| 1 | Fire fighting System(Note-The contractor shall prepare the detailed drawings and scheme for the Fire Fighting System and submit the same to the Engineer-in-Charge for review and approval before execution of the work. After approval from the Engineer-in-Charge, the contractor shall obtain final approval from the Fire Department and then proceed with the installation.) |
| 2 | Providing and fixing of FIRE EXTINGUISHER, ABCPowder type (stored pressure) asper IS:15683 completewithall accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 3 | 6 Kg. Capacity |
| 4 | Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 5 | 4.5 Kg. Capacity |
| 6 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 7 | Tripple layer tanks (5000x4 No. = 20000 ltrs) |
| 8 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 9 | 100 mm internal diameter |
| 10 | Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 11 | Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. |
| 12 | Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect. |
| 13 | Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect. |
| 14 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete |
| 15 | 80 mm i/d check valve |
| 16 | Providing and fixing S.S Pressure Gauge complete as required complete in all respect. |
| 17 | Dial diameter 100mm calibration 0-16 |
| 18 | Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect For 50mm to 150 mm pipe line |
| 19 | Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 20 | 100 mm internal diameter |
| 21 | Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects. |
| 22 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. |
| 23 | 1200 mm wide x 900 mm high x 400 mm deep Size |
| 24 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 25 | 100 mm i/d |
| 26 | Construction of Platform complete as per specification & as desired by Engineer-in-charge. (For 5000 ltr Water Tank) |
| 27 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 28 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 29 | Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. |
| 30 | 32mm i/d |
| 31 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball |
| 32 | Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 33 | Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm diaflanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank). |
| 34 | Two Way inlet connection |
| 35 | Terrace Pump S/I/T/C of Mono Block Terrace fire Pump along with drive of motor capacity 450 LPM against at 35 mtrs Head of 20 mtrs to get pressure of 3.50 Kg/sqm at top most hydrant with MS frame and clamps as neceesry for fixing the pumps on top of slab of Reputed Make pump, 3 Phase Moc:CI casing CI Impeller witheith machnical seal complete in all respects . |
| 36 | 450 LPM AT 35 M HEAD |
| 37 | Installation of HVAC work (VRF System 48HP) |
| 38 | Variable Refrigerant Volume System |
| 39 | Supplying, installation, testing and commissioning of Air Cooled VRV/VRF units with scroll Compressor capable of modulating capacity i.e. it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating & cooling both. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish.The outdoor unit shall have scroll compressors and be able to operate even in case of breakdown of one of compressor. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping etc. Condensor Shall have with Hydrophlic Coating and Corrision Resistance Black CoatedFin. All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor.All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid.All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor. The rates is inclusive all types taxes as imposed by the Government.The C.O.P of ODU should have 3.5 at 100% load.The ODU should work at temp in Range -25 to 55 Deg C. |
| 40 | Outdoor Unit |
| 41 | Supplying, Installation Testing and Commissioning Including vacumising, Gas charging of Modular type outdoor units equipped with highly efficient scroll compressors, with all Inverter Scroll type compressor(s), special acryl pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralized controller for individual control complete as per OEM specifications of Following Capacity. |
| 42 | All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid.,Multiple Bids are acceptable for Single Make also.The Authorisation Letter from OEM is Must for bidder. |
| 43 | Out Door Unit -24 HP Top Discharge |
| 44 | Supply of Ceiling Suspended type AHU. |
| 45 | 4 Way Cassette Type Unit - 1.5 TR |
| 46 | 4 Way Cassette Type Unit - 3 TR |
| 47 | 4 Way Cassette Type Unit - 4.5 TR |
| 48 | SITC OF AHU-4000 CFM , 10 TR , 6 RD |
| 49 | sitc OF AHU EEV KIT& COMM . KIT |
| 50 | Supplying of Imported fittings (Ref Net) Y-joints etc as per specifications as required complete in all respects.( for indoor) |
| 51 | Supplying of Imported fittings (Ref Net) Y-joints etc as per specifications as required complete in all respects.( for Outdoor) |
| 52 | Supplying of Cordless Remote reqd. to operate the indoor Cassette units as per specification mentioned in the bidding document and as per standard guidelines etc. as required. |
| 53 | Supplying, installation, testing and commissioning of following sizes of refrigerant copper piping work with 19/13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications duly painted with protective ultra violet paint complete as required. All piping works inside the class room shall be duly supported with MS hangers and clamps. |
| 54 | 41.3mm outer dia (insulation 19mm) |
| 55 | 34.9mm outer dia (insulation 13mm) |
| 56 | 28.6mm outer dia (insulation 13mm) |
| 57 | 22.2mm outer dia (insulation 13mm) |
| 58 | 19.1mm outer dia (insulation 19mm) |
| 59 | 15.9mm outer dia (insulation 13mm) |
| 60 | 12.7mm outer dia (insulation 13mm) |
| 61 | 9.5mm outer dia (insulation 13mm) |
| 62 | 6.25mm outer dia (insulation 13mm) |
| 63 | Supplying, installation, testing and commissioning of following sizes of rigid PVC piping complete with elbow T-joint, socket duly supported as per specifications and insulated with 6mm thick closed cell nitrile rubber insulation. |
| 64 | 25 mm |
| 65 | 32 mm |
| 66 | Supply, Installation, Testing and Commissioning of control cum transmission wiring of 2 core x1.25 sq mm copper wire in suitable PVC conduits between indoor & outdoor units to central remote controllers & for connections between indoor unit to outdoor unit |
| 67 | SITC of MS Stand for VRF Outdoor Units |
| 68 | SITC of Refrigerent Charge R 410A |
| 69 | SITC of G.I Duct |
| 70 | SITC of Duct Insulation- 9mm Thick Nitrile Rubber with Aluminium Foil. |
| 71 | SITC of Acoustic Lining- 10 mm Armasound |
| 72 | SITC of Al. Grilles |
| 73 | Electrical Panel-aviation LT PANELS:Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and inter change able modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. Fabrication :- Panel shall be made from 16 SWG CRCA sheet, conforming to IS 8623/1977-82. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work |
| 74 | 1. Electrical Load Calculation (Approx.)48 HP ≈ 36 kW • Power factor = 0.9 • Voltage = 415 V (3 Phase)Current calculation:I = \frac{P}{\sqrt{3} \times V \times PF}Approx current = 60 – 65 AmpsSo we design panel with safety margin. |
| 75 | 2. VRV Electrical Panel DesignIncomer • 100A TP MCCB • Breaking capacity: 25 kA • Adjustable thermal and magnetic protectionOutgoingDepending on number of outdoor units. Configuration: Item RatingMain Incomer MCCB 100A TPOutdoor Unit 1 40A TP MCBOutdoor Unit 2 40A TP MCBIndoor Unit Circuit 16A SP MCBControl Circuit 6A MCB4. |
| 76 | 3.Panel ComponentsPanel should include: • MCCB (100A) • Copper Busbar (100A rating) • Phase indication lamps • Digital voltmeter with selector switch • Digital ammeter with CT • MCB for indoor units • Earthing busbar • Neutral link • Cable glands • Powder coated sheet steel enclosure |
| 77 | 4. Cable For 48 HP VRV Outdoor Unit • 4 Core 25 sq.mm Aluminium cableor • 4 Core 16 sq.mm Copper cableEarthing: • 2 Nos. 8 SWG GI wire or 10 sq.mm Cu earthing6. 5.Basic Single Line Diagram (Concept)ncoming Supply (415V, 3 Phase) | 100A MCCB | Copper Busbar | ----------------------- | | |40A MCB 40A MCB 16A MCBOutdoor Outdoor IndoorUnit-1 Unit-2 Units |
| 78 | Estate Water Supply system |
| 79 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling as per analysis A 14 complete in all respects. (By Mechanically excavaton) |
| 80 | for 63 mm o/d uPVC pipe |
| 81 | Estate Sewerage System |
| 82 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. Depth not exceeding 3 m. BGL All kinds of soil except rocky |
| 83 | Depth not exeeding 3 m. BGL |
| 84 | For Ordinary Soil having gravel 40% |
| 85 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 86 | Single stocket type B |
| 87 | 160mm o/d single stocket SWR UPVC pipe lines laid complete IC TO MH |
| 88 | Sand filling under floor and in wells of bridge foundation including handling withing 100 metres |
| 89 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 90x150 cm and 120 cm deep |
| 90 | Inside size 90x150cm and 120 cm deep |
| 91 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 92 | 200mm o/d pipe |
| 93 | Strome sewer System with Recharge well |
| 94 | Providing, Laying , fixing & jointing of uPVC. Pipes & specials 6kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back filling as per analysis A 14 complete in all respects. (By Mechanically excavaton) |
| 95 | For 200mm o/d PVC pipe |
| 96 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 97 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the engineer in charge. |
| 98 | Single Road Gully chamber |
| 99 | Size 610mm x 457mm x 800mm |
| 100 | Providing, Laying , Houdiesprior approval of Engineer-in-Charge)Haudies (Size 0.45 Mtr x 0.45 Mtr.) |
| 101 | Providing, Laying , Houdiesprior approval of Engineer-in-Charge)Haudies (Size 0.90 Mtr x 0.90 Mtr.) |
| 102 | Providing, Laying, fixing & Jointing of uPVC, Pipes & specials 4kg/sqcm Type A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including cost of earth work in excavation & back fillig as per analysis A 14 complete in all respects. (By Mechanically excavation) |
| 103 | 160mm o/d uPVC pipe of 4kgf./sqcm |
| 104 | Construction of Recharge well 4.5mtr dia up to 5 mtr depth 1 No. ,installation of 200mm i/d tubewell up to 50 mtr depth complete in all respects. |
| 105 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. |
| 106 | Boring with 300mm id Housing Pipe, Upto 150 m depth BGL. |
| 107 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in- charge. |
| 108 | 200 mm nominal size dia |
| 109 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 110 | 200 mm nominal size dia. |
| 111 | Supplying & Fixing of M.S pipe bail plug suitable for 200 mm dia UPVC casing pipe having thickness of socket as 12 mm ,length 100 mm & base plate of 8 mm thick complete in all respect. |
| 112 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 113 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 114 | 200mm internal dia |
| 115 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 116 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 117 | 200mm internal dia |
| 118 | Foot Rest for Manhole.Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 119 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 120 | Cement concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type |
| 121 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 122 | Extra for specially moulded brick work in circular work such as well shafts circular sumps, pump chambers etc. in which specially moulded or cut bricks have to be used but for which no centring or supports are required upto 4.5 metre internal diametre. |
| 123 | 12.5 mm thick cement plaster 1:2 (Well Inside) (Collecting Chamber to well) |
| 124 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- |
| 125 | Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry). |
| 126 | 1st layer |
| 127 | Fourth Layer :----- Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry). |
| 128 | 2nd Layer |
| 129 | Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm (from Pathankot or approved equivalent quarry). |
| 130 | 3rd Layer |
| 131 | Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry). |
| 132 | 4th Layer |
| 133 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 134 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 135 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 136 | Providing and fixing RCC manhole covers only |
| 137 | 560mm i/d RCC man hole cover only as per ISI |
| 138 | Heavy duty |
| 139 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position Please Enable Macros to View BoQ information |