Leader/ make C.I. double flanged actuated swing check type refluxe valve(to be provided on delivery side) conforming to BIS 5312 ( class PN 1.0) having bye pass arrangement of size one step higher than the delivery size of pump ( size of valve to be specified by the tenderer)and shall be suitable for withstanding nominal seat pressure of 10.20 kg/cm². ( The size of valve to be specified by the tenderer) |
| 100 | Providing and laying of suitable size copper PVC insulated armoured power 3½ core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of Siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. On Supply side ........ mm² ( The size of cable shall be specifed by the tenderer ) |
| 101 | Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) of Siemen / Gloster /ICC finollex make suitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. On Motor side --- mm²( The size of cable shall be specifed by the tenderer). |
| 102 | Providing & laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & copper strips of 20x3mm suitable size conforming to BIS:3043-1987 (latest edition) for above motors & other electrical equipments. (NOTE:-The strip size shall be 20x3 upto 18.5 KW, 25x3 for 18.5 to 37 KW, 25x5 for 37 to 55 KW & 32x5 beyond 55 KW) |
| 103 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Havells/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable of Siemens/Gloster/ICC make from busbar chamber chamber to capacitor & also including ICTP switches Kilburn/L&T/Standard/Siemen's/Havell's of conforming to 4064-1978 or latest with HRC fuses with two years warrantee . (KVAR to be specified by the tenderer) |
| 104 | Supply of 100mm dia circular dial pressure gaugeof suitable range of Fiebeg make with all accessories such as stop cock,copper tubing etc. conforming to BIS:3624-1987 latest with up to date ammendments. |
| 105 | Providing & laying G.I. pipes (M) Class as per BIS 1239-2012 ( latest)/GMS pipe 4.50mm thick of suitable size for Column pipe and making connection with R/Main considering site requirements & depth required / available in the P/well.The column pipe shall be be flanged at every 3 metre length as per the requirement of offered pump (to be given by the tenederer) and connecting pipe shall be equal to dia of R/main including tapers, flanges, bends, rubber gaskets,3mm thick nuts & bolts and specials up to 5 mtrs. away from the outer wall of pump house as per layout drawing approved by Engineer-in-Charge. The pipes material shall conform to relevant BIS codes and capable of withstanding field test pressure equal to 1.5 times the operating pressure The complete arrangement shall comprise of:- |
| 106 | Column pipe for P/ well - …...mm dia ( To be specified by the tenderer) |
| 107 | Connecting Delivery pipe with R/main …...mm dia ( To be specified by the tenderer) |
| 108 | Errection of all equipments as per required items i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge |
| 109 | Providing horizontal spindle casing/end and suction (back pull out arrangement) single/double/multistage stage centrifugal pump or combination of pumps in series/parallel of recommended make such as KSB / Kirloskar / Mather and Platt /Crompton /Becon Weir / BE / Jyoti as per BIS 1520-1980 with up to date amendments read with 9137-1978 or latest addition suitable to lift clear water under mentioned characteristics with bronze impellers / priming funnels casing rings and shaft sleeves of bronze , shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common mild Steel base plate (base plate to be from the manufacturer of the pumping unit only) to squirrel cage /slipring screen protected drip proof induction motor of standard make such as Kirloskar / crpmpton / BHEL/ NGEF / GEC / Siemens / Jyoti /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 suitable for operation on 400(+/-) 10% volts, 50 cycles/ second ,3 phase AC electric Supply .. It should include cost of bearing nuts bolts and pointing etc. and should meet the following requirements :- The pumping machinery shall be installed on a proper designed base plate. The foundation of the machinery should be proper designed and anchored properly . |
| 110 | Location of site :- P/Well at village Bassa on Baner Khad. |
| 111 | The Altitude of place in which the motor is intended to work :- Altitude of phase is 454 mtr. Above mean sea level. |
| 112 | Type of current :- A.C. Three phase supply with frequency of 50 cycles per second. |
| 113 | Rated Voltage :- 415 (+/-) 10% Treated. |
| 114 | Type of water (Raw/ Treated) Clear Water |
| 115 | Water free from sand or not : - Free from sand (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 116 | Humidity :- Humid during rainy season. |
| 117 | Nature of atmosphere :- Normal |
| 118 | Water corrosive or not :- Not corrosive |
| 119 | Turbidity :- Less than 50.00 ppm |
| 120 | No. of pump required 2 Nos (One stand by) |
| 121 | Discharge required from each Pump 5.90 LPS (For each Pump) |
| 122 | Total Dynamic Head in mtr 313.20 mtr. |
| 123 | L.W.L. in P/ Well 444.10 mtr |
| 124 | Pump Shaft Leval 443.10 mtr. |
| 125 | Discharge level of highest point 460.00 mtr |
| 126 | Suction lift + (ve) |
| 127 | Residual Head 3.00 Mtr. |
| 128 | Static head in mtr 236.90 mtr. |
| 129 | Length of R/Main 4210.00 / 990.00 mtr. |
| 130 | Dia of R/Main 100 mm dia G.M. Pipe Medium class |
| 131 | No of working hours P/day 16.00 Hours |
| 132 | Limits of pump operction ( - ) 15 % ( + ) 10 % of total head |
| 133 | H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10 |
| 134 | R.M.P. of Pump (2900/1450) 2900 RPM |
| 135 | MNPSH available 460 M |
| 136 | Test Run 16 hours Continueously for 7 days |
| 137 | Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 138 | Supply of suitable oil immersed star delta starter of standard make such as MEI / Kildurn / L & T / Jyoti / siemens conforming to Bis - 8544-1979 latest with upto date amendments for squirrel cage /slipring Motor (make to be specified by the tenderers) mounted on panel board with Megnatic type over load release and deshpot, time, lag under voltage release with initial oil fillings. Note:- Star Delta starter upto 37.5 K.W. Ats. between 37.5 K.W. to 50 K.W. and starter rotor starter with slipering motor beyound 50K.W. |
| 139 | Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 65x65x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. Note:- The drawing of panel board shall be subject to approval of Engineer in charge. |
| 140 | Ammeter of required capacity AC supply,100 mm square dial Auto electric/IMP/Havelss make of suitable range for above motor with selector switches conforming to BIS: 1248-1983 latest with up to date ammendments. |
| 141 | Voltmeter of required capacity AC supply,100 mm Auto electric/IMP/Havells make of suitable range for above Pumping Set with selector switches conforming to BIS: 8044-1978 with up to date ammendments. |
| 142 | ICTP switches ( complete set) of required capacity with HRC fuses L&T/Havell's make and having capacity 30% extra of the operational rating of motor as per BIS: 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. |
| 143 | Busbar chamber having 3 copper bars of suitable rating for full length of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS: 8084-1976 and BIS;11353-1985 read with BIS;5578-1985 all latest with upto date ammendments. |
| 144 | MCCB of required capacity of KilburnL&T/MEI/ standared/GEC make on in comming feeder for motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date ammendments with neutral linked under voltage release. |
| 145 | Three phase indicating lamps (complete set) with toggle switches for individual phase conforming to BIS: 3452 ( part I & II) latest with up to date ammendments. |
| 146 | ELR of required capacity with.20x3 Copper strip of Indtech/Datar/ Havell's make as per BIS: 2516-1977 with upto date ammendments and of suitaible range 20x3mm coper strips, with which should have control box, operating handel and trip/reset bush button, on/ off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnetic thermal release with metallic tape CTs.It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/off breaker load side. |
| 147 | Hour run meter of approved CE/Kaycee make of four digit capacity conforming to BIS: 722 (latest edition) |
| 148 | Change over Switch of reputed make & suitable capacity conforming to relevant BIS code |
| 149 | Single phase preventor of reputed make & suitable capacity conforming to relevant BIS code |
| 150 | Three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing low voltage, hight voltage & overloading & phase voltage difference as per BIS: 3842 (lates addition) of suitable capacity. |
| 151 | Providing & fixing Cast Steel double flanged actauted sulice valve of Kirloskar /KSB/ Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class ASA-150 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 21.00 kg/Cm2. (conforming to BS 1414/API-600) ( The size of valve shall be specified by the Tenderer ) |
| 152 | Providing & fixing of Cast Steel double flanged swing check type actuated Reflex valve of Kirloskar /KSB/ Kilburn / BHEL/ Leader make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class ASA-150 ) and shall be suitable for with standing nominal seat pressure of 21.00 Kg /Cm^2 ) ( as per BS - conforming to BS:1868/ API-600 ( The size of valve shall be specifed by the tenderer ) |
| 153 | Providing & fixing of Cast Steel double flanged swing check type actuated Reflex valve of Kirloskar / Kilburn /KSB / BHEL/ Leader make having by pass arrangement and size equal to dia of R/Main that is 100 mm dia and class - ASA-150 ) and shall be suitable for with standing nominal seat pressure of 21.00 Kg /Cm^2 ) conforming to IS :BS: 1868/API-600. |
| 154 | Providing & fixing Cast Iron double flanged sulice valve of Kirloskar /KSB/ Kilburn / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.0 having one size higher to suction side size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer ) |
| 155 | Providing and laying of suitable size copper PVC insulated armoured power 3½ core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. On Supply side ........ mm² ( The size of cable shall be specifed by the tenderer ) |
| 156 | Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) of Siemen / Gloster /ICC finollex makesuitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. On Motor side --- mm²( The size of cable shall be specifed by the tenderer). |
| 157 | Providing & laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & copper strips of 20x3mm suitable size conforming to BIS:3043-1987 (latest edition) for above motors & other electrical equipments. |
| 158 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Havells/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable of Siemens/Gloster/ICC make from busbar chamber chamber to capacitor & also including ICTP switches Kilburn/L&T/Standard/Siemen's/Havell's of conforming to 4064-1978 or latest with HRC fuses with two years warrantee. ( KVAR of capacitor to be specified by the Tenderer) |
| 159 | Supply of 100mm dia circular dial pressure gaugeof suitable range of Fiebeg make with all accessories such as stop cock,copper tubing etc. conforming to BIS:3624-1987 latest with up to date ammendments. |
| 160 | Providing & laying G.I. pipes (M) Class as per BIS 1239-2012 ( latest)/GMS pipe 4.50mm thick of suitable size for Column pipe and making connection with R/Main considering site requirements & depth required / available in the P/well.The column pipe shall be be flanged at every 3 metre length as per the requirement of offered pump (to be given by the tenederer) and connecting pipe shall be equal to dia of R/main including tapers, flanges, bends, rubber gaskets,3mm thick nuts & bolts and specials up to 5 mtrs. away from the outer wall of pump house as per layout drawing approved by Engineer-in-Charge. The pipes material shall conform to relevant BIS codes and capable of withstanding field test pressure equal to 1.5 times the operating pressure The complete arrangement shall comprise of:- |
| 161 | Suction pipe ( To be mentioned by tenderer) |
| 162 | Delivery pipe ( To be mentioned by tenderer) |
| 163 | Common header 100 mm dia GMS pipe |
| 164 | Errection of all equipments as per required items i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge |
| 165 | LWSS Jalakh |
| 166 | Supply of submersible pumping set of KSB//Kirloskar /Johnston/Crompton/BS/ SABAR/ Oswal make conforming to latest relevant BIS Code 8034:1976. The pump should be fitted with bronze impeller or suitable alloys suitable for handling Clear water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP & 2900/1450rpm of reputed make conforming to BIS 9283-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips and depth gauge etc. |
| 167 | Location of site :- P/Well at village Bassa on Baner Khad. |
| 168 | The Altitude of place in which the motor is intended to work :- Altitude of phase is 454 mtr. Above mean sea level. |
| 169 | Type of current :- A.C. Three phase supply with frequency of 50 cycles per second. |
| 170 | Rated Voltage :- 415 (+/-) 10% Treated. |
| 171 | Type of water (Raw/ Treated) Clear Water |
| 172 | Water free from sand or not : - Free from sand (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 173 | Humidity :- Humid during rainy season. |
| 174 | Nature of atmosphere :- Normal |
| 175 | Water corrosive or not :- Not corrosive |
| 176 | Turbidity :- Less than 50.00 ppm |
| 177 | Inside dia of well 6.00 mtr. |
| 178 | Depth of P/well 12.00 mtr. |
| 179 | No. of pump required 2 Nos (One stand by) |
| 180 | Discharge required from each Pump 4.27 LPS (For each Pump) |
| 181 | Static Head in mtr 31.00 mtr. |
| 182 | Total head in mtr 49.13 mtr. |
| 183 | Length of R/Main 590.00 mtr. |
| 184 | Dia of R/Main 80 mm dia G.M. Pipe Medium class |
| 185 | No of working hours P/day 8.00 Hours |
| 186 | Limits of pump operction ( - ) 15 % ( + ) 10 % of total head |
| 187 | H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10 |
| 188 | R.M.P. of Pump (2900/1450) 2900 RPM |
| 189 | MNPSH available 450 M |
| 190 | Test Run 16 hours Continueously for 7 days |
| 191 | Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 192 | Supply of suitable oil immersed star delta starter of standard make such as MEI / Kildurn / L & T / Jyoti / siemens conforming to Bis - 8544-1979 latest with upto date amendments for squirrel cage /slipring Motor (make to be specified by the tenderers) mounted on panel board with Megnatic type over load release and deshpot, time, lag under voltage release with initial oil fillings. Note:- Star Delta starter upto 37.5 K.W. Ats. between 37.5 K.W. to 50 K.W. and starter rotor starter with slipering motor beyound 50K.W. |
| 193 | Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 65x65x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. Note:- The drawing of panel board shall be subject to approval of Engineer in charge. |
| 194 | Ammeter of required capacity AC supply,100 mm square dial Auto electric/IMP/Havelss make of suitable range for above motor with selector switches conforming to BIS: 1248-1983 latest with up to date ammendments. |
| 195 | Voltmeter of required capacity AC supply,100 mm Auto electric/IMP/Havells make of suitable range for above Pumping Set with selector switches conforming to BIS: 8044-1978 with up to date ammendments. |
| 196 | ICTP switches ( complete set) of required capacity with HRC fuses L&T/Havell's make and having capacity 30% extra of the operational rating of motor as per BIS: 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. |
| 197 | Busbar chamber having 3 copper bars of suitable rating for full length of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS: 8084-1976 and BIS;11353-1985 read with BIS;5578-1985 all latest with upto date ammendments. |
| 198 | MCB of required capacity of KilburnL&T/MEI/ standared/GEC make on in comming feeder for motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date ammendments with neutral linked under voltage release. |
| 199 | Three phase indicating lamps( complete set) with toggle switches for individual phase conforming to BIS: 3452 ( part I & II) latest with up to date ammendments. |
| 200 | Earth leakage circuit breaker (ELCB) of required capacity with20x3 Copper strip of Indtech/Datar/ Havell's make as per BIS: 2516-1977 with upto date ammendments and of suitaible range 20x3mm coper strips, with which should have control box, operating handel and trip/reset bush button, on/ off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnetic thermal release with metallic tape CTs.It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/off breaker load side. |
| 201 | Supply of Kirloskar/Leader make C.I. double flanged actuated Sluice valve (to be provided on delivery side) cnforming to BIS 780-1984 ( Class PN-1.0) having size one step higher than the delivery size of pump and capable of with standing nominal seat test pressure of _10.20_ kg/cm². ( The size of valve to be specified by the tenderer) |
| 202 | Supply of Kirloskar/Leader/ make C.I. double flanged actuated swing check type refluxe valve(to be provided on delivery side) conforming to BIS 5312 ( class PN 1.0) having bye pass arrangement of size one step higher than the delivery size of pump ( size of valve to be specified by the tenderer)and shall be suitable for withstanding nominal seat pressure of 10.20 kg/cm². ( The size of valve to be specified by the tenderer) |
| 203 | Providing and laying of suitable size copper PVC insulated armoured power 3½ core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of Siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. On Supply side ........ mm² ( The size of cable shall be specifed by the tenderer ) |
| 204 | Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) of Siemen / Gloster /ICC finollex make suitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. On Motor side --- mm²( The size of cable shall be specifed by the tenderer). |
| 205 | Providing & laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & copper strips of 20x3mm suitable size conforming to BIS:3043-1987 (latest edition) for above motors & other electrical equipments. (NOTE:-The strip size shall be 20x3 upto 18.5 KW, 25x3 for 18.5 to 37 KW, 25x5 for 37 to 55 KW & 32x5 beyond 55 KW) |
| 206 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Havells/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable of Siemens/Gloster/ICC make from busbar chamber chamber to capacitor & also including ICTP switches Kilburn/L&T/Standard/Siemen's/Havell's of conforming to 4064-1978 or latest with HRC fuses with two years warrantee . (KVAR to be specified by the tenderer) |
| 207 | Supply of 100mm dia circular dial pressure gaugeof suitable range of Fiebeg make with all accessories such as stop cock,copper tubing etc. conforming to BIS:3624-1987 latest with up to date ammendments. |
| 208 | Providing & laying G.I. pipes (M) Class as per BIS 1239-2012 ( latest)/GMS pipe 4.00mm thick of suitable size for Column pipe and making connection with R/Main considering site requirements & depth required / available in the P/well.The column pipe shall be be flanged at every 3 metre length as per the requirement of offered pump (to be given by the tenederer) and connecting pipe shall be equal to dia of R/main including tapers, flanges, bends, rubber gaskets,3mm thick nuts & bolts and specials up to 5 mtrs. away from the outer wall of pump house as per layout drawing approved by Engineer-in-Charge. The pipes material shall conform to relevant BIS codes and capable of withstanding field test pressure equal to 1.5 times the operating pressure The complete arrangement shall comprise of:- |
| 209 | Column pipe for P/ well - …...mm dia ( To be specified by the tenderer) |
| 210 | Connecting Delivery pipe with R/main …...mm dia ( To be specified by the tenderer) |
| 211 | Errection of all equipments as per required items i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge |
| 212 | Providing horizontal spindle casing/end and suction (back pull out arrangement) single/double/multistage stage centrifugal pump or combination of pumps in series/parallel of recommended make such as KSB / Kirloskar / Mather and Platt /Crompton /Becon Weir / BE / Jyoti as per BIS 1520-1980 with up to date amendments read with 9137-1978 or latest addition suitable to lift clear water under mentioned characteristics with bronze impellers / priming funnels casing rings and shaft sleeves of bronze , shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common mild Steel base plate (base plate to be from the manufacturer of the pumping unit only) to squirrel cage /slipring screen protected drip proof induction motor of standard make such as Kirloskar / crpmpton / BHEL/ NGEF / GEC / Siemens / Jyoti /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 suitable for operation on 400(+/-) 10% volts, 50 cycles/ second ,3 phase AC electric Supply .. It should include cost of bearing nuts bolts and pointing etc. and should meet the following requirements :- The pumping machinery shall be installed on a proper designed base plate. The foundation of the machinery should be proper designed and anchored properly . |
| 213 | Location of site :- P/Well at village Bassa on Baner Khad. |
| 214 | The Altitude of place in which the motor is intended to work :- Altitude of phase is 454 mtr. Above mean sea level. |
| 215 | Type of current :- A.C. Three phase supply with frequency of 50 cycles per second. |
| 216 | Rated Voltage :- 415 (+/-) 10% Treated. |
| 217 | Type of water (Raw/ Treated) Clear Water |
| 218 | Water free from sand or not : - Free from sand (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 219 | Humidity :- Humid during rainy season. |
| 220 | Nature of atmosphere :- Normal |
| 221 | Water corrosive or not :- Not corrosive |
| 222 | Turbidity :- Less than 50.00 ppm |
| 223 | No. of pump required 1 No |
| 224 | Discharge required from each Pump 3.64 LPS (For each Pump) |
| 225 | Total Dynamic Head in mtr 228.71 mtr. |
| 226 | L.W.L. in P/ Well 446.00 mtr |
| 227 | Pump Shaft Leval 444.00 mtr. |
| 228 | Discharge level of highest point 603.20 mtr |
| 229 | Suction lift + (ve) |
| 230 | Residual Head 3.00 Mtr. |
| 231 | Static head in mtr 159.20 mtr. |
| 232 | Length of R/Main 3210.00 / 990.00 mtr. |
| 233 | Dia of R/Main 80 mm dia G.M. Pipe Medium class |
| 234 | No of working hours P/day 16.00 Hours |
| 235 | Limits of pump operction ( - ) 15 % ( + ) 10 % of total head |
| 236 | H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10 |
| 237 | R.M.P. of Pump (2900/1450) 2900 RPM |
| 238 | MNPSH available 460 M |
| 239 | Test Run 16 hours Continueously for 7 days |
| 240 | Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 10 NTP (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______ |
| 241 | Supply of suitable oil immersed star delta starter of standard make such as MEI / Kildurn / L & T / Jyoti / siemens conforming to Bis - 8544-1979 latest with upto date amendments for squirrel cage /slipring Motor (make to be specified by the tenderers) mounted on panel board with Megnatic type over load release and deshpot, time, lag under voltage release with initial oil fillings. Note:- Star Delta starter upto 37.5 K.W. Ats. between 37.5 K.W. to 50 K.W. and starter rotor starter with slipering motor beyound 50K.W. |
| 242 | Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 65x65x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. Note:- The drawing of panel board shall be subject to approval of Engineer in charge. |
| 243 | Ammeter of required capacity AC supply,100 mm square dial Auto electric/IMP/Havelss make of suitable range for above motor with selector switches conforming to BIS: 1248-1983 latest with up to date ammendments. |
| 244 | Voltmeter of required capacity AC supply,100 mm Auto electric/IMP/Havells make of suitable range for above Pumping Set with selector switches conforming to BIS: 8044-1978 with up to date ammendments. |
| 245 | ICTP switches ( complete set) of required capacity with HRC fuses L&T/Havell's make and having capacity 30% extra of the operational rating of motor as per BIS: 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. |
| 246 | Busbar chamber having 3 copper bars of suitable rating for full length of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS: 8084-1976 and BIS;11353-1985 read with BIS;5578-1985 all latest with upto date ammendments. |
| 247 | MCB of required capacity of KilburnL&T/MEI/ standared/GEC make on in comming feeder for motors offered by the tenderer conforming to BIS: 2516-1985 latest with upto date ammendments with neutral linked under voltage release. |
| 248 | Three phase indicating lamps (complete set) with toggle switches for individual phase conforming to BIS: 3452 ( part I & II) latest with up to date ammendments. |
| 249 | Earth leakage circuit breaker (ELCB) of required capacity with.20x3 Copper strip of Indtech/Datar/ Havell's make as per BIS: 2516-1977 with upto date ammendments and of suitaible range 20x3mm coper strips, with which should have control box, operating handel and trip/reset bush button, on/ off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnetic thermal release with metallic tape CTs.It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/off breaker load side. |
| 250 | Hour run meter of approved CE/Kaycee make of four digit capacity conforming to BIS: 722 (latest edition) |
| 251 | Change over Switch of reputed make & suitable capacity conforming to relevant BIS code |
| 252 | Single phase preventor of reputed make & suitable capacity conforming to relevant BIS code |
| 253 | Three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing low voltage, hight voltage & overloading & phase voltage difference as per BIS: 3842 (lates addition) of suitable capacity. |
| 254 | Providing & fixing Cast Steel double flanged actauted sulice valve of Kirloskar /KSB/ Kilburn /IVC/ Fouress / Gled / BHEL/ Leader make of size suitable as per offered pump and class ASA-150 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 21.00 kg/Cm2. (conforming to BS 1414/API-600) ( The size of valve shall be specified by the Tenderer ) |
| 255 | Providing & fixing of Cast Steel double flanged swing check type actuated Reflex valve of Kirloskar /KSB/ Kilburn / BHEL/ Leader make having by pass arrangement suitable size higher to delivery size of pump( Size ____ mm & class ASA-150 ) and shall be suitable for with standing nominal seat pressure of 21.00 Kg /Cm^2 ) ( as per BS - conforming to BS:1868/ API-600 ( The size of valve shall be specifed by the tenderer ) |
| 256 | Providing & fixing of Cast Steel double flanged swing check type actuated Reflex valve of Kirloskar / Kilburn /KSB / BHEL/ Leader make having by pass arrangement and size equal to dia of R/Main that is 80 mm dia and class - ASA-150 ) and shall be suitable for with standing nominal seat pressure of 21.00 Kg /Cm^2 ) conforming to IS :BS: 1868/API-600. |
| 257 | Providing & fixing Cast Iron double flanged sulice valve of Kirloskar /KSB/ Kilburn / BHEL/ Leader make of size suitable as per offered pump and class PN- 1.0 having one size higher to suction side size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984) ( The size of valve shall be specified by the Tenderer ) |
| 258 | Providing and laying of suitable size copper PVC insulated armoured power 3½ core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. On Supply side ........ mm² ( The size of cable shall be specifed by the tenderer ) |
| 259 | Providing and laying of PVC jointless flat water proof cable as per BIS,694-1990 (latest with up to date amendements ) of Siemen / Gloster /ICC finollex makesuitable for the pump sets offered from OCB to motor , Motor to starter including all other electric equipment such as thimbles ,flexible pipe , solder , nut & bolt ,cable , glands etc . laid in pipes or trenches under floor . The type & make will be subject to approval of HPSEB authorities . In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost. On Motor side --- mm²( The size of cable shall be specifed by the tenderer). |
| 260 | Providing & laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & copper strips of 20x3mm suitable size conforming to BIS:3043-1987 (latest edition) for above motors & other electrical equipments. |
| 261 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Havells/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable of Siemens/Gloster/ICC make from busbar chamber chamber to capacitor & also including ICTP switches Kilburn/L&T/Standard/Siemen's/Havell's of conforming to 4064-1978 or latest with HRC fuses with two years warrantee. ( KVAR of capacitor to be specified by the Tenderer) |
| 262 | Supply of 100mm dia circular dial pressure gaugeof suitable range of Fiebeg make with all accessories such as stop cock,copper tubing etc. conforming to BIS:3624-1987 latest with up to date ammendments. |
| 263 | Providing & laying G.I. pipes (M) Class as per BIS 1239-2012 ( latest)/GMS pipe 4.00mm thick of suitable size for Column pipe and making connection with R/Main considering site requirements & depth required / available in the P/well.The column pipe shall be be flanged at every 3 metre length as per the requirement of offered pump (to be given by the tenederer) and connecting pipe shall be equal to dia of R/main including tapers, flanges, bends, rubber gaskets,3mm thick nuts & bolts and specials up to 5 mtrs. away from the outer wall of pump house as per layout drawing approved by Engineer-in-Charge. The pipes material shall conform to relevant BIS codes and capable of withstanding field test pressure equal to 1.5 times the operating pressure The complete arrangement shall comprise of:- |
| 264 | Suction pipe ( To be mentioned by tenderer) |
| 265 | Delivery pipe ( To be mentioned by tenderer) |
| 266 | Common header 80 mm dia GMS pipe |
| 267 | Errection of all equipments as per required items i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail