| 1 | DSR item No.29.1Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc.(Please refer DNIT for complete specification of item no.1) |
| 2 | 25 KVA |
| 3 | DSR 2.6 (Civil) Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and for all lift, as directed by Engineer-in-charge.i) All kind of soil. |
| 4 | DSR 2.27 (Civil) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | DSR item No. 4.1.11 (Civil) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:5:10 (1 cement: 5 finesand derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 7 | DSR 5.22(Civil) Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 8 | Thermo-mechanically treated bars of grade Fe-500D or more. |
| 9 | DSR 5.1 (Civil) Providing and laying in position specified grade of reinforced cement concret, excluding the cost of centering, shuttering, finishing and reinforcement- All work upto plinth level: |
| 10 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural source: 4 graded stone aggregate 20 mm nominal size derived from natural sources) . |
| 11 | DSR 13.1 (Civil) 12 mm cement plaster of mix: |
| 12 | 1:4 (1 cement: 4 fine sand) |
| 13 | DSR Item No. 5.9 (Civil) Centering and shuttering including strutting, propping etc. and removal of form for : |
| 14 | Foundations, footings, basis of columns, etc. for mass concrete. |
| 15 | DSR item 4.1Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastneretc as required. |
| 16 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 17 | DSR item No.5.4 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/coke and salt) as required. |
| 18 | DSR item No.5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 19 | DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | 3½ X 35 sq. mm (32mm) |
| 21 | DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 22 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 23 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 24 | 100 A,30KA,FPMCCB |
| 25 | 200 A,36KA,FPMCCB |
| 26 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only. |
| 27 | Size 35 Sq. mm 3.5 core (In pipe) |
| 28 | Size 35 Sq. mm 3.5 core (On surface) |
| 29 | Fabrication, Supplying, Installation, Testing and Commissioning of Indoor type cubicle type fully enclosed compartmentalized Electric Panel of suitable size (300mm-900mm) deep as required at site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base(Please refer DNIT for complete specification of item no.16) |
| 30 | Supply & erection MCB 3 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Legrand (DX3)/ Hager (h3)/ Schneider (Acti9)/ ABB (SB200M)/ Siemens (Betagard) make only. |
| 31 | Making of Haudi of following size for drawing of underground cable etc. constructed with bricks wall 9” thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture. |
| 32 | Size 2’x2’x2’ deep Please Enable Macros to View BoQ information |