| 1 | DESCRIPTION OF ITEMS |
| 2 | Demolition for Brickwork or stone/ boulder masonry/ pcc block walling built in Cement Mortar complete all as specified and directed. |
| 3 | M&L for brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) including complete all as specified |
| 4 | M & L cement concrete type D-2 1:4:8 (40mm graded stone aggregate) in foundation filling and mass concrete complete incl demolition all as specified and directed . |
| 5 | M & L for walling of random rubble, uncoursed well bounded, bedded and solidly hearted, built in Cement Mortar 1:6 and complete all as specified and directed. |
| 6 | M & L for walling (Except stone) of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6 and incl removal of debris outside MOD land complete all as specified and directed. |
| 7 | M & L for walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed. |
| 8 | M & L walling (Except stone) of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed. |
| 9 | Hand packing (any thickness) at back of walls with broken stone or boulders and raising (or lowering) to the required level complete all as specified and directed. |
| 10 | M & L for providing cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate, as in coping ,(50 mm thick ) bed blocks including necessary form work and incl demolition complete all as specified and directed |
| 11 | M & L for providing precast cement concrete bonders (for stone walling) type B1 (1:2:4) using 20 mm graded stone aggregate, set in cm 1:6 complete all as specified and directed. |
| 12 | M&L for raised pointing to randam polygonal rubble, uncoursed or brought upto courses in Cement mortar (1:4) complete all as specified and directed. |
| 13 | Raking out joints/pointing built in cement mortar to random rubble or polygonal rubble uncoursed or brought up to courses, washing the joints and removing rubbish off the premises complete. |
| 14 | S&F in repair 75mm bore PVC(SWR) pipes single socketed for weep holes , in any length with rubber ring joints,as in weep holes complete all as specified and directed. |
| 15 | M & L for precast cement concrete Block Masonary with solid blocks type C1 1:3:6 20mm graded stone aggregate exc 10cm in width and setting in CM 1:6 complete work all as specified and directed . |
| 16 | M & L for precast cement concrete Block Masonary (except block) and setting in CM 1:6 complete all as specified and directed . |
| 17 | M & L cement concrete type C2 1:3:6 (40mm graded stone aggregate) in surface channels and drain complete all as specified incl demolition and directed . |
| 18 | Taking down cement plaster on brick walls incl. raking out joints, hacking for key, scrubbing down with water etc. |
| 19 | M & L for rendering 15 mm thick on brick work or concrete surfaces in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified & directed. |
| 20 | M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , as per manufactures instructions etc complete all as specified and as directed. |
| 21 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified. |
| 22 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed. |
| 23 | M&L for Providing cement concrete type D-2, 1:4:8 ( using 40mm graded aggregate) as in foundation, filling and mass concrete |
| 24 | M&L for mild steel work as in posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary bolting or riveting and spot welding etc and similar work conforming to Fe-290 Gde E-165 |
| 25 | S&F Galvanised, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured) |
| 26 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n. exc 5cm long , diameter of neck 5 to 10mm |
| 27 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 28 | Supply only chain link fencing mild steel galvanised fencing any size and type (size of mesh and dia of wire as directed by Engg-in-charge) all as specified. |
| 29 | Dismantling fencing wire mesh, any type complete all as specified. |
| 30 | Fixing only chain link fencing of any type fixed to RCC / steel post with mild steel flat & nut bolt etc. |
| 31 | S&F Mild steel round bars 10mm dia and over as in strengthning bars for chain link fencing conforming to Fe-290 Gde E-165 |
| 32 | M&L for preparation of new steel surfaces of any description over 10cm width or girth, not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete. |
| 33 | M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth, not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete. |
| 34 | Removal of surplus soil to a distance exc 50m and depositing where directed at level n exc 1.5m above the starting point complete |
| 35 | Dismantling floor, hearth or wall tiling ,stone including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 36 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 37 | M & L for 75mm thick PCC 1:2:4, type B-2 using 40mm graded stone aggregate, as in pavings/hard standing/path etc finished uneven and rough without using extra cement complete all as specified & directed. |
| 38 | M&L for 25 mm thick type PCC, type B-1 1:2:4 using (20 mm graded agg) as in sub base to flooring complete all as specified & directed. . |
| 39 | S & F Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 15mm screed bed in CM 1:6 and incl demolition PCC./tile complete all as specefied |
| 40 | M& L for providing Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade/cobble stone with grey cement and no pigment of approved design and pattern complete all as specified and directed |
| 41 | Refixing of old interlocking paver blocks in approved pattern incl removing from it original position and transportation complete all as specified and directed. |
| 42 | M&L for spreading and levelling in layers n exc. 25 cm thick sand cushioning laid dry to the profile under Interlocking paver block complete all as specified and as directed. |
| 43 | M & L for non skid tiles, exterior grade, pattern of size 300x300mm, 8-10mm thick set and jointed in neat cement slurry and pointed in white/ coloured cement to match the shade as in floor over and including 15mm thick cement screed bed in CM 1:4 and dismantling of existing tiles complete all as specified and as directed. |
| 44 | M & L for precast concrete Kerb Stones factory made as in repairs of type B1, 1 : 2 : 4 (20mm graded stone aggregate) 10 to 15 cm thick and and setting in CM 1 : 6 including applying two coat of exterior emulsion paint 1st quality with one coat of putty complete and taking out existing broken stone with necessary excavation etc complete all as specified and directed. |
| 45 | Cleaning of blockage of weep holes of any type or any size in retaining walls by way of rodding and removal / clearing of mud, vegetation growth with rodding up to extreme end and making good the shape and size of weep hole with cement mortar in CM 1:4 complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |