| 1 | Schedule 'A' |
| 2 | Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 100 HP / 120 HPNote : (i) The rate considered is inclusive of T&P required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site. |
| 3 | Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 60HP / 50 HPNote : (i) The rate considered is inclusive of T&P required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site. |
| 4 | Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 20 HPNote : (i) The rate considered is inclusive of T&P required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site. |
| 5 | Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 15 HPNote : (i) The rate considered is inclusive of T&P required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site. |
| 6 | Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 7.5 HPNote : (i) The rate considered is inclusive of T&P required for carrying out the repairs.(ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site. |
| 7 | Supply only the following spares for pump sets of capacity 120 / 100 HP(Note: Make of spares shall be of the original make of the pump) Make :- Kirloskar/ CG (6.01) Pump Shaft |
| 8 | (6.02) Bronze impeller 1st stage |
| 9 | (6.03) Wear ring Bronze |
| 10 | (6.04) Inter stage ring Bronze |
| 11 | (6.05) Water deflector rubber |
| 12 | (6.06 ) Bearing cartridge cast iron drive end |
| 13 | (6.07 ) Bearing cartridge cast iron non drive end |
| 14 | (6.08) Shaft sleeve bronze drive end |
| 15 | (6.9) Shaft sleeve bronze non drive end |
| 16 | (6.10) Spacer sleeve drive end |
| 17 | (6.11) Spacer sleeve non drive end |
| 18 | (6.12) Key for impeller and sleeve |
| 19 | (6.13) Bearing lock nut |
| 20 | (6.14) Stuffing box bush |
| 21 | (6.15) O' ring for shaft sleeve |
| 22 | (6.16) Cast iron gland (Set of 2 halves) |
| 23 | (6.17) Eye bolt for gland with nut and washer |
| 24 | (6.18) Gland guide bush large |
| 25 | (6.19) Gland guide bush small |
| 26 | (6.20) Center link bush |
| 27 | (6.21)Check nut |
| 28 | (6.22) Shaft Pulley |
| 29 | Supply only the following spares for pump sets of capacity 60 / 50 HP(Note: Make of spares shall be of the original make of the pump) Make :- Kirloskar/ CG (28.01) Pump Shaft |
| 30 | (28.02) Bronze impeller 1st stage |
| 31 | (28.03) Wear ring Bronze |
| 32 | (28.04) Inter stage ring Bronze |
| 33 | (28.05) Water deflector rubber |
| 34 | (28.06 ) Bearing cartridge cast iron drive end |
| 35 | (28.07 ) Bearing cartridge cast iron non drive end |
| 36 | (28.08) Shaft sleeve bronze drive end |
| 37 | (28.9) Shaft sleeve bronze non drive end |
| 38 | (28.10) Spacer sleeve drive end |
| 39 | (28.11) Spacer sleeve non drive end |
| 40 | (28.12) Key for impeller and sleeve |
| 41 | (28.13) Bearing lock nut |
| 42 | (28.14) Stuffing box bush |
| 43 | (28.15) O' ring for shaft sleeve |
| 44 | (28.16) Cast iron gland (Set of 2 halves) |
| 45 | (28.17) Eye bolt for gland with nut and washer |
| 46 | (28.18) Gland guide bush large |
| 47 | (28.19) Gland guide bush small |
| 48 | (28.20) Center link bush |
| 49 | (28.21)Check nut |
| 50 | (28.22) Shaft Pulley |
| 51 | Supply only the following spares for pump sets of capacity 20 / 15 HP (Note: Make of spares shall be of the original make of the pump) Make :- Kirloskar/ CG (50.01) Pump Shaft |
| 52 | (50.02) Impeller |
| 53 | (50.03) Casing wear ring |
| 54 | (50.04) Casing cover |
| 55 | (50.05) Lantern ring |
| 56 | (50.06) Gland collar |
| 57 | (50.07) Liquid deflector |
| 58 | (50.08) Bearing housing |
| 59 | (50.09) Support foot |
| 60 | (50.10) Bearing cover |
| 61 | (50.11) Shaft sleeve |
| 62 | (50.12) Key for impeller |
| 63 | (50.13) Key for coupling |
| 64 | (50.14) Impeller nut |
| 65 | (50.15) Washer for impeller |
| 66 | (50.16) Gland packing |
| 67 | (50.17) Grease Nipple |
| 68 | (50.18) Gasket for casing cover |
| 69 | (50.19) Gasket for shaft sleeve and shaft |
| 70 | (50.20) O' ring for sleeves & impeller |
| 71 | (50.21) Tie rod |
| 72 | Supply only the following spares for pump sets of capacity 7.5 HP (Note: Make of spares shall be of the original make of the pump) Make :- Kirloskar/ CG (71.01) Pump Shaft |
| 73 | (71.02) Impeller |
| 74 | (71.03) Rotor |
| 75 | (71.04) Spacer |
| 76 | (71.05) Gland Collar |
| 77 | (71.06) Lantern ring |
| 78 | (71.07) Water deflector |
| 79 | (71.08) Shaft Sleeve |
| 80 | (71.09) Key for impeller |
| 81 | (71.10) Gland packing |
| 82 | (71.11) Priming plug |
| 83 | (71.12) Washer for impeller nut |
| 84 | (71.13) Gasket for casing cover |
| 85 | (71.14) Split cotter Pin |
| 86 | Supply only Ball bearing / Roller bearing for the following pumpsets: Pump Capacity 120HP / 100HP(Make: SKF/FAG/Rolon/NRB) |
| 87 | Supply only Ball bearing / Roller bearing for the following pumpsets: Pump Capacity 60HP / 50HP(Make: SKF/FAG/Rolon/NRB) |
| 88 | Supply only Ball bearing / Roller bearing for the following pumpsets: Pump Capacity 20HP(Make: SKF/FAG/Rolon/NRB) |
| 89 | Supply only Ball bearing / Roller bearing for the following pumpsets: Pump Capacity 15HP(Make: SKF/FAG/Rolon/NRB) |
| 90 | Supply only Ball bearing / Roller bearing for the following pumpsets: Pump Capacity 7.5HP(Make: SKF/FAG/Rolon/NRB) |
| 91 | Supply only drive end bearing for the following pumpsets: Pump Capacity 120HP / 100HP(Make: SKF/FAG/Rolon/NRB) |
| 92 | Supply only drive end bearing for the following pumpsets: Pump Capacity 60HP / 50HP(Make: SKF/FAG/Rolon/NRB) |
| 93 | Supply only drive end bearing for the following pumpsets: Pump Capacity 20HP(Make: SKF/FAG/Rolon/NRB) |
| 94 | Supply only drive end bearing for the following pumpsets: Pump Capacity 15HP(Make: SKF/FAG/Rolon/NRB) |
| 95 | Supply only drive end bearing for the following pumpsets: Pump Capacity 7.5HP(Make: SKF/FAG/Rolon/NRB) |
| 96 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 100HP / 120HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 97 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 60HP / 50HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 98 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 20HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 99 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 15HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 100 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 7.5HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 101 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 5HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 102 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 3HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 103 | Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 1HP Note : (i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back. (v) The cost of spares for pump considered separately under appropriate items here-in-after. |
| 104 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 3 phase 100HP / 120HP capacity |
| 105 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 3 phase 60HP / 50 HP capacity |
| 106 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 3 phase 20 HP capacity |
| 107 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 15 HP capacity |
| 108 | Material & Labour for rewinding of electric Pump starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric open well submersible pump, 15HP / 20 HP capacity |
| 109 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Submersible Electric motor, 7.5 HP capacity |
| 110 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 7.5/5 HP capacity |
| 111 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor, 3 HP capacity |
| 112 | Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelled copper winding wire complete including varnishing and heating all as specified and directed of the following sizes: (a) Electric motor of pressure pump, 1 HP capacity |
| 113 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 3 phase 120HP / 100 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 114 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 3 phase 60HP / 50 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 115 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 3 phase 20 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 116 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 15 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 117 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric Submersible motor, 7.5 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 118 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 5 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 119 | Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor. Electric motor, 3 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 120 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric motor, 3 phase 120HP / 100 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 121 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric motor, 3 phase 50HP / 60 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 122 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric motor, 3 phase 20HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 123 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric motor, 3 phase 15HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 124 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric Submersible motor, 7.5 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 125 | Supply only ball bearing/ roller bearing ( Drive end bearing) for the following electric motor. Electric motor, 3 phase 5 HP capacity (Make: SKF/FAG/Rolon/NRB) |
| 126 | S&F in repair rubber star coupling high speed suitable for centrifugal pumpset (5HP to 10HP) |
| 127 | S&F in repair rubber star coupling high speed suitable for centrifugal pumpset (15HP to 20HP) |
| 128 | S&F in repair rubber star coupling high speed suitable for centrifugal pumpset (30HP) |
| 129 | S&F in repair rubber star coupling high speed suitable for centrifugal pumpset (50HP / 60HP) |
| 130 | S&F in repair rubber star coupling high speed suitable for centrifugal pumpset (100HP / 120HP) |
| 131 | S&F in repair rubber tyre coupling high speed suitable for centrifugal pumpset (upto 50HP / 60HP) |
| 132 | S&F in repair rubber tyre coupling high speed suitable for centrifugal pumpset (upto 100HP / 120HP) |
| 133 | S&F gallon dori of any size suitable for centrifugal pumpset / Sluice valve complete all as specified and directed. |
| 134 | M & L for painting of pump set of capacity 15HP to 120HP, including connected starter inside pump house with two coats of anti corrosive synthetic enamel paint over a coat of red oxide primer as per existing colour after preparation of old painted surfaces complete all as specified and directed. |
| 135 | Testing of water for potability test by chemical and bacteriological from any Govt. laboratory such as PH value, Total dissolved solids, hardness as CaCOᶟ, Calcium, Magnesium, Chlorides, Sulphates, Nitrate, Alkalinity, Iron, Turbidity NTU, Mineral oil, Colur hazen units, Taste, Odour, Residual free Chlorine, Total Coliform per 100ml (Microbiologocal test) & E Coli per 100ml (Microbiological test) complete and report to be submitted to the department in triplicate in hard bound copy complete all as specified and as directed. |
| 136 | S&F in replacement damaged/burnt 25 sqmm 3 core copper cable complete all as specified and directed by Engr-in-Charge. |
| 137 | Supply Only Sodium Hypochloride complete all as specified directed |
| 138 | Supply Only Alum (crystal type) complete all as specified directed |
| 139 | Supply and fix in replacement relay for pressure pump of any size and capacity complete all as specified directed. |
| 140 | S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 100 HP/120 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves |
| 141 | S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 60/50 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves |
| 142 | S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 20/15 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves |
| 143 | S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 10 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves |
| 144 | S&F in repair DOL starter in sheet enclosure suitable for 7.5 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves |
| 145 | S&F in repair 3 pole Power Contractors -Type MNX, Confirms to IS /IEC 60947-4-1, Click fit type construction up to 40Amp, MNX 140/150 Complete all as specified and directed. |
| 146 | S&F in repair for 3 pole Power Contractors -Type MNX , Confirms to IS /IEC 60947-4-1, Click fit type construction up to 40Amp, MNX 110/115 Complete all as specified and directed. |
| 147 | S&F in repairs cast iron flanged type foot valve 200mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainer complete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader) |
| 148 | S&F in repairs cast iron flanged type foot valve 150mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainer complete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader) |
| 149 | S&F in repairs cast iron flanged type foot valve 100mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainer complete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader) |
| 150 | S&F in repairs cast iron flanged type foot valve 80mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainer complete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader) |
| 151 | S&F in repairs cast iron flanged type foot valve 50mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainer complete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader) |
| 152 | S&F LED flood light 70 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plate connection complete all as specified and directed. |
| 153 | S&f Rubber gasket of 6 mm thich complete all as specified and as directed. |
| 154 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 155 | Supply only Inorganic polymerised liquid primary coagulant for drinking water treatment with the following specifications:Appearance: Clear to slight hazy liquidOdour: OdourlessSpecific gravity: 1.3300 – 1.3500pH (30% w/v): 4.00 – 4.40Melting / Freezing point: -7 ºCEvaporation rate: 50 – 75% (water)Viscosity: < 50 cpsOral LD50: 5000 mg/kg (Rat) Please Enable Macros to View BoQ information |