| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within IICT Campus lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within IICT Campuslead as per direction of Engineer-in-charge. In cement mortar |
| 4 | Brick work with common burnt clay modular brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:6 (1 cement : 6 Fine sand) |
| 5 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of V class designation 7.5 in foundations and plinth Cement mortar 1:4 (1 cement : 4 Fine sand) |
| 6 | 18mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5(1 cement:5 fine sand)and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 fine sand) finished rough with sponge. |
| 7 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 fine sand) |
| 8 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Powder coated aluminium (minimum thickness of powder coating 50 micron)Make: Jindal or equivalent |
| 9 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Powder coated aluminium (minimum thickness of powder coating 50 micron) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required Powder coated aluminium (minimum thickness of powder coating 50 micron)Make: Jindal or equivalent |
| 10 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 11 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
| 12 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 13 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 14 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 15 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness.Make: Hardwyn or its equivalent |
| 16 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 17 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Including Cost of aluminium snap beading): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)Make: Saint-gobain or equivalent |
| 18 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)Make: Saint-gobain or equivalent |
| 19 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With Aluminium U beading. |
| 20 | Providing and applying birla wall care putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 21 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 22 | Wall painting with premium acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 23 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in Charge. With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles. |
| 24 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste coupling and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required as directed by the Engineer-In-Charge. |
| 25 | Size 450x300x150 mm |
| 26 | Size 600x450x200 mm |
| 27 | Providing and fixing C.P. brass stop/angle cock of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 28 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe: 32mm dia |
| 29 | Providing and fixing CP soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms |
| 30 | Providing and fixingCP towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching/chipping, refilling/finishing & testing of joints etc., complete as per direction of Engineer in Charge.Make: Ashirwad or its equivalent |
| 32 | 32 mm nominal dia Pipes |
| 33 | 25 mm nominal dia Pipes |
| 34 | 20 mm nominal dia Pipes |
| 35 | Providing and fixing brass valve with threaded one side of approved quality, High or low pressure etc., complete as directed by the Engineer-In-Charge. 25mm dia |
| 36 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.,150 mm diameter |
| 37 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe |
| 38 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 39 | Extra for depth for manholes : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 41 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent. |
| 42 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with 20mm thick 1:4 cement mortar including grouting of joints and skirting as directed by the Engineer-In-Charge.Size of Tile 600x600 mmMake: RAK, Johnson or its equivalent |
| 43 | Supplying and fixing 12.0mm thick Cement Bonded Particle Designer Board (Bison Panels 14276) Available Designs 1. Lumber 2.Quadra 3. Murk, Standard Size 8’x4’- 12mm Thickness as directed by the Engineer-In-Charge. |
| 44 | Labour charges for making holes with using core cutting of 6'' thick with upto 1'6'' long in masonry walls of upto average thickness as per site conditions, as directed by Engineer-In-Charge. |
| 45 | Providing, fixing and jointing/welding with Polypropylene material 110mm outer diameter Polypropylene pipes of approved make including Tee/bend/Y section/collars/flanges etc., It includes excavations or preparation of base for pipe lines with required chambers which neatly finishing with laying of cc cover and refilling wherever necessary with all leads and lifts complete as directed by Engineer-in-charge. Centre line of pipe line will be measured for payment. |
| 46 | Providing, fixing and jointing/welding with Polypropylene material 160mm outer diameter 6.2mm thick Polypropylene pipes of approved make including Tee/bend/Y section/collars/flanges etc., It includes excavations or preparation of base for pipe lines with required chambers which neatly finishing with laying of cc cover and refilling wherever necessary. It includes all leads and lifts complete as directed by Engineer-in-charge. Centre line of pipe line will be measured for payment. |
| 47 | Providing and applying crack seal of approved make like Dr.Fixit or its equvalent make including cutting grooves upto 25mm to existing cracks and it is apply into wall cracks as directed by the Engineer-In charge and including all leads and lifts as directed by Engineer-In-Charge. |
| 48 | Providing and fixing polyster fabric Roller blinds of approved design of touch window Product or its equivalent approved make and shade/desgin as per the manufacturers specifications and as directed by the Engineer-In-Charge. |
| 49 | Providing and fixing of 15mm dia laboratory cp swan neck tap of approved quality as per the manufacturers specifications and as directed by the Engineer-In-Charge.Make: Vijay |
| 50 | Removing and refixing of False ceiling tiles of all types including necessary screws, hardware etc., for fixing and channels wherever necessary to replace etc., complete all leads and lifts as directed by the Engeer-In-Charge. |
| 51 | Wiring in existing conduit: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ Metal angular frames/ recessed steel/ PVC conduit as required.Make: Finolex/ Havells |
| 52 | 1 x 1.5 sq. mm |
| 53 | 2 x 1.5 sq. mm |
| 54 | 3x2.5 sq.mm |
| 55 | 3x4 sq.mm |
| 56 | 5x6 sq.mm |
| 57 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular indicator switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(i) Group C |
| 58 | S/F PVC Conduit: Supplying and fixing of following sizes of PVC conduit along with accessories on Metal Angular frames, pipes with necessary weldings to fix pvc pipe/ surface/recess cutting the wall and making good the same in case of recessed conduit as required. Make: Sudhakar(i) 25mm |
| 59 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.Make: Anchor/ Legrand/ North West |
| 60 | 3 Module (100mmX75mm) |
| 61 | 6 Module (200mmX75mm) |
| 62 | 12 Module (200mmX150mm) |
| 63 | S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required. |
| 64 | 5/6 A switch |
| 65 | 15/16 A switch |
| 66 | 3 pin 5/6 A socket outlet |
| 67 | 6 pin 15/16 A socket outlet |
| 68 | S/F 'C' series MCB: Supplying and fixing of 5A to 32A rating, 240V/415 V, 10 kA, 'C' curve. Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc., as required. |
| 69 | Single pole |
| 70 | Triple pole |
| 71 | Triple pole & Neutral |
| 72 | Labelling and Lettering of Switchboard/ Power board of required font to suit the equipment with required coloured paint with elegant finishing as required by the Engineer. |
| 73 | Brush Less Direct Current (BLDC) Motor:Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)Make: Atomberg. |
| 74 | Supplying and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 75 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 76 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 77 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 78 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 79 | LED Down lighter (COB Type) (System lumen efficacy ≥105 < 120 lm/Watt ).Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following bodymaterial and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c externalconnections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector12 -15 wattMake: Philips/ Havells |
| 80 | Supply of poly carbonate 1x18 watts, 4feet, LED Tube light set, along with 1xTLED fixture, LED Tube-1no, complete with all accessories as directed by Incharge Electrical.Cat.no.TMC501P 1xTLED 20W-14# LED tube 18watts, 865, T8Make:Philips |
| 81 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED Fitting of all types, complete with all accessories and tube/lamp etc. with 2 nos. of 3 feet down rod on metal angular frames with suitable clamps and securing the light fixture tightly with checknut arrangement, including wiring the down rods with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required and as directed by Engineer incharge. |
| 82 | SITC of PCC panel of rating 320 A, 415 V, Three Phase and Neutral, 50 Hz, Indoor, Floor Mounted, Fixed type, Compartmentalised type, CRCA Sheet steel of thickness not less than 2 mm for load bearing members and 1.6 mm thick for Doors of LT panels and 2 mm for Gland plate, suitable Tinned Copper Busbar of 320 A, neutral bus bar of suitable capacity, earth bar, din bar, interconnections with adequate size of copper strip extended upto the cable alley side, powder coated painting with 7 tank process of approved color, including earthing etc., MS angle frame pedestal to suit the PCC panel and covered with duly enamyl painted G.I. sheets (screw & nut fixed) for three sides of the pedestal, IP65, Dust and Vermin proof, maximum operable height of Panel must not be more than 1.7 metre and maximum vertical height of panel must not exceed 2.5 metre, Top and Bottom provision by Gland plates for Incoming and outgoing cables etc. and making good of floor/base, the general construction shall conform to IS8623:93 with cable and anodized compartments labelling as required by the Engineer incharge and mounting of the following components as per the requirements. The drawing of PCC Panel approval has to be taken before fabrication, PCC panel on site inspection will be done during fabrication and testing by Engineer Incharge, once the final inspection and testing is done the PCC panel can be transported to site. All Outgoing MCCB's must have Thermal Magnetic release, OC & SC protection, including all MCCB accesories like Spreaders, Spacers etc.A. INCOMER:(i) 320 A, 4P, 36 kA, MCCB with Thermal-magnetic release, O/C & S/C protection - 01 No.(ii) MCCB Mounting Accessories (Spreaders, Spacers etc.) - 01 set.(iii) Digital Multi-Function Panel meter (Voltage, Current, Hz, kWhr etc.), model 4410 class1, 3PH, cat.no.: WL441010OOOO make:L&T - 01 No.(iv) CT's 250/5 A, 10/5 VA - 03 No.(v) MCB's and Fuse set for Control wiring and pilot lamp protection - 01 Set(vi) RYB, LED Pilot lamps -01 set.B. OUTGOINGS:1) 125 A, FP, MCCB - 05No. |
| 83 | Supply of 4Cx35 Sq. mm XLPE/PVC Insulated, PVC Sheathed, 1.1 kV grade, Copper Conductor FRLS, ISI marked Flexible Unarmoured Multistrand Cable. |
| 84 | Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 85 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 86 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 87 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 88 | Supplying and making end termination with PVC cable gland and copper lugs for following size of PVC insulated and PVC sheathed flexible copper conductor cable of 1.1 KV grade as required.(i) 4C X 35 sq. mm |
| 89 | Supply of 3.5C x 300 sq.mm Al. Conductor armoured XLPE Insulated, PVC sheathed 1.1kV grade cable. |
| 90 | Earthing with copper earth plate 600mmX600mmX3mm thick including brazing of 40mm dia medium class GI Pipe with all accessories, Providing two runs of 25mmx5mm Copper strip from copper plate with proper brazing upto 2.7mtrs length and providing masonry enclosure with cover plate having locking arrangement with charcoal/ coke and salt as directed by Engineer incharge.Note: A homogenous layer of charcoal and salt are to be filled upto the plate level and a homogenous layer of charcoal & salt will be filled throughout the pipe upto ground level (similar to pipe earthing). |
| 91 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess including Insulators & Green colour heat shrinkable sleeve for connections etc. as required and as directed by Engineer In-Charge. |
| 92 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer and fixing of Green colour Heat shrinkable sleeve etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) and as directed by Engineer In-Charge. |
| 93 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 300 sq. mm (70mm) |
| 94 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 95 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including all accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 40 mm dia, 2.7 metre long including wleding etc. with charcoal/ coke and salt as required.Note: A homogenous layer of charcoal and salt are to be filled upto the plate level and a homogenous layer of charcoal & salt will be filled throughout the pipe upto ground level (similar to pipe earthing). |
| 96 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer including insulators etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) and as directed by Engineer In-Charge. |
| 97 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections including insultaors etc. as required and as directed by Engineer In-Charge. |
| 98 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make: Finolex/ Havells |
| 99 | 1x6 Sq.mm |
| 100 | 1x10 Sq. mm |
| 101 | Supply and Fixing of 24 Port Non POE manageable switch. Model No. Aruba Ion 1930 24G, 4SFP+ |
| 102 | Supply and Fixing of 24 Port POE switch. Model No. Aurba Ion 1930 24G, 4SFP + 195W SW |
| 103 | Supply and Fixing of Cat 6 UTP cable 305 mtr box. |
| 104 | Supply and Fixing of Cat 6 Information outlet with face plate and back box. |
| 105 | Supply and Fixing of Cat 6 UTP patch cable of 2 meter length. |
| 106 | Supply and Fixing of Cat 6 UTP patch cable of 1 meter length. |
| 107 | Supply and Fixing of 2 inch pvc conduit. |
| 108 | Supply and Fixing of 9U Rack with accessories |
| 109 | Supply and Fixing of 24 Port fully loaded Jack panel. |
| 110 | Supply and Fixing of 1 inch pvc conduit. |
| 111 | Supply and Fixing of TP Link Omada AC1350 wireless ceiling mount Access points. |
| 112 | Service charges for laying of CAT 6 UTP cable through PVC condiut. Fixing of face plate, termination of information outlet, fixing of switch and acess points, fixing of rack, patch cables, labelling, dressing, end to end testing.Note: Please visit the site before quoting the all above item rates and site should be handed over to department with cleaning after completion of the work Please Enable Macros to View BoQ information |