| 1 | DT ( Supply Part ) |
| 2 | Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 3 | Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 4 | Supply of 180mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs |
| 5 | Supply of 9 Mtr. Long Pole,ST-410 SP33) |
| 6 | Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 7 | Supply of GI Channel/Angle/Flat of sizes including clamps |
| 8 | Supply of Galvinized Nuts and Bolts. |
| 9 | Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 10 | Supply of 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 11 | Supply of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 12 | Supply of GI Barbed Wire for Anti Climbing |
| 13 | Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 14 | Supply of Painting of Poles Red Oxide |
| 15 | Supply of Painting of Poles Aluminium Paint |
| 16 | Supply of 50 mm² ACSR Conductor |
| 17 | Transformer Fencing of size 12x6x6 with GI wire mesh of size 50x50mm with gravels inside the fencing |
| 18 | Installation/Testing /Commissioning Part of Substation. |
| 19 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 20 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 21 | 180mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for DTs |
| 22 | 9 Mtr. Long Pole,ST-410 SP33) |
| 23 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 24 | GI Channel/Angle/Flat of sizes including clamps |
| 25 | Galvinized Nuts and Bolts. |
| 26 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 27 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 28 | LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 29 | GI Barbed Wire for Anti Climbing |
| 30 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 31 | Painting of Poles Red Oxide |
| 32 | Painting of Poles Aluminium Paint |
| 33 | 50 mm² ACSR Conductor |
| 34 | Transformer Fencing of size 12x6x6 with GI wire mesh of size 50x50mm with gravels inside the fencing |
| 35 | Dismantalling Part |
| 36 | Dismentlling and re-erection of Distribution Transformer on new structure |
| 37 | Dismentlling of old substations alied materials and right back to Divisional Store PDD Choglamsar Please Enable Macros to View BoQ information |