| 1 | Supply, erection,testing and commissioning of HOT Dip galvanized octagonal steel pole of 11 mtr height and made out of 3 mm thick sheet PCD 320 mm having bottom 200 mm A/F & top 100 mm A/F with built in connector box of size 500 mm x 100 mm with ring of minimum 250 mm width made of 4 mm thick Sheet on window cover for anti theft arrangement at 2500 mm height from base plate, M.S base plate of size 320 mm x 320mm x 20 mm thick, double overhang G.I. bracket made of 3.60 mm thick M.S. pipe with 400 mm long top galvanized tube of suitable dia to accommodates the fittings, on existing RCC foundation i/c supply of 4 nos. M-24x850mm long (150 mm top threaded portion & 100mm bend), G.I foundation bolts(L Type) & nuts (EN 8-grade) 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 320 mm x 320 mm x 4 mm thick, having 4 Nos. 26 mm dia. holes to match with PCD of pole and base plate, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking, numbering of pole etc. complete as per drawing & technical specifications attached including following accessories mounted on inbuilt control box having flush cover with 2 Nos mounting strips with tapped holes:- (a). 6 mm thick phenolic laminated sheet/ bakelite sheet inside the window mounted on the existing mounting strips inside the flush door. (b). Supply & fixing 63 Amp terminal block suitable for 16 sq. mm conductor- 4 nos. & shorting links-5 nos. on DIN Channel i/c pdg and fixing DIN channel of suitable length- 2 nos. on existing laminated sheet (c) terminal suitable for 6 SWG G.I Wire/1.5 sq. mm wire(d) 6 Amp, SP MCB,10 KA, ‘C’ Series – 2 nos. including mounting on din channel, earth stud 2 nos. welded at suitable height i/c washers & nuts etc. (e). Suitable arrangement for saddling of incoming / outgoing cables i/c lugs/thimbles etc as required. |
| 2 | Supply, erection,testing and commissioning of HOT Dip galvanized octagonal steel pole of 11 mtr height and made out of 3 mm thick sheet PCD 320 mm having bottom 200 mm A/F & top 100 mm A/F with built in connector box of size 500 mm x 100 mm with ring of minimum 200 mm width made of 4 mm thick Sheet on window cover for anti theft arrangement at 2500 mm height from base plate, M.S base plate of size 320 mm x 320mm x 20 mm thick, triple overhang G.I. bracket made of 3.60 mm thick M.S. pipe with 400 mm long top galvanized tube of suitable dia to accommodates the fittings, on existing RCC foundation i/c supply of 4 nos. M-24x850mm long (150 mm top threaded portion & 100mm bend), G.I foundation bolts(L Type) & nuts (EN 8-grade) with 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 320 mm x 320 mm x 4 mm thick, having 4 Nos. 26 mm dia. holes to match with PCD of pole and base plate, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking, numbering of pole etc. complete as per drawing & technical specifications attached including following accessories mounted on inbuilt control box having flush cover with 2 Nos mounting strips with tapped holes:- (a). 6 mm thick phenolic laminated sheet/ bakelite sheet inside the window mounted on the existing mounting strips inside the flush door. (b). Supply & fixing 63 Amp terminal block suitable for 16 sq. mm conductor- 4 nos. & shorting links-5 nos. on DIN Channel i/c pdg and fixing DIN channel of suitable length- 2 nos. on existing laminated sheet (c) terminal suitable for 6 SWG G.I Wire/1.5 sq. mm wire(d) 6 Amp, SP MCB,10 KA, ‘C’ Series – 3 nos. including mounting on din channel, earth stud 2 nos. welded at suitable height i/c washers & nuts etc. (e). Suitable arrangement for saddling of incoming / outgoing cables i/c lugs/thimbles etc as required. |
| 3 | Providing and laying in position, M25 reinforced cement concrete foundation of size 750mm long x 750mm wide and 1800 mm deep i/c excavation of earth, refilling, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1900 mm long (approx.)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2900 mm long (approx.)-10 Nos. (With 150 mm spacing) i/c centering & shuttering as required positioning of foundation bolts and providing 63 mm (OD) 2 Nos. DWC pipe suitable length each for cable entry and exit etc complete as required. |
| 4 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt utput . LM79 & LM80 Test report from NABL lab for all testing required or LED fixtures as per BIS shall be submitted. Shape size and CCT shall be approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 200 watt |
| 5 | Supplying and drawing following sizes of 1.1 KV grade FRLS PVC insulated copper conductor Single core cable in the existing surface/recessed steel conduit as required.a) 3 x 1.5 Sq.mm |
| 6 | Supply of following sizes of XLPE aluminium conductor armoured power cable of 1.1 KV grade confirming to IS 7098(Part 1) with upto date amendment as per technical specfication attached. |
| 7 | 4 x 16 Sq.mm |
| 8 | 4 x 25 sq.mm |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 10 | Upto 35 sq. mm |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.Note:- Excavation shall also include pacca cutting wherever applicable as per site requirement and nothing extra shall be paid on this account |
| 12 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 13 | Supply, boring and laying of HDPE DWC pipes (ISI) marked of the 90 mm dia size confirming to IS:4984 with pressure rating of 6KG/Sq.cm by trench less technology with no dig. Method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning, rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe. etc. complete as required. |
| 14 | 90 mm dia |
| 15 | Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe as required. |
| 16 | Up to 35 Sq.mm |
| 17 | laying overhead of 4 x 16 sq. mm XLPE aluminium conductor armoured power cable of 1.1 KV grade, i/c connection, testing etc complete as required. |
| 18 | Providing and fixing 100 A rating and 30KA breaking capacity FPMCCB (Ics= Icu) with thermomagnetic release and terminal spreaders inside a suitable size hot press moulded SMC junction box of inside size 350x270x190, side hinged door type with provision for 3 phase cable entry,exit & external bracket for fixing on wall/pole including drilling holes, making connections, testing etc. complete as required. |
| 19 | Supply installation, testing & commissioning of floor mounted free standing type L.T. cubical main feeder pillar duly compartmentalized (outdoor type) made out of 2 mm thick MS CRCA sheet, 7 tank process powder coated with 4 nos. x 600 mm long legs made of M.S angle iron of size 40 mm x 40 mm x 5 mm thick along with frame & legs suitably grouted in foundation i/c connection inter connection of the accessories mounted there on with suitable size of copper wire/strip with thimble/lugs, earthing the body of the feeder pillar i/c supplying & fixing of the following items and as per technical specification enclosed. a) 100 A,36KA,FPMCCB (Ics= Icu) - 1 No (incomer). b) Volt meter (0-500V) 96 Sq.mm with selector switch – 1 Setc) Amp-meter (0-100A) 96Sq.mm with selector switch & 100/5 Amp ratio CTS – 1 Setd) Indication Lamp (RYB) with control HRC fuse with fuse fitting- 1 set.e) 63 A,16KA,FPMCCB (Ics= Icu) (out going circuit) - 3 Nos.f) 6 amp SP MCB – 1 No.g) 3 pole Power contactor of AC-3 rating 100 Amp. -1 No. h) Astronomical Time switch – 1 No.i) Auto/Manual toggle switch – 1 No.j) 100 amp, 4 strip aluminium busbar – 1 Setk) Danger Notice plate – 1 No.l) 6 Pin 15 A Switch & Socket outlet - 1 Set m) LED Lighting inside the feeder pillar Note: PCC(1:2:4) Foundation height of 750 mm duly plastered & finished having top outer edges 20 cm beyond all round the edges of 40x5 angle iron frame shall be made as per site requirement for which nothing extra shall be paid. |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 21 | 4 X 16 sq. mm (28mm) |
| 22 | 4x25 sq. mm (28mm) |
| 23 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 24 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 25 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for conneciton etc. as required. |
| 26 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. Please Enable Macros to View BoQ information |