| 1 | Providing services of skilled and unskilled staff for operation and routine maintenance of 33/0.433 KV indoor electric substation& switch yard i/c all HT & LT panel, transformer installed at sub-station and 200 KVA 2 Nos. auto/manual operated DG Sets round the clock by deploying minimum staff as given in terms and conditions on all working days including Sunday & holidays etc. complete as required.(Electrician -3 Nos. & Khallasi-3 Nos. including Reliever) | Providing services of skilled and unskilled staff for operation and routine maintenance of 33/0.433 KV indoor electric substation& switch yard i/c all HT & LT panel, transformer installed at sub-station and 200 KVA 2 Nos. auto/manual operated DG Sets round the clock by deploying minimum staff as given in terms and conditions on all working days including Sunday & holidays etc. complete as required.(Electrician -3 Nos. & Khallasi-3 Nos. including Reliever) |
| 2 | Providing services for day to day maintenance and upkeeping of all the internal and external electrical installations such as compound light, street light, security light, DB's, switch board, main board, panel and all type of light fixtures like holder, bracket light, fancy light, mirror light, fluorescent fitting, LED light fitting, ceiling fan, wall fan, exhaust fan, wiring etc. including removal /rectification of the fault, attending day to day complaints, pump operation recording and monitoring of the complaints on complaint register at site as per the norms of the department etc. by deploying minimum staff as given in terms and conditions on all working days including Sunday & holiday and as per the direction of Engineer-in-charge complete as reqd. (Wireman- 3 Nos. and Khallasi- 2 Nos. including Reliever) | Providing services for day to day maintenance and upkeeping of all the internal and external electrical installations such as compound light, street light, security light, DB's, switch board, main board, panel and all type of light fixtures like holder, bracket light, fancy light, mirror light, fluorescent fitting, LED light fitting, ceiling fan, wall fan, exhaust fan, wiring etc. including removal /rectification of the fault, attending day to day complaints, pump operation recording and monitoring of the complaints on complaint register at site as per the norms of the department etc. by deploying minimum staff as given in terms and conditions on all working days including Sunday & holiday and as per the direction of Engineer-in-charge complete as reqd. (Wireman- 3 Nos. and Khallasi- 2 Nos. including Reliever) |
| 3 | Providing services for supervision of operation and maintenance of Substation, Pump house and external/ Internal electrical works of AIIMS Residential campus by deployment of Supervisor of Highly skilled grade as per schedule and directed by Engineer-in-charge. | Providing services for supervision of operation and maintenance of Substation, Pump house and external/ Internal electrical works of AIIMS Residential campus by deployment of Supervisor of Highly skilled grade as per schedule and directed by Engineer-in-charge. |
| 4 | Comprehensive Maintenance/servicing & testing of 1 MVA 33/0.433 KV oil immersed outdoor type transformer to ensure proper functionality in all respect and entire satisfaction of engineer in charge. (a) Rectification and stopping of oil lekage i/c replacement of gasket set if required.(b) Servicing and checking of on load tap changer.(c) Low voltage testing i/c mangetic balance, voltage ratio, no load current, winding resistance etc. complete as per requirement.(d) Demoisturing of transformer core as per requirement.(e) Maintenance and repair/replacement of material like Buchholz Relay, Winding Temp. Indicator with 2 Set of Contacts (Micro Switch Type), Oil Temp. Indicator, Winding Temp. Indicator, Magenetic Oil Level Gauge, Insulator(36 KVA Grade), Detachable undrilled Gland Plate, Terminal Bushing(HT), HT End Termination Kit 33 KV(In door & Outdoor Type), HT Straight through Jointing Kit, coil Replacement etc for making the transformer functional as required .(f) Transformer oil topup and filteration as per schedule.(g) replacement of silica gel as per requirement and any other work indicated by Engineer in charge. Note:- (1) Uplifting and lowering of transformer from substation to repair center and fro is also inclusive.(2) Servicing and testing of Transformer to be got executed through OEM/ OEA/ Authorized dealer. (3) Providing Electrical valid NOC /Concern to operate of Substation complete with all procedure from state or central Govt as required. | Comprehensive Maintenance/servicing & testing of 1 MVA 33/0.433 KV oil immersed outdoor type transformer to ensure proper functionality in all respect and entire satisfaction of engineer in charge. (a) Rectification and stopping of oil lekage i/c replacement of gasket set if required.(b) Servicing and checking of on load tap changer.(c) Low voltage testing i/c mangetic balance, voltage ratio, no load current, winding resistance etc. complete as per requirement.(d) Demoisturing of transformer core as per requirement.(e) Maintenance and repair/replacement of material like Buchholz Relay, Winding Temp. Indicator with 2 Set of Contacts (Micro Switch Type), Oil Temp. Indicator, Winding Temp. Indicator, Magenetic Oil Level Gauge, Insulator(36 KVA Grade), Detachable undrilled Gland Plate, Terminal Bushing(HT), HT End Termination Kit 33 KV(In door & Outdoor Type), HT Straight through Jointing Kit, coil Replacement etc for making the transformer functional as required .(f) Transformer oil topup and filteration as per schedule.(g) replacement of silica gel as per requirement and any other work indicated by Engineer in charge. Note:- (1) Uplifting and lowering of transformer from substation to repair center and fro is also inclusive.(2) Servicing and testing of Transformer to be got executed through OEM/ OEA/ Authorized dealer. (3) Providing Electrical valid NOC /Concern to operate of Substation complete with all procedure from state or central Govt as required. |
| 5 | Comprehensive Maintenance & servicing of LT panel & Air Circuit Breaker installed in LT panel including resetting and testing of under voltage relay, closing coil, opening coil, calibration, control wiring, Busbar etc. complete as required and includes replacement of non functional NO/NC switch, Breaker not functional push button and cover, non functional capacitor of APFC panel, 14 relay APFC controller similar to existing as required and as per direction of Engineer-in- charge.(a) 1250 Amp ACB = 03 Nos (b) 800 Amp ACB = 01 Nos | Comprehensive Maintenance & servicing of LT panel & Air Circuit Breaker installed in LT panel including resetting and testing of under voltage relay, closing coil, opening coil, calibration, control wiring, Busbar etc. complete as required and includes replacement of non functional NO/NC switch, Breaker not functional push button and cover, non functional capacitor of APFC panel, 14 relay APFC controller similar to existing as required and as per direction of Engineer-in- charge.(a) 1250 Amp ACB = 03 Nos (b) 800 Amp ACB = 01 Nos |
| 6 | Comprehensive Maintenance & servicing of complete HT VCB panel including resetting and testing of under voltage relay, closing coil, opening coil, calibration, Busbar maintenance, relay testing and maintenance, DC charger etc. complete as required and replacement of not functional Digital powerfactor meter, frequency meter, selector switch handle Auto/ Manual, Ammeter/voltmeter selector switch, calibration of all relay and replacement of all non functional relay and controller as required and as per direction of Engineer-in- charge.(a) 1250 Amp VCB= 03 Nos . Note:- (1) Servicing and testing of HT VCB panel to be got executed through OEM/ OEA/ Authorized dealer. | Comprehensive Maintenance & servicing of complete HT VCB panel including resetting and testing of under voltage relay, closing coil, opening coil, calibration, Busbar maintenance, relay testing and maintenance, DC charger etc. complete as required and replacement of not functional Digital powerfactor meter, frequency meter, selector switch handle Auto/ Manual, Ammeter/voltmeter selector switch, calibration of all relay and replacement of all non functional relay and controller as required and as per direction of Engineer-in- charge.(a) 1250 Amp VCB= 03 Nos . Note:- (1) Servicing and testing of HT VCB panel to be got executed through OEM/ OEA/ Authorized dealer. |
| 7 | Comprehensive Maintenance & servicing of electrical distribution panel in pump house,fountain ,STP, guest house, banglow, Type 5A,4A,3A,2A,2B,1A,1B panel with all accessories includes replacement of not working contactor , Auxillary contactor, CT, Electronic Timer, single phase preventor etc of 2 nos pump panel and 9 nos buildings power panel Busbar, connection, fabrication of damaged or rusted panel box as same dimension as existing including all accessories as required and as per direction of Engineer-in- charge. | Comprehensive Maintenance & servicing of electrical distribution panel in pump house,fountain ,STP, guest house, banglow, Type 5A,4A,3A,2A,2B,1A,1B panel with all accessories includes replacement of not working contactor , Auxillary contactor, CT, Electronic Timer, single phase preventor etc of 2 nos pump panel and 9 nos buildings power panel Busbar, connection, fabrication of damaged or rusted panel box as same dimension as existing including all accessories as required and as per direction of Engineer-in- charge. |
| 8 | Comprehensive Maintenance & servicing of Diesel generator 200 KVA includes replacement of all filters, engine oil, coolent during half yearly servicing and replacement of parts which gets damage or not functional during operation, engine servicing, battery charger, complete report of B type checkup of DG set to be submitted half-yearly etc. complete as required and as per direction of Engineer-in- charge excluding Diesel. Note:- (1) Servicing and testing of Diesel generator to be got executed through OEM/ OEA/ Authorized dealer. | Comprehensive Maintenance & servicing of Diesel generator 200 KVA includes replacement of all filters, engine oil, coolent during half yearly servicing and replacement of parts which gets damage or not functional during operation, engine servicing, battery charger, complete report of B type checkup of DG set to be submitted half-yearly etc. complete as required and as per direction of Engineer-in- charge excluding Diesel. Note:- (1) Servicing and testing of Diesel generator to be got executed through OEM/ OEA/ Authorized dealer. |
| 9 | Material and labour for Rewinding of following motor with super enamelled copper winding wire having appropriate class of insulation to the existing class including dismantling of motor pump set and after rewinding refixing, recoupling with driven equipment, commssioning complete all as specified and directed by Engineer-in-charge. | Material and labour for Rewinding of following motor with super enamelled copper winding wire having appropriate class of insulation to the existing class including dismantling of motor pump set and after rewinding refixing, recoupling with driven equipment, commssioning complete all as specified and directed by Engineer-in-charge. |
| 10 | 1.5 HP 3 phase monoblock motor | 1.5 HP 3 phase monoblock motor |
| 11 | Cooling tower 2HP motor | Cooling tower 2HP motor |
| 12 | 3 HP Motor | 3 HP Motor |
| 13 | 5 HP 3 phase monoblock submersible motor | 5 HP 3 phase monoblock submersible motor |
| 14 | 30 HP 3 phase monoblock motor | 30 HP 3 phase monoblock motor |
| 15 | Material & Labour for Lifting of unserviceable electric driven submersible pump motor set of Capacity 5 HP from bore well alongwith GI column pipe & submersible cable carefully without damaging complete depth of bore for repair/ rewinding the submersible pump set including lowering of repaired pump set alongwith existing GI column pipe/roll & submersible cable in bore well making all connecting and testing complete all as required & specified and as per direction of Engineer-in-Charge. | Material & Labour for Lifting of unserviceable electric driven submersible pump motor set of Capacity 5 HP from bore well alongwith GI column pipe & submersible cable carefully without damaging complete depth of bore for repair/ rewinding the submersible pump set including lowering of repaired pump set alongwith existing GI column pipe/roll & submersible cable in bore well making all connecting and testing complete all as required & specified and as per direction of Engineer-in-Charge. |
| 16 | Replacement of 5HP Submersible pump 3 phase automatic DOL starter incorporating Heavy duty 4 pole Contactor with Overload relay, auto start switch, Single phase preventer, 3 position selector switch for SPP/Auto/SPP Manual/ Ammeter & Voltmeter with selector switch, RYB LED indicator, Motor ON and TRIP LED indicator, TP \\"C\\" Curve MCB for short circuit protection complete all as specified and directed by Engineer. | Replacement of 5HP Submersible pump 3 phase automatic DOL starter incorporating Heavy duty 4 pole Contactor with Overload relay, auto start switch, Single phase preventer, 3 position selector switch for SPP/Auto/SPP Manual/ Ammeter & Voltmeter with selector switch, RYB LED indicator, Motor ON and TRIP LED indicator, TP \\"C\\" Curve MCB for short circuit protection complete all as specified and directed by Engineer. |
| 17 | Repair & maintenance of HT line 33KV double pole structure by replacement of complete set of Air Break (AB) switch including mounting bracket , insulator base, connecting wire and cleaning of rusted 4 nos poles & painting with oil paint along with red oxide primer, replacement of all power iinsulator, Repair of DO operating handle & lock arrangement with proper insulation in operating handle, repair of rusted pole with proper support system & welding as required, providing 1.25 inchs bolder in switch yard area for maintain height level from ground for preventing electrical shock & safety at switch yard and taking permission from state electricity board for power shutdown during work execution with proper safety of manpower including all accessories as required for execution of work and as per direction of Engineer Incharge. | Repair & maintenance of HT line 33KV double pole structure by replacement of complete set of Air Break (AB) switch including mounting bracket , insulator base, connecting wire and cleaning of rusted 4 nos poles & painting with oil paint along with red oxide primer, replacement of all power iinsulator, Repair of DO operating handle & lock arrangement with proper insulation in operating handle, repair of rusted pole with proper support system & welding as required, providing 1.25 inchs bolder in switch yard area for maintain height level from ground for preventing electrical shock & safety at switch yard and taking permission from state electricity board for power shutdown during work execution with proper safety of manpower including all accessories as required for execution of work and as per direction of Engineer Incharge. |
| 18 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 19 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 22 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 23 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 24 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit as required. | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | 32 mm | 32 mm |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 27 | 5/6 A switch | 5/6 A switch |
| 28 | 15/16 A switch | 15/16 A switch |
| 29 | 3 pin 5/6 A socket outlet | 3 pin 5/6 A socket outlet |
| 30 | 6 pin 15/16 A socket outlet | 6 pin 15/16 A socket outlet |
| 31 | Bell push | Bell push |
| 32 | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 33 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 34 | 3 Module (100mmX75mm) | 3 Module (100mmX75mm) |
| 35 | 6 Module (200mmX75mm) | 6 Module (200mmX75mm) |
| 36 | 8 Module (125mmX125mm) | 8 Module (125mmX125mm) |
| 37 | 12 Module (200mmX150mm) | 12 Module (200mmX150mm) |
| 38 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 39 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 40 | Supplying and fixing call bell/ buzzer suitable forsingle phase, 230 V, complete as required. | Supplying and fixing call bell/ buzzer suitable forsingle phase, 230 V, complete as required. |
| 41 | Supplying and fixing PVC batten/ angle holderincluding connections etc. as required. | Supplying and fixing PVC batten/ angle holderincluding connections etc. as required. |
| 42 | Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. | Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. |
| 43 | 250 A,36KA,FPMCCB | 250 A,36KA,FPMCCB |
| 44 | 400 A,50KA,FPMCCB | 400 A,50KA,FPMCCB |
| 45 | 630 A,50KA,FPMCCB | 630 A,50KA,FPMCCB |
| 46 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 47 | Triple pole and neutral | Triple pole and neutral |
| 48 | Supplying and fixing TP sheet steel enclosure onsurface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. | Supplying and fixing TP sheet steel enclosure onsurface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 49 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 50 | 18 watt | 18 watt |
| 51 | LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ).Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following bodymaterial and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/ 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color atching) <3, Maximum power consumption should not more than thespecified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector | LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ).Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following bodymaterial and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/ 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color atching) <3, Maximum power consumption should not more than thespecified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 52 | 5 - 7 watt | 5 - 7 watt |
| 53 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 54 | 18- 22 Watt | 18- 22 Watt |
| 55 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 56 | 120 watt | 120 watt |
| 57 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 58 | 250 watt | 250 watt |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail