| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in Soft / loose soil complete all as specified & as directed. |
| 2 | Demolition of brick work or stone boulder masonry / pre-cast cement concrete block masonary built in cement mortar complete all as specified & directed. |
| 3 | Demolition of reinforced cement Concrete of any description and in any position as in, tie band of wall etc complete all as specified & directed. |
| 4 | M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass concrete complete all as specified & directed. |
| 5 | M&L for Reinforced cement concrete, Design Mix M-25 using 20 mm graded crushed stone aggregates as in foundations including rafts, column footings, plinth beams, etc complete all as specified & directed. |
| 6 | M&L for Reinforced cement concrete M-25 Design Mix using 20 mm graded Crushed stone aggregates as in columns, pillars, piers, posts and struts etc complete all as specified & directed. |
| 7 | M&L for Reinforced cement concrete, Design Mix M-25 using 20 mm graded Crushed stone aggregates as in lintel band / roof band over block masonary wall etc complete all as specified & directed. |
| 8 | M&L for Formwork to sides of concrete foundations, column footings, plinth beams, and similar works, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed. |
| 9 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, for square, rectangular or polygonal, rough finished Square, rectangular or polygonal surfaces of concrete complete all as specified & directed. |
| 10 | M&L for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide finished rough finished surface of concrete complete all as specified & directed. |
| 11 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & directed. |
| 12 | M&L for mild steel TMT bars 5 mm dia and over & upto and including 10 mm dia as in stirrups, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia orsecuring with clips complete all as specified & directed. |
| 13 | M&L for Pre-cast cement concrete (1:3:6) type C1 using 20mm graded Crushed stone aggregate as in solid block masonary exceeding 10 cm width and setting in cement mortar (1:6) complete all as specified & directed. |
| 14 | M&L for Rendering 15mm thick in cement mortar (1:4) over brick or concrete wall surfaces finished even and fair complete all as specified & directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 16 | M & L for Mild steel work as in fencing posts and struts including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. |
| 17 | S&F Galvanised 2 strand steel barbed wire with 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc., complete all as specified & directed. (Notes : Each line of wire to be measured for payment) |
| 18 | M&L for Preparation of steel surfaces and treating with tar or coal tar black paint to small articles such as stop, covers, gully gratings, hold fast, ends of posts, back of chowkats etc., area not exceeding 0.10 Sqm each complete all as specified & directed. |
| 19 | M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 20 | M&L for preparation of newly plastered surfaces of walls and applying two coats of Cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 21 | M&L for Hot dipped Galvanised Iron Punched tape concertina coil 600mm dia, openable (in stretched position) and 10m openable length having 50Nos of turns for every 6m length, spring core wire 2.5mm thick of tensile strength 165kg/sqmm with tape 0.52mm thick and weight 43.478 gms/mtr, including all fittings like fastener clip, steel lug rings, G I wire etc and fixing the same to Y- shaped angle iron with horizental reinforced barbed tape wire stud tied with G I staples and G I clips to retain horizental all as specified and directed Note : (i) M S angle iron & barbed wire shall be measured & paid seperately(ii) The length of coil after stretching and fixing it place shall be measured for payment purpose. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soil complete all as specified & directed. |
| 23 | Removing excavated material to a distance not exceeding 50 m & depositing where directed at a level not exc 1.5m above the starting point complete all as specified & directed. |
| 24 | Removing building debris materials etc., to a distance exc 900m but n. exc 1000m, out of the MD land, including loading, unloading and stacking at the destination complete all as specified & directed. (1 Metric tonne shall be consider as One load and shall all as per the data as given in Ser no 1 to 16 of SSR Part II 2020 serial page no 21) |
| 25 | Demolition of PVC drain pipes 75 mm dia including fittings or similar work complete all as specified and directed. |
| 26 | S & F 3- layer PPR Polypropylene random copolymer) concealed pipes 75mm outer dia pipe, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified & directed. |
| 27 | S & F Making connection of PPR distribution branch with PPR main 50 to 75mm outer dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified & directed. |
| 28 | M & L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and includes portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc., complete all as specified & directed. |
| 29 | M & L for preparation of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth and applying two coats of black bituminous paint complete all as specified & directed. |
| 30 | M&L for Plain Cement Concrete (1:4:8) type D2 using 40mm graded Crushed stone aggregate as in foundation filling and mass concrete complete all as specified & directed. |
| 31 | M&L for cement concrete (1:2:4) type B2 using 40 mm graded Crushed stone aggregate in surface channels and drains complete all as specified and as directed. |
| 32 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc., complete all as specified and as directed.(Note:- Inner Girth shall be measured for payment) Please Enable Macros to View BoQ information |