| 1 | Dismantling of old existing pole upto 10/12 mtr height alongwith brackets and fittings for new installed GI octagonal pole with using proper engineering & safety tools, gas cutter, Crane/ tower wagon etc. as required at site as decided by Engineer in Charge i/c removing of pole foundation and making the site finished, neat and clean surface / road & make good etc as required completed at site |
| 2 | Dismantling of existing street light foundation of with the help of suitable equipments and as decided by Engineer in Charge etc as reqd complete at site. |
| 3 | Supplying, installation, testing and commissioning of 12.5 Meter height High Mast with nominal size base dia 360mm and top 150mm in polygonal structure, with comprising of winch for raising /lowering, motor push button, aluminum pulleys, head frame with latching system to enhance the safety, lightning protection finial & buffers, resting on the foundation bolts duly provided with stiffeners, double locking arrangement for the door and pole installed on the existing foundation complete as per specifications attached i/c supply and fixing the following accessories.a) Hot dipped galvanized internally & externally, suitable for wind velocity as per IS 875 part. sheet thickness 3 mm, high mast having octagonal structures in two sections with flanges provided with strengthening gussets between bolt holes for stiffening complete with raising/lowering mechanism, double drum winch, motor push button station, pulleys, head frame, lightening protection finial and buffers, The sections shall be stress/slip fitted without any circumferential weld in between. - 1 No.b) Galvanized Lantern carriage with 6 nos. arms secured tightly with suitable arrangement for fixing of upto 6 Nos. luminaires & other accessories complete etc. as required - 1 No.c) Set of stainless steel hoisting ropes of 6 mm dia. - 1 Setd) 0.5 HP Motor suitable to operate on 230V/415V, 50Hz, 960 RPM detachable type for lowering and lifting mechanism - 1 No.e) Supplying and drawing multicore, copper conductor flexible power trailing cables of appropriate rating for energizing the luminaries complete as per specifications. f) Supply & Fixing of LED aviation light - 1 No.g) Supplying & fixing of foundation bolts manufacturere from special steel along with nuts, washer, anchor plate & tamplates etc. nut shall be welded to the bolt. |
| 4 | Providing and laying in position M-25 (1:1:2) reinforced cement concrete foundation of size 900 mm (L) x 900 mm (W) and 2000 mm (D) at Top & at Bottom thickness mat with reinforce and iron bars below 1200 mm (L) x 1200 mm (W) and 200 mm (D) i/c excavation of earth, providing cutting, bending and placing in position, reinforcement TMT bars of 12 mm dia - 2500 mm long (approx) - 20 Nos. and reinforcement ring of cold twisted bar of 8 mm dia - 3300 mm (approx) - 9 Nos., (with 150 mm spacing), for top and 10 mm dia - 2500 mm long (approx) - 32 Nos. for bottom as required with positioning of foundation bolts and providing 90 mm (O.D.) DWC, HDPE pipe for cable entry and exit as reqd. at the bottom most part of foundation, 1500 x 1500 x 200 mm PCC (1:4:8) has to be made apart from above RCC, i/c removing of Malba, Debri etc from site and site will be neat and clean after complete. |
| 5 | Supplying, Installation, testing and commissioning of 12 m height Fancy street light pole double arm bracket made of fully GI sheet 6 mm thickness steel sheet, IP-65 Fully weather proof, finish with antique colour pole paint two and more coat i.c 1500/1800 mm long fancy double arm bracket, window height 1.5 m and pole having base plate size 300 x 300 x 20 mm thick. Including connection of 3 x 4 Sq.mm Aluminium wire for supply of fitting, duly wired up to connector complete etc as reqd. The bottom column should have an integral inbuilt looping box with cover of the same. The pole shall be installed on foundation including supply and fixing of anchor plate, foundation bolts, making foundation, excavation of earth, cutting, bending, placing DWC Pipe and refilling & removing of waste malba debris from site and transport to MCD dumping yard etc as required. |
| 6 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 750 mm.(L) X 750 mm. wide and 1800 mm. deep i/c excavation of earth, providing hard cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia- 1960mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2800mm (approx) - 10nos. (with 150mm spacing) as required with positioning of foundation bolts (as per item below) and providing 90 mm. (O.D) DWC, HDPE Pipe for cable entry & exit as required. (for 12 m pole) |
| 7 | Supply and drawing following sizes of PVC insulated Aluminum conductor unarmoured multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd. a) 3 core 4 sq.mm |
| 8 | Supplying and Laying of XLPE, Aluminum armored conductor cable in the existing pipe as reqd i/c termination of cable with suitable size thimble at both end etc as required complete at site.a) 4 X 25 sq.mm |
| 9 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 11 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 13 | Cutting of R.C.C. / Bitumen Road etc for laying DWC Pipe upto depth of 30 cm work, cutting by machine including making good as same as with RMC M- 25 grade earlier i/c taking out and laying existing CC intelocking paver block of any design/shape from footpath / central verge without broken the paver block and removing and laying with the safety and disposal of unserviceable materials (Malba, debris etc) to suitable area at the same day and site will be neat and clean as per direction of Engineer - in- charge etc as required complete at site & no extra payment for any other item shall be paid by department. |
| 14 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy>135 lm/Watt)Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 200 watt |
| 15 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 250 watt |
| 16 | Supplying and fixing hot press moulded SMC box outerdoor type / street light feeder pillar type double hinged door distribution box of size 700 mm x 480 mm x 210 mm size made out of sheet moulding compound dust and weather proof with front openable hinged type cover with canopy & locking arrangement i/c supplying and fixing following accessories and mountings inside the cubical panel i/c connection, inter-connection, 4 nos aluminium busbar connection with main MCCB to contactor distribution outgoing interlock connection with bus bar alongwith aluminum thimbles, gland, earthing with two nos. earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd. providing & fixing of following accesories etc including MS sheet fixed on MS angle iron frame work of size 50 mm X 50 mm X 6 mm (NS) with 90 cm long legs duly provided with locking arrangement grouted in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 20 mm) , connections, testing and commissioning on the central verge and footpath etc as reqd. |
| 17 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 250 A,36KA,FPMCCB, Incoming |
| 18 | b) 125 A, 16 KA,TPMCCB, Outgoing |
| 19 | c) 110 Amp Contractor, TP |
| 20 | d) Digital Timer |
| 21 | e) Digital Ammpere 0-100 Amp 96 sqmm flush type with selector switch & 100/5 Amp ratio CTs and Digital Voltmeter 0-500 volt 96 sqmm flush type with selector switch |
| 22 | f) LED Indication lamps (RYB) with 6 Amp. SPMCB - 1 Set (1 set of 3 nos.) |
| 23 | Fabricating, supplying and fixing of wire mesh protection frame work fabricating with 40 x 40 x 6 mm thick angle iron/Tee iron having intermediate members of size 25mm x 6 mm flat strip welded at 30 cm in each sections & duly welded with hard drawn wire fabric mesh of size 25 mm X 75 mm (GI wire should be 6SWG) having weight not less than 7.5 Kg/Sqmtr. and making main door gate provided with two nos. sliding bolt with 02 nos. godown inter locks with operating hadle welded from inside of the door i/c providing and fixing of four no. legs of same angle size of 90 cm length duly grouted in foundation (30 x 30 x 45) cm (deep) in 1:2:3 cement concrete & painting with one coat of red oxide & two coat of super synthetic luminous paint of approved colour and quality etc. complete as complete as reqd. {Area of hard drawn wire fabric with angle (Except legs) shall be measured for payment} |
| 24 | Painting of PWD logo and numbering on existing street light pole by cleaning the pole with Diesel and old Dhoti to make the surface good for painting of size 24 cm x 24 cm and pole numbering on exisiting octagonal pole at different roads fixed on centre verge/ footpath. Painting the pole with automotive paint of yellow colour size 24 cm x 24 cm. Making the border numbering the pole in block colour with yellow base i/c numbering of poles etc as required at site Please Enable Macros to View BoQ information |