| 1 | Shifting of Existing 2 Nos. LT Panels in Electrical Control Room of High-Rise (G+8) Basement to outer wall of the same room at minimum height of 1.25 metres from FFL (ground) involving dismantling, core-cutting & repair work as below along with disconnection & re-connection of LT power supply cables etc. complete as required along with providing double-compression type brass glands for cable entry & exit till shifting work is completed to the satisfaction of engineer-in-charge. Work Details : Construction of base frame for supporting wall-mounted LT panels including providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation blocks of size 300×300×450 mm including compaction and curing complete, fabricating, supplying and fixing 4 Nos. M.S. angle legs of size 50×50×6 mm including cutting, welding, drilling, aligning and erecting in position duly embedded in concrete with proper anchorage and grouted with cement slurry including applying one coat of red oxide primer and two or more coats of approved synthetic enamel paint complete, providing and laying brick masonry in cement mortar 1:6 using first class burnt clay bricks in infill between M.S. angle supports forming wall of approximate size 3.7 m length × 0.6 m thickness × 0.90 m height including scaffolding, raking of joints and curing complete, providing and constructing 2-step brick masonry staircase in cement mortar 1:6 with each step of size 300 mm tread × 150 mm riser including 12 mm thick cement plaster in cement mortar 1:4 on exposed surfaces with neat cement punning and finishing edges true and even including curing complete, and including backfilling, consolidation, finishing and all incidental works complete in all respects as per direction of Engineer-in-charge. |
| 2 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 3 | 4 X 35 sq. mm |
| 4 | 4 X 50 sq. mm |
| 5 | Supply of following XLPE insulated , XLPE/PVC sheathed Alumimium Conductor Armoured Power Cable of 1.1KV grade on surfece /recess/cable tray complete as required as per IS 7098. |
| 6 | 4 X 350 sq.mm |
| 7 | 4 X 95 sq.mm |
| 8 | 4 X 50 sq.mm |
| 9 | 4 X 35 sq.mm |
| 10 | Supplying of 10 Watt LED Aviation Light with Die-Cast Aluminum Housing with Red Polycarbonate Dome & Integral Driver operating at 140-270 V 50 Hz AC supply & having minimum IP 65 protection & minimum 50,000 hours life etc. complete as required. |
| 11 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 X 1.5 sq. mm |
| 13 | 3 X 4 sq. mm |
| 14 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 15 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of 36 watt Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 etc. as per DSR specifications complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 16 | Supplying and fixing 8 way (4 + 24), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole |
| 18 | Double pole |
| 19 | Triple pole and neutral |
| 20 | Laying and fixing one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size on wall surface complete as required. Upto 35 sq.mm (clamped with 1 mm thick saddle) |
| 21 | Supplying and fixing of 25 mm of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. Please Enable Macros to View BoQ information |