| 1 | Electrical work as per Sheet 1 BOQ Estimate for Creation of 63 KVA Sub-Station along with HT/LT Network at Naik Mohalla Chitripora NHO Zahoor Ah. Bhat S/O. Mohd Abdullah Bhat under CDF Scheme # ITEM DESCRIPTION UNIT QTY ADV. RATE Total |
| 2 | Installation, Commissioning of 63 kVA Transformer along with loading, unloading charges from Divisional Store to Site |
| 3 | Supply,Installation testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 4 | SITC LT Fuse of suitable capacity (Please refer Tender Drawing of Fuse set) including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 5 | SITC of 11KV 3 Phase Horn Gap fuse set 3Phase 200 A including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 6 | SITC of 11 KV LA SET 9 KVA ,10 KA,LA WITH Polymer ,Porcelain Housing Station Type including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 7 | SITC of 185 mm² Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS typeincluding loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 8 | Providing and Fixing of Alumunium Thimbles of sizes |
| 9 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC Standard and approved drawings. |
| 10 | SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 11 | SITC of 9 Mtr. Long Pole ( ST-410 SP33) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard of Sub-Station part |
| 12 | SITC of 9 Mtr. Long Pole ( ST-410 SP33) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard of HT Part |
| 13 | Providing of Cement bottoming 1:2:4 mix as per Standards 0.48 cum /pole muffing 20 cm above ground level ,including plaster and curing of concrete for ( 9 Mtr ST Pole ) as per REC Standard and approved Drawing |
| 14 | SITC of 8 Mtr. Long Pole (ST-410 SP15) with base plate and cap including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 15 | Providing of Cement bottoming 1:2:4 mix as per Standards 0.40 cum / pole , muffing 20 cm above ground level ,including plaster and curing of concrete for ( 8 Mtr ST Pole) as per approved drawing and REC. standard |
| 16 | Supply, Transportation, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm² ACSR Conductor (Weasel) along with fitting complete as per approved drawing and REC. standard |
| 17 | SITC of 11 KV pin insulator Complete (Polymer/Porcelain) 5 KN With Pins including loading, unloading,insurance carriage and delivery at Site as per approved drawing and REC. standard |
| 18 | Supply, installation, Testing and Commissioning of 35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth) as per Rec. standard |
| 19 | Supply, installation, Testing and Commissioning Heat Shrinkable Outdoor Cable Termination Kit as per the REC. Standard |
| 20 | Providing and Fixing of Suspension/Tension Clamp with eye hook as per REC. Standard |
| 21 | Supplying and erection of GI channel (100x50x6 mm) ,(75x40x6 mm) , GI Angle( 50x50x6 mm), 50X50X6 mm angle support including clamps for Sub-Station Frame / GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC approved Drawings. |
| 22 | Providing and Fixing of Galvanized Nuts and Bolts |
| 23 | Supply and erection of Danger Plate with clamps (writing in English and Regional Language ) as per approved drawing and REC. standard |
| 24 | Supply and fixing of anti-climbing Device with Clamps as per approved drawing and REC. standard |
| 25 | Providing and Fixing of LT Shackle with Muki Clamps (50*6mm) complete as per REC Standard and approved drawings |
| 26 | Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) |
| 27 | Sign Board Mentioning Name of Village ,Name of Work/scheme, Year of Implementing ,Implementing Agency PDD KPDCL Div Shopian & Name of Contractor |
| 28 | Geo Tagged Photographs of high resolution (Pre and Post Photographs) Both hard and soft copy (for e-compendium) 4 Photographs Per site |
| 29 | Supply,Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawing and REC. standard Total 680099.65 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Technical Officer Executive Engineer, ED Shopian Please Enable Macros to View BoQ information |