| 1 | fo|qr forj.k [k.M eksnhuxj ds vUrxZr 11 ds0oh0 ykbZu dk lqn` |
| 2 | SAFE CARRIAGE OF S.T./PCC POLE FROM STORE CENTER TO SITE STORE WITH LOADING & UNLOADING AT BOTH ENDS RESPECTIVELY DISTANCE WITHIN- 0 TO 50 KMS. |
| 3 | PCC POLES 11 MTR. LONG |
| 4 | PCC POLES 8.5 MTR. LONG |
| 5 | LOADING, SAFE CARRIAGE & UNLOADING OF HEAVY STOCK MATERIAL V TYPE, DISC INSULATOR, PIN INSULATOR ETC. FROM STORE CENTER TO SITE STORE WITH PROPER STACKING OF MATERIAL, DISTANCE WITHIN-50 KMS. |
| 6 | LOADING, SAFE CARRIAGE & UNLOADING OF LT/HT CABLE, VCB & CONTROL PANAL TF ETC FROM STORE CENTER TO SITE STORE WITH PROPER STACKING OF MATERIAL, DISTANCE WITHIN-50KMS. |
| 7 | 11 KV XLPE CABLE OF 3X185 SQ.MM. |
| 8 | 11 KV XLPE CABLE OF 3X120 SQ.MM. |
| 9 | LT XLPE 3.5*240 SQ. MM. |
| 10 | ACSR DOG CONDUCTOR |
| 11 | ACSR REBBIT CONDUCTOR |
| 12 | ACSR WEASEL CONDUCTOR |
| 13 | LT ABC 3*120 SQ. MM. |
| 14 | LT ABC 3*95 SQ. MM. |
| 15 | LT ABC 3*50 SQ. MM. |
| 16 | LT LEAD 1*16 SQ. MM. |
| 17 | ERECTION OF SINGLE POLE ST/PCC POLE 11/ 33 KV FITTINGS AS PER RESPO DRAWING TOP CHANNAL, DROPPER CHANNAL, X BRACING SET, DISC INSULATOR, PIN INSULATOR, GUARDING ANGLE F BRACKET AND ETC AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 18 | PCC POLES 11 MTR. LONG |
| 19 | PCC POLES 8.5 MTR. LONG |
| 20 | ERECTION OF DOUBLE POLE / SACTION POLE OF 11/33 KV FITTINGS AS PER RESPO DRAWING TOP CHANNAL, DROPPER CHANNAL, X BRACING SET, DISC INSULATOR, PIN INSULATOR, GUARDING ANGLE F BRACKET AND ETC AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK. |
| 21 | PCC POLES 11 MTR. LONG |
| 22 | PCC POLES 8.5 MTR. LONG |
| 23 | EXCAVATION OF FOR EACH AND GROUTING OF SINGLE POLE AS PER RESPO DRAWING AND AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE PAD ETC. AS PER ACTUAL SITE REQUIREMENT |
| 24 | PCC POLES 11 MTR. LONG |
| 25 | PCC POLES 8.5 MTR. LONG |
| 26 | EXCAVATION OF FOR EACH AND GROUTING OF DOUBLE POLE/SACTION POLE AS PER RESPO DRAWING AND AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE PAD ETC. AS PER ACTUAL SITE REQUIREMENT |
| 27 | PCC POLES 11 MTR. LONG |
| 28 | PCC POLES 8.5 MTR. LONG |
| 29 | Plinth Of Pole/Kiking Of Pole Up Nuturel Ground Level With Material Sand, Brick Etc. Provide By The Contractor Requried For Proper Completion Of Work AS PER RESSPO MANUALS. |
| 30 | LOADING, SAFE CARRIAGE & UNLOADING OF HEAVY STOCK MATERIAL V TYPE, DISC INSULATOR, PIN INSULATOR ETC. FROM STORE CENTER TO SITE STORE WITH PROPER STACKING OF MATERIAL FROM JE STORE TO PIT SITE. |
| 31 | LOADING, SAFE CARRIAGE & UNLOADING OF LT/HT CABLE, VCB & CONTROL PANAL, CONDUCTOR TF ETC FROM JE STORE TO PIT SITE. |
| 32 | 11 KV XLPE CABLE OF 3X185 SQ.MM. |
| 33 | 11 KV XLPE CABLE OF 3X120 SQ.MM. |
| 34 | LT XLPE 3.5*240 SQ. MM. |
| 35 | ACSR DOG CONDUCTOR |
| 36 | ACSR REBBIT CONDUCTOR |
| 37 | ACSR WEASEL CONDUCTOR |
| 38 | LT ABC 3*120 SQ. MM. |
| 39 | LT ABC 3*95 SQ. MM. |
| 40 | LT ABC 3*50 SQ. MM. |
| 41 | LT LEAD 1*16 SQ. MM. |
| 42 | FIXING OF 11 KV STAY SET INCLUDING NOZELLING ETC. AS PER RESPO MANUAL AND ALSO INCLUDING THE COST OF ALL GROUTING MATERIAL, LABOUR, T&P ETC REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 43 | GROUTING OF 11 KV STAY SET INCLUDING NOZELLING ETC. AS PER RESPO MANUAL AND ALSO INCLUDING THE COST OF ALL THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE ETC. AS PER ACTUAL SITE REQUIREMENT , LABOUR, T&P ETC REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 44 | U/G CABLE WORK OF 11 KV LINE DETAIL ARE BLOW |
| 45 | LAYING AND PULLING OF 11 KV XLPE CABLE OFF SIZE THROUG HDPE PIPE |
| 46 | DRILLING OF TWO PARALLEL BORES BY TRENCH LESS METHOD BY HORIZANTAL BORING BY HDD MACHINE AT RESPO GROUND LEVEL |
| 47 | LAYING & FIXING OF HDPE PIPE FOR 11 KV CABLE OFF SIZE |
| 48 | PROVIDING & FIXING AND INTERCONNECTING 6 MTR. LONG PIECES OF HDPE PIPE SHOCKET. |
| 49 | DIGGING OF PITS OF SIZE 4 MTR X 4 MTR X 1.5 MTR. FOR CABLE LOOP |
| 50 | RESTORATION OF PIT AFTER LAYING OF CABLE LOOP |
| 51 | RESTORATION OF KACHA ROAD AFTER LAYING OF CABLE. |
| 52 | RESTORATION OF PAKKA ROAD AFTER LAYING OF CABLE. |
| 53 | Fixing of Garding angle of 11 Kv line for Garding 6/8 SWG GI wire. |
| 54 | FIXING OF EARTHING ROD AND WIRE AS PER RESPO MANUAL AND AS PER DIRECTION OF SUPERVISING ENGINEER INCLUDING THE COST OF LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 55 | fixing G.I.WIRE 8/10 SWG |
| 56 | FIXING 11 KV CROSS ARM. |
| 57 | 11 KV DISC INSULATOR. |
| 58 | 11 KV PIN INSULATOR. |
| 59 | Fabrication And Cutting/Drilling/Welding Of Ms Angle Iron T-Off Channel Etc. For Making Guarding Angle Of Various Size Including The Work Of Fixing The Bracket On Pcc/St Pole For Construction Of The Line. |
| 60 | LAYING OF 11 KV XLPE CABLE OTHER SIZE NEWLY ERECTED POLE AS PER RESPO MANUAL. |
| 61 | LAYING OF 11 KV XLPE CABLE RISER/OVERHEAD OTHER SIZE NEWLY ERECTED POLE AS PER RESPO MANUAL. |
| 62 | LAYING OF LT XLPE 3.5*240 SQ. MM. NEWLY ERECTED POLE AS PER RESPO MANUAL. |
| 63 | LAYING SAGGING STRINGING AND BINDING AND JUMPERING ETC OF FOLLOWING ACSR CONDUCTOR/WISEL/RABIT/ABC ALL SIZE ON THE NEWLY ERECTED POLES AS PER RESPO MANUAL AND AS PER DIRECTION OF SUPERVISING ENGINEER. IT INCLUDES THE COST OF LABOUR, T&P, CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 64 | ACSR DOG CONDUCTOR |
| 65 | ACSR REBBIT CONDUCTOR |
| 66 | ACSR WEASEL CONDUCTOR |
| 67 | LT ABC 3*120 SQ. MM. |
| 68 | LT ABC 3*95 SQ. MM. |
| 69 | LT ABC 3*50 SQ. MM. |
| 70 | LT LEAD 1*16 SQ. MM. |
| 71 | DISTRIBUTION BOX 3 PHASE COMPLET |
| 72 | MAKING JUMPERS ON SECTION POINTS, BY FIXING OF PROPER SIZES, SUITABLE FOR ACSR CONDUCTOR. SECTIONAL DOUBLE/FOUR POLE. |
| 73 | MAKING/FILLING OF 11 KV CABLE JOINTING KIT 3*185 SQ MM. XLPE CABLE. |
| 74 | MAKING/FILLING OF 11 KV CABLE JOINTING KIT 3*120 SQ MM. XLPE CABLE. |
| 75 | THE FOLLWING MATERIAL WILL BE FIXED BY THE CONTRACTOR. |
| 76 | PG CLAMP FOR DOG |
| 77 | Barbet Wire. |
| 78 | DISTRIBUTION BOX 3 PHASE COMPLET |
| 79 | Danger Board With Clamp, Nut And Bolt. |
| 80 | LT PVC SPACER |
| 81 | MS CHANNEL |
| 82 | ANGLE |
| 83 | L.T CLAMPS |
| 84 | LT INSULATORS |
| 85 | LT LUG. 16 SQ MM. |
| 86 | LT LUG. 240 |
| 87 | DEAD END CLAMP. |
| 88 | SUSPENSION CLAMP |
| 89 | Pearcing Connector. |
| 90 | J HOOK |
| 91 | F/SIDE BRACKET |
| 92 | GI PIPE 6\\" DIA |
| 93 | CLAMP FOR 11 KV LINE |
| 94 | NUT & BOLTS. |
| 95 | F CLAMP FOR 11 KV LINE |
| 96 | THE FOLLWING MATERIAL WILL BE PROVIDED BY THE CONTRACTOR. |
| 97 | PG CLAMP FOR DOG |
| 98 | Barbet Wire. |
| 99 | Danger Board With Clamp, Nut And Bolt. |
| 100 | LT PVC SPACER |
| 101 | MS CHANNEL |
| 102 | ANGLE |
| 103 | L.T CLAMPS |
| 104 | LT INSULATORS |
| 105 | LT LUG. 16 SQ MM. |
| 106 | LT LUG. 240 |
| 107 | DEAD END CLAMP. |
| 108 | SUSPENSION CLAMP |
| 109 | Pearcing Connector. |
| 110 | J HOOK |
| 111 | F/SIDE BRACKET |
| 112 | GI PIPE 6\\" DIA |
| 113 | CLAMP FOR 11 KV LINE |
| 114 | NUT & BOLTS. |
| 115 | F CLAMP FOR 11 KV LINE |
| 116 | CARTAGE & REMOVAL OF OLD & USED RECEIVED BACK MATERIAL FROM SITE TO STORE CENTRE/ J.E. STORE. |
| 117 | WEASEL CONDUCTOR SCRAP |
| 118 | LT ABC SCRAP |
| 119 | ABC SCRAP |
| 120 | RAIL POLE SCRAP OFF SIZE |
| 121 | STEEL POLE SCRAP |
| 122 | STP POLE OFF SIZE Please Enable Macros to View BoQ information |