Tender For Installation Of 6 Mtr. Solar Street Light System 30W Solar Led Street Lighting System At (1) Rautari Gp, A) Booth No 219 Near Tetulberia Durga Mandir (2Pcs), B) Booth No 225 Tetulberia Primary School (2 Pcs), C) Booth No 225, Kamarpota Inf, Nadia-West Bengal
TDR : 55764816
Tender Notice
BOQ
Expired
Nadia
West Bengal
Tender For Installation Of 6 Mtr. Solar Street Light System 30W Solar Led Street Lighting System At (1) Rautari Gp, A) Booth No 219 Near Tetulberia Durga Mandir (2Pcs), B) Booth No 225 Tetulberia Primary School (2 Pcs), C) Booth No 225, Kamarpota Inf
Name of Work:- Installation of 6 mtr. Solar Street Light System 30W Solar LED Street Lighting System at (1) RAUTARI GP, a) Booth No 219 near Tetulberia Durga Mandir (2pcs), b) Booth no 225 Tetulberia Primary School (2 pcs), c) Booth no 225, Kamarpota Infront of Madhusudan House,(2) TATLA-2 GP, a) Booth no- 196, near Chakdaha Model School, b) Booth no. 201 Near Kanchan Ghosh House, c) Booth no. 207 near Kamalpur purba para (3pcs), d) Booth no 204 opposite of Raju Sarkar House, e) Booth no 189 at Vivekananda Club More, f) Booth no 208 at Joy Krishnapur, Paresh Sarkar House (2pcs), g) Booth no 211 Samasti pur (2pcs), h) Booth no. 201 Near Bandur Math Pratima Biswas House,(3) DUBRA- GP, a) Near Booth no 137 -at Sadar para, b) Booth no 143 at near Chittya Mondal House, c) Booth no 144 at near Purbapara Barowary Sangha, d) Booth no 145 at near Saroj Gosai House, e) Booth no 147 at near Ramdas House, f) Near Booth no 151 at Roy para more, g) Booth no 154 at near Durga Mandir, h) Booth no 157 at near Kali mandir, i) Booth no 160 at near Dipak Bala House, j) Booth no 161 at near Goutam Mondal House, k) Booth no 162 at near Sushen Ghosh House, l) Booth no 163 at near Milan majhi House, m) Booth no 164 at near Hari Mondal House, n) Booth no 165 at near Mahadeb Sardar House, o) Booth no 158 at near Parikhit Bala House, (4) SILINDA-I GP, a) Booth no 169 at near Chak Amdanga Pry School, b) Booth no 178 at near Harichand mandir, c) Booth no 171 at near Ashoke Sarkar House, d) Booth no 179 at near Biplab Sarkar house, e) Booth no 174 at near Roypara Kali Mandir, f) Booth no 184 at near Baliya Blood Donation C , g) Booth no 187 at near Bhadra Biswas house, h) Booth no 183 at near Bappa Mondal House,(5) SILINDA-II GP, a) Booth no 262 at near Balaram Bala House, b) Booth no 264 at near Kanai Sardar House, c) Booth no 268 at near Dilip Poddar House, d) Booth no 266 at near Nitai Hira House, e) Booth no 184 at near Shiv Mandir, f) Booth no 269 at near Putul Ghuha House, g) Booth no 261, near Parikhit Sardar House, h) Booth no 264 Near Srinagar Sitala Para Manasa Mandir,(6) TATLA-I GP, a) Booth no 128 at near Ashim Das House, b) Booth no 129 at near Donicha Roy Para, c) Booth no 132 at near Partha Karmakar House, d) Booth no 123 at near Hiren Sarkar House, e) Booth no126 at near Khokon Singh House, f) Booth no 133 at ner Shiv Mandir, g) Booth no 136 at near Anganwari School, h) Booth no137, Infront Sukhen Das House (TOTAL 56Nos) in the Nadia District.
Sl. No.
Item Description
1
Module 100 WP(ERTL and Flash Tested) (Supplying and erection) of moduler panel.Supply of 100wp Poly/ Mono crystaline module with IEC 61219, IEC6173-1,2 compliance withI. The PV module shall contain crystalline silicon solar cells and must have a certificate of testing conforming to IEC 61219 EditionII. The power output of the module(s) under STC would be a minimum of 75 Wp at a load voltage* of 16.4 + 0.2 VIII. The open circuit voltage of the PV modules under STC would be 21.0 VoltsIV. The module efficiency would be 14.5%V. SPV module shall be highly reliable, lightweight and shall have a service life of more than 25 years. SPV modules shall have a limited power loss of not more than 10% of nominal output at the end of 10 years and not more than 20% at the end of 25 yearsVII The solar module shall be able to withstand the following environmental conditions normally encountered at site - Temp. extremes ranging from -100 C to +850 C Wind load -150 km/h Maximum mean hourly rainfall of 40 mm Humiditylevel upto 95%, (HR/ Vikram/Any MNRE Approved)VIII. Strip must contain the following detailsa) Name of Manufacturerb) Model or type numberc) Serial No.d) Year of make(Including cost of Panel mounting structure)
2
Supplying and fixing 30W Luminaries comparise of :a) 30W, LED (Philips/Osram/equivalent reputed make with BlS Certificatete)b) Charge controller and it should have over charge protection, deep discharge protection, Batterys reversed polerty protection. Load short circuit protection, Open circut protection, panel revers polarity protection. Over temperature protectionc) Automatic dusk to dawn controllin8 system to monitor the LED operation.
3
Supply and commissioning of LiPo4 Battery. LITHIUM FERRO Batteries 12.8V, 42AH. (The batteries having BIS Certificat).,The battary should have battery management system(BMS) with higher life expectancy, longer cycle life, low discharge rate and charge faster facilites. (MAKE- OKAYA/ Warree/ARTECH ENERGY/ AMTEK) Battary must have 5 years warranty period.
4
Supply and installation of G.I pole 6 m long, 100mm outer dia 3.6mm thick conforming to IS 1161: 2014 with corrosion proof galvanisation conforming IS 2629-1965 with pole cap at top and base plate 200mmx200mx10mm with CC foundation having 600mmX600mmX150mm thick CC (4:2:1) Base block below base plate with metal including CCwith metal chips (6:3:1) of size 600mm X 600mm X 1000mm below the ground level surrounding the pole and muffing 300mm dia. and 300 mm hight above ground level including 3mm thick neat cement finishing an dGI earth bolt after making drilled holes etc on pole & carrage of pole at work- site including incuding filling up the ecavatted earth pit with shifted soil and remaining properly
5
Cable & LugsProviding Cables (including cables from pole top to Panels on Roof top) and other electrical fixtures.2.5 sq mm copper standard pvc insulated and unsheathed wire will be used.(MAKE- MESCAB/ POLYCAB/ KEI) & Lugs as per requirement.
6
Installation of solar panel including connection of lighting Fixture, batteries and panel with commissioning and testing of the system
7
Sypplying, fixing & fixing display board or murblae Stone with suitable brick worksas per G.S.
8
Comprehensive maintenance (Atleast three comprehensivemaitenance per year)
9
Sub Total
10
GST 18%
11
CESS 1% Please Enable Macros to View BoQ information