| 1 | Earthwork in excavation in foundation with lead & lift i/c all cost of labour & T&P etc. for proper completion of work. |
| 2 | P/Fixing Centering & Shuttering for Cement concrete work including cost of materials, labour & T&P etc. required for proper completion of work. |
| 3 | R.C.C. work with cement approved coarse sand 2cm gauge approved stone ballast in the proportion of 1:1.5:3 for the R.C.C columns excluding supply of reinforcement and its bending |
| 4 | Class Ist M-150 Brick work in1:4 cement and caurse sand mortar in foundation and plinth including supply of all material labour and T&P etc required for proper completion of work. |
| 5 | Class Ist M-150 Brick work in1:4 cement and caurse sand mortar in superstructure above plinth level upto floor V level including supply of all material labour and T&P etc required for proper completion of work. |
| 6 | P/Laying 12 MM thick Cement plaster with 1:4 Cement mortor (Coarse sand FM 2.6) i/c all cost of materials, labour & T&P etc. for proper completion of work. |
| 7 | 15 mm thick plaster with cement mortar in proportion of 1:4 cement & fine sand of 1.25 F.M. on rough side |
| 8 | P/Laying Cement concrete M-15, A-20, Coarse sand (FM 2.25) (1:2:4) with mechnical mixing including all cost of materials, labour & T&P etc. required for proper completion of work in Flooring |
| 9 | Construction of granular sub-base by providing coarse graded material of approved quarry, spreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achive the desierd density, complete as per clause 401. |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in grantrys,frames,ladder etc |
| 11 | P/Fixing 50x50x4 mm M.S. Pipe For ,Horizontal and Roof Rafter at site in proper alignment including cost of all material, labour and T&P etc. required for proper comp. of work. |
| 12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of comugation as approved by Engineer-in-charge) 0.50 mm (+0.05%) total coated thickness with zinc coating 120 grams per som as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /selt tappings of size (5.5x 55 mm) with EPDM seal, complete upto any pen in honze vertical or curved surfares. excluding the cost of purlins, afters and trus.. including cutting to size and shape wherever required |
| 13 | One priming coat&one coat oil distemper on new work inc. supply of all material,labour and T&P etc. req for completion of the work as this item but for every coat after the first coat |
| 14 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or mere coats applied 1.43 Il/10 sqm over and Including priming coal of exterior primer applied 2.20 kg/ 10 sqm) (apex Ultima, weather coat All quard) asian, berger. |
| 15 | Supplying and Filling in Plinth with Sand under Floor, i/c watering,ramming,consolidating and dressing complete |
| 16 | P/Laying of Interlocking Concrete block pavement having thickness 80 mm (exclusive G.S.B) |
| 17 | Supply and fixing rolling shutters of approved make,made of required size M.S laths, interlocked together through their entire length and jointed together at the end by end locks inc. all supply T&P |
| 18 | Providing and applying while cemenl based puly of average thickness 1 mm, approved brand and manulacturer, over Ihe plas ered wall surface lo prepare of tha surfaco oven and smooth complete |
| 19 | Providing and laying vitrified floor tiles. In different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement [email protected] kg/ sqm Including grouting the joints with white cement and matching pigments etc., complete size of tiles 6000x600mm |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, Including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charga. (Note: Cement content considered in this item is 330 kg/cum. Excess less cement used as per desigh mix is payable/recoverable separately). all works above plinth level |
| 21 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge (100 mm ) |
| 22 | Steel reinforcement for R.C.C. work including straightening. cutting; bending, placing In position and binding all complete |
| 23 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Please Enable Macros to View BoQ information |