| 1 | 1 Part I- Electrification &Providing Submersible Pumpset-( Materials used for the work shall be as per list of materials approved by the District level technical committees and attached as separate document) |
| 2 | OD31793/2026-2027:Supply, conveyance, installation, testing and commissioning of 1.5 HP , Open well Submersible motor pump set having head range 40 mtr, discharge -80 LPM, of pipe size 50 mm working suitable for single phase, 240V, 50 Hz AC supply and giving connections and trail run on full load. .( Deccan or equivalent make |
| 3 | OD31792/2026-2027:Supply and providing BCH make DOL Starter with protection against overload, single phasing, phase reversal & amp; severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1specifications suitable for 2 HP Submersible motor pump set complete duly internally connected |
| 4 | 90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 5 | OD31817/2026-2027: Supply and Providing 50 mm GI pipe (Heavy class) Cutting threading welding and with accessaries etc |
| 6 | OD31788/2026-2027:Supply conveyance and providing nylon MAXIMA LG14MMrope for hanging sub-pump set |
| 7 | OD31785/2026-2027:Supply and fixing CLAMP SET CI 50MM for erection of pump set |
| 8 | OD31789/2026-2027:Supply and fixing 50mmx 12" GI Barrel nipple |
| 9 | OD31887/2026-2027:Supply and fitting 50 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main. |
| 10 | OD31882/2026-2027:Supply and fixing 50 mm x 9" GI barrel nipple etc as required. |
| 11 | OD31784/2026-2027: Supply and providing rubber packing as required |
| 12 | OD31787/2026-2027:Supply and fitting 50 mm Non Return valve using required bolt and nut and flange etc |
| 13 | OD31873/2026-2027:Supply and fixing Full way valve brass 50MM ISI et. as required. |
| 14 | OD31877/2026-2027:Supply and providing. REDUCER GI 50MMX40MM ISI , etc as required. |
| 15 | OD31855/2026-2027:Supply and providing Cable Joint Tape etc. as required. |
| 16 | OD31856/2026-2027:Supply and providing Cotton waste etc. as required. |
| 17 | OD31857/2026-2027:Supply and providing Shellac 50 ml etc. as required. |
| 18 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 19 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 20 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 21 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 22 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 23 | OD31811/2026-2027:Supply and fixing 20mm corrugated flexible pvc conduit |
| 24 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 25 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 26 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 27 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 28 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 29 | OD31795/2026-2027:Supply and fitting 32A HRC fuse base with HRC fuse link |
| 30 | OD31894/2026-2027:Supply and providing 25x3mm brass nut and bolt etc. as required. |
| 31 | OD31786/2026-2027:Supply and fitting 32A 2 way neutral link mounted on DMC/SMC base Please Enable Macros to View BoQ information |