Health and Family Welfare Government Departments Closing in 5 days TDR #55760606

Bids Are invited for Digital Radiography - Should Be Of Microcontroller Technology Driven Ultra High Frequency Generator. , Output 50 Kw Or More. , Kvp Range 40 Kv – 125 Kv Or Better , Ma Range: 10 To 630 Ma Or Better , Mas Range: 500 Mas Or More , I

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Jul 2026
5 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Digital Radiography - Should Be Of Microcontroller Technology Driven Ultra High Frequency Generator. , Output 50 Kw Or More. , Kvp Range 40 Kv – 125 Kv Or Better , Ma Range: 10 To 630 Ma Or Better , Mas Range: 500 Mas Or More , It Should Have Digital Display Or Kvp & Mas. , 8 Anatomical Programming Radiography Should Be Possible. , It Should Have Overload Protection , Digital Aec Should Be Available On Both Planes , X Ray Generator And X Ray Tube Should Be From The Same Manufacturer. , The X – Ray Tube Should Be Rotating Anode, Compatible With The Generator And Must Have Dual Focus. , Tube With Anode Heat Storage Capacity 200000 Hu Or Better. , Multi Leaf Collimator Having Led L /Bright Light Source And Auto Shut Provision For The Light. , It Should Be Floor Mounted Column Stand. (No Attachment To Ceiling And No Additional Wires Running/Dangling Around The Machine) , It Should Be Fully Counter Balanced Mechanism. , It Should Have Facility To Display Kv And Ma Selection And Display Facility On A 7 Inch Or More Touch Screen With Input Set Parameters. , The Cooling Period Between Two Exposures Should Be Minimum 15 Seconds , It Should Have Emergency Switch To Disable All Mechanical Movements During Emergency , It Should Have Indication For Error And Warning. , Table Should Be Fixed, With 4 Ways Floating Tabletop Facility , Should Have Minimum Capacity Of 200 Kgs. , The Unit Should Be Provided With Vertical Bucky (With Removable Grid Option) . , Dual Detector Digital Radiography System It Should Have Provision To Do Chest Radiography Without Grid. , Should Have In Built Bucky Tray Where Orientation Of Bucky Can Be Changed From Landscape To Portait Mode. It Should Have Facility For Detector Of Sizing 14 X 17. , The Detector Should Be Of Solid-State Flat Panel Detector Of Latest Technology With Amorphous Silicon And Scintillator Of Cesium Iodide , The Size Of The Detector Should Be 35 Cm X 43 Cm Or More. , The Resolution Should Be Minimum Of 3.0 Lines Pair/Mm , The Pixel Size Should Be 150 Micrometers Or Less. , Detector Quantum Efficiency (D.Q.E) Should Be More Than 72% @ Zero Line Pairs. , The Active Pixel Matrix Should Be 2.3K X 2.8K Or More. , Detector Should Have Ingress Protection Rating Of Ip68/Ipx3/Ip44 Or Better , Detector Should Have Point Load Bearing Capacity Of 100 Kgs Or Better , Detector And Acquisition Software Should Be From The Same Manufacturer For Better Image Quality And Patient Care. , The Digital Workstation Should Be Based On The Latest High-Speed Processors Of At Least 32 Bit. , It Should Have The Possibility Of Acquiring The Image From The Detector System With Auto Protocol Select. , It Should Have Image Storage Disk Of 500 Gigabyte Or More , The System Should Have Ready Dicom Interface And Networking Capability With Ris/His/Pacs. , Please Specify The Post Processing Functions Available. , The Console System Should Have Advance Ai Features Such As Identifying Lung Nodules, Pneumo Thorax ,Pleural Effusuion Etc. Automatically. , Workstation Must Be Provided For Image Processing, Image Display, Post Processing Functions And Net Working With Colour Monitor Lcd Type Size 18 With Matrix 1024X1024 , A Cd/Dvd – R/W Based Long Term Archiving Must Be Offered , Additional Workstation: Should Be Supplied With All Above Features Of Image Acquisition System With True Medical Grade 21 Inch Of Bigger Size Monitor Of 2Mp And Minimum 1000Cd. , Computer For Emr And Ris Purpose. (Qty. 1) , Online Ups With 30 Minutes Back Up For Computer System And Image Viewing Workstation , 50 Kva Or More Servo Stabilizer For The Whole System. , Quoting Vendor To Visit The Site Of Installation And Access Size Of Dr Room. , Aprons : , Should Perform Preventive Maintenance (2Nos) During Warranty & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares And Spare Parts ( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any. Costing To Be Submittted In The Financial Bid , Please Submit Pre Installation Requirements [Electrical, Hvac, Compressed Air Along With Air Pressure Mentioned), Water Requirement (Ro/Di/Distilled Water With Its Pressure, Flow Rate Per Hour) ; If Any Of The Above Is Essential] , Vendor To Provide Ups With Adequate Capacity, If Required For The Quoted Equipment. If Not Required, Vendor To Mention The Same. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved. , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tmh. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tmh. Before Submitting The Quotation,Bidders May Visit Tmh To Know Unloading And Installation Site. , Complete Decommissioning & Dismantling Of Existing Machine With Clearing The Debris/Scrap From The Respective Site Will Be Sole Responsibility Of The Vendor If Buyback. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty (Should Include Qa Qc Annually As Per Aerb Noms.) , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , Penalty Clause: Total Quantity : 1

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Jul-2026 15-Jul-2026
2 15-Jul-2026 22-Jul-2026

BOQ

Sl. No. Item TitleItem Description
1Should be of microcontroller technology driven ultra high frequency generator.Should be of microcontroller technology driven ultra high frequency generator.
2Output 50 KW or more.Output 50 KW or more.
3KVP range 40 KV – 125 KV or betterKVP range 40 KV – 125 KV or better
4mA Range: 10 to 630 mA or bettermA Range: 10 to 630 mA or better
5mAs Range: 500 mAs or moremAs Range: 500 mAs or more
6It should have digital display or KVP & mAs.It should have digital display or KVP & mAs.
78 Anatomical programming radiography should be possible.8 Anatomical programming radiography should be possible.
8It should have overload protectionIt should have overload protection
9Digital AEC should be available on both planesDigital AEC should be available on both planes
10X Ray Generator and X ray Tube should be from the same manufacturer.X Ray Generator and X ray Tube should be from the same manufacturer.
11The X – Ray tube should be rotating anode, compatible with the generator and must have dual focus.The X – Ray tube should be rotating anode, compatible with the generator and must have dual focus.
12Tube with anode heat storage capacity 200000 HU or better.Tube with anode heat storage capacity 200000 HU or better.
13Multi leaf collimator having LED lamp/bright light source and auto shut provision for the light.Multi leaf collimator having LED lamp/bright light source and auto shut provision for the light.
14It should be floor mounted column stand. (No attachment to ceiling and no additional wires running/dangling around the machine)It should be floor mounted column stand. (No attachment to ceiling and no additional wires running/dangling around the machine)
15It should be fully counter balanced mechanism.It should be fully counter balanced mechanism.
16It should have facility to display KV and mA selection and display facility on a 7” inch or more touch screen with input set parameters.It should have facility to display KV and mA selection and display facility on a 7” inch or more touch screen with input set parameters.
17The cooling period between two exposures should be minimum 15 secondsThe cooling period between two exposures should be minimum 15 seconds
18It should have emergency switch to disable all mechanical movements during emergencyIt should have emergency switch to disable all mechanical movements during emergency
19It should have indication for error and warning.It should have indication for error and warning.
20Table should be fixed, with 4 ways floating tabletop facilityTable should be fixed, with 4 ways floating tabletop facility
21Should have minimum capacity of 200 Kgs.Should have minimum capacity of 200 Kgs.
22The unit should be provided with vertical bucky (with Removable Grid option) .The unit should be provided with vertical bucky (with Removable Grid option) .
23Dual Detector Digital Radiography System It should have provision to do chest radiography without grid.Dual Detector Digital Radiography System It should have provision to do chest radiography without grid.
24Should have in built bucky tray where orientation of bucky can be changed from landscape to portait mode. It should have facility for detector of sizing 14'' x 17''.Should have in built bucky tray where orientation of bucky can be changed from landscape to portait mode. It should have facility for detector of sizing 14'' x 17''.
25The detector should be of solid-state flat panel detector of latest technology with amorphous silicon and scintillator of Cesium IodideThe detector should be of solid-state flat panel detector of latest technology with amorphous silicon and scintillator of Cesium Iodide
26The size of the detector should be 35 cm x 43 cm or more.The size of the detector should be 35 cm x 43 cm or more.
27The resolution should be minimum of 3.0 lines pair/mmThe resolution should be minimum of 3.0 lines pair/mm
28The pixel size should be 150 micrometers or less.The pixel size should be 150 micrometers or less.
29Detector Quantum Efficiency (D.Q.E) should be more than 72% @ Zero Line Pairs.Detector Quantum Efficiency (D.Q.E) should be more than 72% @ Zero Line Pairs.
30The active pixel matrix should be 2.3k x 2.8k or more.The active pixel matrix should be 2.3k x 2.8k or more.
31Detector should have Ingress Protection rating of IP68/IPX3/IP44 or betterDetector should have Ingress Protection rating of IP68/IPX3/IP44 or better
32Detector should have point load bearing capacity of 100 kgs or betterDetector should have point load bearing capacity of 100 kgs or better
33Detector and Acquisition software should be from the same manufacturer for better image quality and patient care.Detector and Acquisition software should be from the same manufacturer for better image quality and patient care.
34The digital workstation should be based on the latest high-speed processors of at least 32 bit.The digital workstation should be based on the latest high-speed processors of at least 32 bit.
35It should have the possibility of acquiring the image from the detector system with auto protocol select.It should have the possibility of acquiring the image from the detector system with auto protocol select.
36It should have image storage disk of 500 Gigabyte or moreIt should have image storage disk of 500 Gigabyte or more
37The system should have ready DICOM interface and networking capability with RIS/HIS/PACS.The system should have ready DICOM interface and networking capability with RIS/HIS/PACS.
38Please specify the post processing functions available.Please specify the post processing functions available.
39The Console system should have advance AI features such as identifying Lung nodules, pneumo thorax ,Pleural effusuion etc. automatically.The Console system should have advance AI features such as identifying Lung nodules, pneumo thorax ,Pleural effusuion etc. automatically.
40Workstation must be provided for image processing, image display, post processing functions and net working with colour monitor LCD type size 18” with matrix 1024x1024Workstation must be provided for image processing, image display, post processing functions and net working with colour monitor LCD type size 18” with matrix 1024x1024
41A CD/DVD – R/W based long term archiving must be offeredA CD/DVD – R/W based long term archiving must be offered
42Additional Workstation: Should be supplied with all above features of image acquisition system with true medical grade 21 inch of bigger size monitor of 2MP and minimum 1000cd.Additional Workstation: Should be supplied with all above features of image acquisition system with true medical grade 21 inch of bigger size monitor of 2MP and minimum 1000cd.
43Computer for EMR and RIS purpose. (Qty. 1)Computer for EMR and RIS purpose. (Qty. 1)
44Online UPS with 30 minutes back up for computer system and image viewing workstationOnline UPS with 30 minutes back up for computer system and image viewing workstation
4550 KVA or more Servo Stabilizer for the whole system.50 KVA or more Servo Stabilizer for the whole system.
46Quoting Vendor to visit the site of installation and access size of DR room.Quoting Vendor to visit the site of installation and access size of DR room.
47Aprons :Aprons :
48Should perform preventive maintenance (2nos) during warranty & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.Should perform preventive maintenance (2nos) during warranty & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.
49Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.
50Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance.Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance.
51Vendor to submit list of consumables/consumable Spares and spare parts ( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any. Costing to be submittted in the financial bidVendor to submit list of consumables/consumable Spares and spare parts ( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any. Costing to be submittted in the financial bid
52Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]
53Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same.Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same.
54Vendor to submit details of footprint size & weight of the quoted model.Vendor to submit details of footprint size & weight of the quoted model.
55Vendor to submit power consumption.Vendor to submit power consumption.
56Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.
57User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.
58Predispatch inspection at factory will be required if desired by authorities.Predispatch inspection at factory will be required if desired by authorities.
59Should be CE/US FDA/BIS/ICMED approved.Should be CE/US FDA/BIS/ICMED approved.
60Vendor should provide the User manual and service manual copy during the installation of the equipment.Vendor should provide the User manual and service manual copy during the installation of the equipment.
61Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH. If needed ,bidder has to arrange for the labours at no charge to TMH. Before submitting the quotation,bidders may visit TMH to know unloading and installation site.Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH. If needed ,bidder has to arrange for the labours at no charge to TMH. Before submitting the quotation,bidders may visit TMH to know unloading and installation site.
62Complete decommissioning & dismantling of existing machine with clearing the debris/scrap from the respective site will be sole responsibility of the vendor if buyback.Complete decommissioning & dismantling of existing machine with clearing the debris/scrap from the respective site will be sole responsibility of the vendor if buyback.
63Training:Training:
64Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.
65Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.
66Warranty- 2 yearsWarranty- 2 years
67CMC- cost per annum will be considered for all bidders for 8 years after warranty (Should include QA QC annually as per AERB noms.)CMC- cost per annum will be considered for all bidders for 8 years after warranty (Should include QA QC annually as per AERB noms.)
68Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.
69Penalty Clause:Penalty Clause:

AI Tender Summary

OUR REF NO 55760606
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 22-07-2026
Authority
Authority Name Tata Memorial Centre
Work Description Bids Are invited for Digital Radiography - Should Be Of Microcontroller Technology Driven Ultra High Frequency Generator. , Output 50 Kw Or More. , Kvp Range 40 Kv – 125 Kv Or Better , Ma Range: 10 To 630 Ma Or Better , Mas Range: 500 Mas Or More , It Should Have Digital Display Or Kvp & Mas. , 8 Anatomical Programming Radiography Should Be Possible. , It Should Have Overload Protection , Digital Aec Should Be Available On Both Planes , X Ray Generator And X Ray Tube Should Be From The Same Manufacturer. , The X – Ray Tube Should Be Rotating Anode, Compatible With The Generator And Must Have Dual Focus. , Tube With Anode Heat Storage Capacity 200000 Hu Or Better. , Multi Leaf Collimator Having Led L /Bright Light Source And Auto Shut Provision For The Light. , It Should Be Floor Mounted Column Stand. (No Attachment To Ceiling And No Additional Wires Running/Dangling Around The Machine) , It Should Be Fully Counter Balanced Mechanism. , It Should Have Facility To Display Kv And Ma Selection And Display Facility On A 7 Inch Or More Touch Screen With Input Set Parameters. , The Cooling Period Between Two Exposures Should Be Minimum 15 Seconds , It Should Have Emergency Switch To Disable All Mechanical Movements During Emergency , It Should Have Indication For Error And Warning. , Table Should Be Fixed, With 4 Ways Floating Tabletop Facility , Should Have Minimum Capacity Of 200 Kgs. , The Unit Should Be Provided With Vertical Bucky (With Removable Grid Option) . , Dual Detector Digital Radiography System It Should Have Provision To Do Chest Radiography Without Grid. , Should Have In Built Bucky Tray Where Orientation Of Bucky Can Be Changed From Landscape To Portait Mode. It Should Have Facility For Detector Of Sizing 14 X 17. , The Detector Should Be Of Solid-State Flat Panel Detector Of Latest Technology With Amorphous Silicon And Scintillator Of Cesium Iodide , The Size Of The Detector Should Be 35 Cm X 43 Cm Or More. , The Resolution Should Be Minimum Of 3.0 Lines Pair/Mm , The Pixel Size Should Be 150 Micrometers Or Less. , Detector Quantum Efficiency (D.Q.E) Should Be More Than 72% @ Zero Line Pairs. , The Active Pixel Matrix Should Be 2.3K X 2.8K Or More. , Detector Should Have Ingress Protection Rating Of Ip68/Ipx3/Ip44 Or Better , Detector Should Have Point Load Bearing Capacity Of 100 Kgs Or Better , Detector And Acquisition Software Should Be From The Same Manufacturer For Better Image Quality And Patient Care. , The Digital Workstation Should Be Based On The Latest High-Speed Processors Of At Least 32 Bit. , It Should Have The Possibility Of Acquiring The Image From The Detector System With Auto Protocol Select. , It Should Have Image Storage Disk Of 500 Gigabyte Or More , The System Should Have Ready Dicom Interface And Networking Capability With Ris/His/Pacs. , Please Specify The Post Processing Functions Available. , The Console System Should Have Advance Ai Features Such As Identifying Lung Nodules, Pneumo Thorax ,Pleural Effusuion Etc. Automatically. , Workstation Must Be Provided For Image Processing, Image Display, Post Processing Functions And Net Working With Colour Monitor Lcd Type Size 18 With Matrix 1024X1024 , A Cd/Dvd – R/W Based Long Term Archiving Must Be Offered , Additional Workstation: Should Be Supplied With All Above Features Of Image Acquisition System With True Medical Grade 21 Inch Of Bigger Size Monitor Of 2Mp And Minimum 1000Cd. , Computer For Emr And Ris Purpose. (Qty. 1) , Online Ups With 30 Minutes Back Up For Computer System And Image Viewing Workstation , 50 Kva Or More Servo Stabilizer For The Whole System. , Quoting Vendor To Visit The Site Of Installation And Access Size Of Dr Room. , Aprons : , Should Perform Preventive Maintenance (2Nos) During Warranty & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares And Spare Parts ( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any. Costing To Be Submittted In The Financial Bid , Please Submit Pre Installation Requirements [Electrical, Hvac, Compressed Air Along With Air Pressure Mentioned), Water Requirement (Ro/Di/Distilled Water With Its Pressure, Flow Rate Per Hour) ; If Any Of The Above Is Essential] , Vendor To Provide Ups With Adequate Capacity, If Required For The Quoted Equipment. If Not Required, Vendor To Mention The Same. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved. , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tmh. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tmh. Before Submitting The Quotation,Bidders May Visit Tmh To Know Unloading And Installation Site. , Complete Decommissioning & Dismantling Of Existing Machine With Clearing The Debris/Scrap From The Respective Site Will Be Sole Responsibility Of The Vendor If Buyback. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty (Should Include Qa Qc Annually As Per Aerb Noms.) , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , Penalty Clause: Total Quantity : 1
Basic Detail
Tender No GEM/2026/B/7602089
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 15 Jul 2026
Submission Date 22 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.77 Lakhs
Exemption Available
Document List
f271204d-d695-4c1d-ab2b-56f834897e0e.pdf
1780124310.xlsx
digital_radiography_tech_specs_2026-05-30-12-15-36_59e9f5c8a85c5906bbefb88bb979a897.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 22, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

f271204d-d695-4c1d-ab2b-56f834897e0e.pdf

xlsx

1780124310.xlsx

xlsx

digital_radiography_tech_specs_2026-05-30-12-15-36_59e9f5c8a85c5906bbefb88bb979a897.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders