| 1 | Supply, Installation, Testing & Commissioning of Inverter Ducted/ Concealed split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 14.1 kw with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better , both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi/ Voltas/Blue Star)(Main OT) |
| 2 | Supply, Installation, Testing & Commissioning of Inverter Ducted/ Concealed split AC machine (a set of full metal body indoor and outdoor unit) having cooling capacity not less then 7.0 kw with veriable speed rotary/ scroll compressor, refrigerant gas R32/R410 or better , both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi/ Voltas/Blue Star) |
| 3 | Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku) |
| 4 | a) Discharge line 9.5mm dia minimum thickness 0.8mm with 9mm thick nitrile insulation(Make:Rajco/Royku) |
| 5 | b) Suction line 19.05 mm dia minimum thickness 0.99 mm with 9mm thick nitrile insulation(Make:Rajco/Royku) |
| 6 | Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex) |
| 7 | a) Liquid Line (3/8\\" OD with 0.6 mm thick) |
| 8 | b) Suction Line (5/8\\" OD with 0.7mm thick) |
| 9 | Supply of XLPE Insulated & unarmoured stranded Copper Conductor control cables h aving following numbers of core for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KE!/ Havells/ Gloster as approved by E.I.C] |
| 10 | a) 4 core 2.5 sq.mm communication cable |
| 11 | S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. |
| 12 | a) 25 mm dia |
| 13 | Charges for scaffolding arrangement incl. lifting for outdoor & indoor units |
| 14 | Supply and fixing flexible canvass connection for concealed split air-conditioners. |
| 15 | charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ply wood for IDU maintenance. |
| 16 | Supply and Fixing AL power Coated countintuous girll (Make-Premier) |
| 17 | Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (50 mm x 50 mm x 6 mm) for making platform for installation of outdoor unit of Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr.Structural design should be approved by E.I.C. |
| 18 | Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC. |
| 19 | Cutting iron windows and macking door there for passage for outdoor installation, fixing and provision for future maintenance purpose. Including charges of welding , masonary charges, labour charges and materials charges for sand ,cement , chipes etc. |
| 20 | Disconnect all connected copper pipe line,comounication cable and allied acessories from Outdoor and indoor unit,then taken down those unit carefully and shitting to departmental store of 6.00 number Existing 2 TR split/window AC machine and Allied works by highly skilled AC technician as per direction of EIC. |
| 21 | Rate is inclusive all taxes and cess |
| 22 | Defect Libility Period 1 year Please Enable Macros to View BoQ information |