| 1 | Operation & routine maintenance of D.G. sets, Mechanical Ventilation system & LT Supply i/c accessories as per inventory and terms & conditions enclosed herewith. |
| 2 | Operation and routine maintenance of street light, park lights, common area, basement area(dewatering pumps & lighting), compound lights i/c accessories as per inventory and terms & conditions enclosed herewith. |
| 3 | Operation & routine maintenance maintenance of Clear water Supply, Submersile pumps, Tubewell supply i/c accessories as per inventory and terms & conditions enclosed herewith. |
| 4 | Supply of high speed diesel for operation of DG Sets i/c cartage, filling etc complete as required. |
| 5 | Repair & servicing of fire fighting panel of ASPL make at site including replacement of damaged/stolen Battery charger & Annuciator etc. from OEM/OEM authorized dealer including testing & commissioning etc. complete as required. |
| 6 | Repair & Servicing of AMF panel at site including replacement of damaged, stolen EC-2 Relay & Ammeter etc.from OEM/OEM authorized dealer including testing & commissioning etc. complete as required. |
| 7 | Repair & servicing of ATS Panel at site including servicing of 250A ATS from OEM/OEM authorized dealer etc. including testing & commissioning etc. complete as required. |
| 8 | Repair & servicing of Lift Panel at site including replacement of damaged/stolen MCCB, Aluminium Busbar, Power & Control wiere & CT's etc. from OEM/OEM authorized dealer including testing & commissioning etc. complete as required. |
| 9 | Rewinding of 3 H.P. dewatering pump sets Kirloskar make i/c replacement of mechanical seal,ball bearing,ruuber parts,pump repair,lubricant oil, dismantling & re-assembling etc. with testing & commisioning complete as required . |
| 10 | Rewinding of 10 H.P./12 B.H.P dewatering pump sets Kirloskar make i/c replacement of mechanical seal,ball bearing,ruuber parts,pump repair,lubricant oil, dismantling & re-assembling etc. with testing & commisioning complete as required . |
| 11 | Supply of following sizes canvass pipe for watering purpose from submersible p/sets. |
| 12 | 150 mm |
| 13 | 100 mm |
| 14 | Supply & replacement of the following parts of 2 Nos. D.G. sets 140 K.V.A capacity (Kirloskar make) by the OEM/OEM authorized dealer i/c testing and commissioning etc. complete as required(The rates are inclusive of rebate of material component). |
| 15 | LUB OIL FILTER- 6H.1193.02.0.00 |
| 16 | LUB OIL FILTER ELEMENT- 06.436.01.0.00 |
| 17 | FUEL FILTER MICRO- 3H.132.01.0.00 |
| 18 | FUEL FILTER PRE- 3H.132.01.0.00 |
| 19 | FUEL FILTER ELEMENT- 4H.2206.01.0.00 |
| 20 | AIR FILTER ELEMENT- 6H.413.30.0.00 |
| 21 | BATTERY 12V 180 AH - 02.731.33.0.00 |
| 22 | CANOPY LOCK - 02.759.22.0.00 |
| 23 | KIRLOSKAR OIL-20 LIT- 82.060.10.0.13 |
| 24 | KIRLOSKAR COOLANT 26 LIT- 82.020.35.1.26 |
| 25 | ACTUATOR- 6H.1003.01.0.00 |
| 26 | ENGINE CONTROL UNIT- 6H.1003.04.0.00 |
| 27 | ECU ELECTRONIC GOVERNOR- 6H.1003.02.0.00 |
| 28 | COLD STARTING KIT- 4H. 1684.71.0.SP |
| 29 | FUEL PUMP REPAIR |
| 30 | SERVICE CHARGES |
| 31 | FREIGHT |
| 32 | RADIATOR DESCALING |
| 33 | Supply & replacement of the following parts of 2 Nos. D.G. sets 320 K.V.A capacity (Kirloskar make) by the OEM/OEM authorized dealer i/c testing and commissioning etc. complete as required(The rates are inclusive of rebate of material component). |
| 34 | LUB OIL FILTER- DV0.014.11.0.00 |
| 35 | FUEL FILTER MICRO- DV8.040.24.0.00 |
| 36 | FUEL FILTER ELEMENT- 4H.2206.01.0.00 |
| 37 | AIR FILTER ELEMENT PRE- DV8.505.74.0.00 |
| 38 | AIR FILTER ELEMENT SEC- DV8.505.75.0.00 |
| 39 | SET OF COPPER WASHER- 47.094.30.0.00 |
| 40 | KIRLOSKAR OIL-50 LIT- 82.060.10.050 |
| 41 | KIRLOSKAR COOLANT 26 LIT- 82.020.35.1.26 |
| 42 | BATTERY 12V 180 AH- 02.731.33.0.00 |
| 43 | SERVICE CHARGES |
| 44 | FREIGHT |
| 45 | RADIATOR DESCALING |
| 46 | Supply & replacement of the following parts of diesel Engine pump set of rating 70.5 KW (Kirloskar make) ,Head-110 mtr. ,discharge-2850 LPM i/c testing and commissioning etc. as required(The rates are inclusive of rebate of material component). |
| 47 | LUB OIL FILTER- DV0.014.11.0.00 |
| 48 | FUEL FILTER MICRO- DV8.040.24.0.00 |
| 49 | FUEL FILTER ELEMENT- 4H.2206.01.0.00 |
| 50 | AIR FILTER ELEMENT PRE- DV8.505.74.0.00 |
| 51 | AIR FILTER ELEMENT SEC- DV8.505.75.0.00 |
| 52 | SET OF COPPER WASHER- 47.094.30.0.00 |
| 53 | KIRLOSKAR OIL-50 LIT- 82.060.10.050 |
| 54 | KIRLOSKAR COOLANT 26 LIT- 82.020.35.1.26 |
| 55 | BATTERY 12V 180 AH- 02.731.33.0.00 |
| 56 | SERVICE CHARGES |
| 57 | FREIGHT |
| 58 | Dismantling and fitting 15 H.P. clear water pump set(Kirloskar make) i/c loading, unloading, rewinding of motor,balancing of rotor,pump repair,replacement of mechanical seal,ball beaings testing and commissioning etc. complete as required. |
| 59 | Supplying,installation of 1 H.P. dewatering monobloc pump set of crompton make having specifications 40 mm x 40 mm (suc. X del.),3000 rpm,15 mm solid handling capacity,head range-10-16 m,discharge (342-144)LPM with testing & commissioning etc. as required. |
| 60 | Supplying and fixing 3C x 2.5 sq. mm.1100 V PVC insulated & sheathed copper conductor submersible cable through saddling with testing & commissioning etc. as required. |
| 61 | Supplying,installation of compact control panel having specifications relay range of (9-14) m with testing & commissioning etc. as required. |
| 62 | Supplying of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) 18W-22W LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 63 | Supplying and drawing of following size FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 64 | 1 x 1.5 sq. mm |
| 65 | 3 x 1.5 sq. mm |
| 66 | Supplying & installation of 7.5 KW/10 H.P. Three phase sewage non-clog pump set(with cutting blades) having specifications of delivery size -150 mm,max.head range-15 m,max. discharge 3800 LPM i/c testing & commissioning etc. complete as required. |
| 67 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 68 | 20 mm |
| 69 | 25 mm |
| 70 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 71 | 5/6 amps switch |
| 72 | 15/16 A switch |
| 73 | 3 pin 5/6 A socket outlet |
| 74 | 6 pin 15/16 A socket outlet |
| 75 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 76 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit includingdismantling as required.Group A |
| 77 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 78 | Single pole |
| 79 | Triple pole and neutral |
| 80 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 81 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 82 | Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. |
| 83 | 4 x 16 sq. mm |
| 84 | 4 x 25 sq.mm |
| 85 | 3.5 x120 sq. mm. |
| 86 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 87 | 4 X 16 sq. mm (28mm) |
| 88 | 4 X 25 sq. mm (28mm) |
| 89 | 3½ X 120 sq. mm (45mm) |
| 90 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 91 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 92 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 93 | Painting of MS pipe along with brackets,clamps etc of following size fire fighting pipe with red oxideprimer after making the surface smooth, cleaning with proper sand paper/suitable material complete etc.as required. |
| 94 | 300 mm dia. |
| 95 | 150 mm dia. |
| 96 | 100 mm dia. |
| 97 | 80 mm dia. |
| 98 | 65 mm dia. |
| 99 | 40/50 mm dia. |
| 100 | 25/32 mm dia. |
| 101 | Painting of M.S. 300 mm dia. Hose reel drum with brackets, clamps with 2 coats of synthetic enamel red paint after making surface smooth complete etc. |
| 102 | Painting of Double Door M.S. Fire Hydrant/Hose box complete with Red oxide primer after making the surface smooth, cleaning with proper sand paper/suitable material complete etc.as required. |
| 103 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.250 A,50KA,FPMCCB Please Enable Macros to View BoQ information |