| 1 | Labour only for checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV fittings, LED fitting of any type, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) (or) replecement of complete fitting either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge.NOTES FOR SCH `A’ ITEM NO 1:-(i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’.(ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(iii) Required screws, insulating tapes, internal wiring wire, gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item.(iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. |
| 2 | Supply only 1.5 Sqmm 2 core multi-stranded armoured copper conductor, PVC insulated sheathed flat cable for connecting junction box to street light fitting complete all as specified and directed. |
| 3 | Supply only PVC conduit medium grade 25mm thick for running 2 core cable from junction box to street / flood light fitting including necessary fixing arrangement such as MS clamp of suitable size complete with nuts and bolts all as specified and directed. |
| 4 | Supply only MCB, SP 6 to 32 Amps - 10KA 240 Volts complete all as specified & directed. |
| 5 | S&F in repair rectangular water proof junction boxes for pole with metric knockout for cable entry with MS clamp etc fixing on pole / wall with MS clamps / MS flat iron ( as per site requirement) of size 25x4mm , nuts, bolts, washer and glands, including one No of MCB SP 6 Amps complete all as per specified and directed. |
| 6 | Supply & fix new generation energy saving and environmental friendly long life 150 watt LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source all as specified & directed. |
| 7 | Supply & fix new generation energy saving and environmental friendly long life 60 watt LED flood light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source complete all as specified & directed. |
| 8 | Supply & fix new generation energy saving and environmental friendly long life 70 watt LED flood light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source complete all as specified & directed. |
| 9 | Supply & fix new generation energy saving and environmental friendly long life 30 watt LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source with 100 lumens/watt colour ,temperature 5700-6500K and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device as light source all as specified & directed. |
| 10 | S&F decorative LED Post Top 360 degree light of 20 W with IP65 protection, resistant to impact, anti corrosion, glare-free and beffer uniformity. Product description of Make Crompton product description LPTO-40-WW or equivalent all as specified & directed by Engineer-in-Charge. |
| 11 | S&F decorative LED Post Top 360 degree light of 40 W with IP65 protection, resistant to impact, anti corrosion, glare-free and beffer uniformity. Product description of Make Crompton product description LPTO-40-WW or equivalent all as specified & directed by Engineer-in-Charge. |
| 12 | Taking down carefully existing u/s LT UG cable of size 10 Sqmm to 95 Sqmm of any core 1100V grade PVC/XLPE insulated, PVC sheathed armoured conductor laid in trenches/ on poles through GI protection pipe and old cable covers complete all as specified and directed. (Excavation and earthwork shall be measured and paid for separately under respective items of BOQ) |
| 13 | Supply, laying ,jointing ,testing and commissioning LT UG cable of size 10 Sqmm 2 core 1100V grade PVC insulated, PVC sheathed armoured aluminium conductor laid in trenches/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminum lugs complete all as specified and directed.Note-Excavation, earthwork, sand cushioning, GI pipe protection, PCC cable cover shall be measured and paid separately under respective items of BOQ. |
| 14 | All as per item No 11 here-in-before but cable of size 16 sqmm 2 core. |
| 15 | All as per item No 11 here-in-before but cable of size 25 sqmm 2 core. |
| 16 | All as per item No 11 here-in-before but cable of size 25 sqmm 4 core. |
| 17 | All as per item No 11 here-in-before but cable of size 35 sqmm 3.5 core. |
| 18 | All as per item No 11 here-in-before but cable of size 50 sqmm 3.5 core. |
| 19 | Excavation, in trenches in soft/loose soil not exceeding 1.5 m in width and not exc 1.5 m in depth for laying under ground cable and getting out complete all as specified & directed. |
| 20 | Excavation, in trenches in soft/loose soil not exceeding 1.5 m in width and exc 1.5 m in depth but not exc 3.00m depth for laying under ground cable and getting out complete all as specified & directed. |
| 21 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick each ,filling back in trenches after laying of cable and tested complete all as specified & directed. |
| 22 | Removal of surplus excavated material to a distance n exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 23 | Material & Labour for Sand cushioning to under ground cable with clean dry sand locally available with layer of sand 8cm thick before laying of cable and 15 cm after laying of cable complete all as specified & directed.Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I. |
| 24 | Material & Labour for Un-reinforced pre cast concrete cable covers class LV, type-1, flat, of size 250mm x 150 mm x 40mm for cable protection including taking down old complete all as specified & directed |
| 25 | Supply & Fixing of Steel tubing light grade galvanised of size 40mm dia laid in trench or fixed to wall/pole for cable protection, complete all as specified & directed. |
| 26 | Material & Labour for street light bracket made out of 40mm dia GI pipe light grade tubing 1.2 mtr long bent to required shape including 02 Nos of MS clamp of size 450x50x5mm flat and suitable size of nuts and bolts complete all as specified & directed. |
| 27 | Material and labour for dressing of LT panels/Bus bars/pole by excavating the cable loop, dressing of cable properly by cutting the damaged part and dressed with insulation tape, thimble/lugs, nuts, bolts and washers etc. and making good the surface by ruturning/filling/removal of excavated soil complete all as specified and as directed.Note : Earth work involved to be deemed inclusive in the job |
| 28 | Material and labour for dressing of LT pole by excavating the cable loop, dressing of cable properly by cutting the damaged part and dressed with insulation tape, thimble/lugs, nuts, bolts and washers etc. complete all as specified and as directed.Note : Earth work involved to be deemed inclusive in the job |
| 29 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion. |
| 30 | Supply and fix PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) including taking down existing unserviceable pole complete all as dierected and specified by Engineer-in-charge. |
| 32 | M&L Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) for foundation work including necessary form work and finished the surface with plastering using extra cement complete all as pecified and as directed. |
| 33 | M&L Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) for foundation work including necessary form work and finished the surface with plastering using extra cement complete all as pecified and as directed. |
| 34 | M&L Cement concrete concrete (1:2:4) type B1 using 20mm graded stone aggregate, rounded or chamfered on edges including necessary form work and finished the surface with plastering using extra cement complete all as pecified and as directed. |
| 35 | Dismantling of old security light bracket including cutting of welding, if required, fixed to steel tubular pole/ wall at any height with electric connection and refixing the security light bracket after repairing the same pole/ wall including new nut bolts, washers, clamp as required at site and all as directed by Engr-in-Charge Please Enable Macros to View BoQ information |