| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Exicutive officer Nagar Panchayat Phulpur Prayagraj Name of Work:-Construction of Toilet in ward no.03 Shekhpur Pashchmi . Contract No:May26PHP3 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No. Item Description Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | A-Civil Work |
| 3 | Excavation in foundation in ordinary soil loam clay or sand including lift upto 1.50 metre and lead upto 30 Mtr. Including filling watering and ramming of excavated earth into the trenches of into the space between the building and the sides of foundati trenches or into the plinth and removal & disposal of surplus earth as directed by the Engineer incharge upto a distance of 30m from the foundation trenches(Excluding Royalty)..As per DSR 2.6.1 |
| 4 | Earth work in cutting or in embankment in ordinary soil, excavtion to be in the form of regular pits not exceeding 0.50 mtr. In depth and earth work in embankment to be in 20 cm. Layers, including ramming and dressing the surface to required levels and slops and also including 1.5 meter lift and 30 meter lead the earth from cutting to be used in making embankment or to be deposited as spoil bank within 30 meter distance as directed by Engineer incharge.with 5.0.km cortege As per DSR 2.25(a) |
| 5 | Concrete with 4 cm gauge brick ballast fine sand of 1.25 F.M. and cement in proportion of 1:4:8 in foundations and under floors including supply of all materials, labour, tools & plants etc. required for proper completion of the work.As per DSR No.4.1.8 |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering , finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR-5.3 |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | 12 mm thick cement plaster with cement, and fine sand of 1:25 F.M Mortar in 1:4 cement and fine sand morar including supply of all materials, labour, tools & plants etc. required for proper completion of the work. in complete. As per DSR. No.13.4.1 |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR-5.3 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering , finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR-5.3 |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering , finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR-5.3 |
| 13 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V levelCement mortar 1:4 (1 cement :4 coarse sand) |
| 14 | Mild steel or iron in Plain work such as RCC or R.B. work(when not inclded in an over all rates) wrought torequired shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping and hooks... As per DSR No.5.22.6 |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | 12 mm thick cement plaster with cement, and fine sand of 1:25 F.M Mortar in 1:4 cement and fine sand morar including supply of all materials, labour, tools & plants etc. required for proper completion of the work. in complete. As per DSR. No.13.4.1 |
| 17 | Cement concrete with 2cm gauge approved stone grit, coarse sand and cement in proportions of 4:2:1 including supply of all materials, labour, tools & plant etc required for proper completion of the work As per DSR No.4.2.3 |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water bsorption less than 0.08% and conforming to IS:15622, of approved make, in all olours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete |
| 19 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even As DSR 13.26 |
| 20 | Distempring (First coat) with oil bound distemper of approved brand and manufacture and equired shade on undecoted wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger,J&N Shalimar,Asian paint,after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including prepairing the surface even with Plaster of paris or approved synthetic material and sand prapered smooth including cost of material As per DSR no 13.41.1 |
| 21 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) : .As per D.S.R.21.3.2 |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter As per DSR-12.41.2 |
| 23 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture As per DSR-13.48.3 |
| 24 | B- Electrification |
| 25 | Wiring for light point/ fan point/exhaust fan point/call bell point/plug point with 15 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc as required. |
| 26 | Wiring for twin control light point with 1.5sq.mm.FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 27 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required for inverter Wiring: 1x1.5 mm |
| 28 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular swifch, connections etc. as required. |
| 29 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required for AC/Power |
| 30 | 2+4 way, SPN, single door, MCB DB |
| 31 | 63 A, rating, 4 pole RCCB, 30mA |
| 32 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc.as required. For 4 way Double door TPN MCBDB |
| 33 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required2X6 sq. mm 1X6 sq.mm.earth wire |
| 34 | Wiring for circult submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 10 sq. mm 1 X 6 sq. mm earth wire |
| 35 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 16 sq. mm + 1X 6 sq. mm earth wire |
| 36 | Aluminium lugs for 10 sq. mm cable |
| 37 | Aluminium lugs for 16 sq. mm cable |
| 38 | S/F of electronic fan regulator 120-280 V ISI marked |
| 39 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 40 | S/F of LED Bulb 15 watt |
| 41 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 42 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.). insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 43 | Supply and Installation of Exhaust Fan |
| 44 | Add 6.50% Sanitary fitting |
| 45 | GST Total in Figures 2557813.0 2557813.0 INR Twenty Five Lakh Fifty Seven Thousand Eight Hundred & Thirteen Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |