| 1 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in Hard dense Soil complete all as specified.Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor |
| 2 | Excavation in trenches inany type of Hard dense soil not exc 1.5m wide and exc 1.50 mtr but not exc 3.00 mtr in depth for foundation etc and getting out in hard dense soil complete all as specified.Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor |
| 3 | Excavation in trenches in any type of Hard dense soil not exc 1.5m wide and exc 1.50 mtr but not exc 4.50 mtr in depth for foundation etc and getting out in hard dense soil complete all as specified.Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor |
| 4 | Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose/disintegrated soil or rocks complete all as specified. |
| 5 | Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed. |
| 6 | M&L for cement concrete 1:3:6 type C-2 using 40mm graded aggregates for bedding layers laid (SN8) 180(OD)/163(ID) mm internal dia DWCPE pipes after they are laid and tested complete all as specified (thickness of concrete bed 100 mm). |
| 7 | S&F DWCPE(SN8) 180(OD)/163(ID) mm dia pipes and Snap fit/ Push fit coupler with rubber ring/ gasket for joining incl testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified. |
| 8 | M&L for cement concrete 1:3:6 type C-2 using 40mm graded aggregates for bedding layers laid DWCPE(SN8) 200(OD)/175(ID) pipes after they are laid and tested complete all as specified (thickness of concrete bed 150mm). |
| 9 | S&F DWCPE(SN8) 200(OD)/175(ID) mm dia pipes and Snap fit/ Push fit coupler with rubber ring/ gasket for joining incl testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified. |
| 10 | M&L PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregates as in foundation of manholes, posts etc complete all as specified. |
| 11 | M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4 complete all as specified. |
| 12 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified. (Water proofing compound shll be measure and paid separatelly). |
| 13 | M&L for PCC 1 : 2 : 4 type B2 using 20mm graded aggregates as in surfaces channels and drains complete all as specified. |
| 14 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc complete all as specified. |
| 15 | M&L Mild steel Round/TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 16 | M&L Providing pre cast RCC type B1 20mm graded aggregate 1:2:4 in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces |
| 17 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc Complete all as specified. |
| 18 | Demolition and breaking up drain pipes of 100mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 19 | Demolition and breaking up drain pipes of 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 20 | Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1 : 2 : 4 type B1 finished smooth and reforming benching as required for 100 mm dia pipes complete all as specified. |
| 21 | M&L RCC(NOMINAL MIX) M-20 (Type B1 1:2:4 Using 20mm graded stone aggregate) as in Slabs supported on walls,man hole cover, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like. |
| 22 | M&L for Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 23 | M&L for Formwork to soffits of Curved suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 24 | Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1 : 2 : 4 type B1 finished smooth and reforming benching as required for 150 mm dia pipes complete all as specified. |
| 25 | Schedule of Credit Please Enable Macros to View BoQ information |