| 1 | SAFE CARRIAGE OF S.T./PCC POLE FROM STORE CENTER TO SITE STORE WITH LOADING & UNLOADING AT BOTH ENDS RESPECTIVELY DISTANCE WITHIN- 0 TO 50 KMS. |
| 2 | ST POLES 13 MTR. LONG |
| 3 | PCC POLES 11 MTR. LONG |
| 4 | PCC POLES 8.5 MTR. LONG |
| 5 | LOADING, SAFE CARRIAGE & UNLOADING OF HEAVY STOCK MATERIAL V TYPE, DISC INSULATOR, PIN INSULATOR ETC. FROM STORE CENTER TO SITE STORE WITH PROPER STACKING OF MATERIAL, DISTANCE WITHIN-50KMS. |
| 6 | LOADING, SAFE CARRIAGE & UNLOADING OF LT/HT CABLE, VCB & CONTROL PANAL ETC FROM STORE CENTER TO SITE STORE WITH PROPER STACKING OF MATERIAL, DISTANCE WITHIN-50KMS. |
| 7 | 11 KV VCB INCOMING/OUTGOING |
| 8 | ACSR RABBIT CONDUCTOR |
| 9 | ACSR DOG CONDUCTOR |
| 10 | ACSR WEASEL CONDUCTOR |
| 11 | 11 KV XLPE CABLE OF 3X185 SQ.MM. |
| 12 | HDPE PIPE 120 MM. (PN-6) |
| 13 | ERECTION OF SINGLE POLE ST/PCC POLE 11/ 33 KV FITTINGS AS PER RESPO DRAWING TOP CHANNAL, DROPPER CHANNAL, X BRACING SET, DISC INSULATOR, PIN INSULATOR, GUARDING ANGLE F BRACKET AND ETC AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 14 | ST POLES 13 MTR. LONG |
| 15 | PCC POLES 11 MTR. LONG |
| 16 | PCC POLES 8.5 MTR. LONG |
| 17 | ERECTION OF DOUBLE POLE / SACTION POLE OF 11/33 KV FITTINGS AS PER RESPO DRAWING TOP CHANNAL, DROPPER CHANNAL, X BRACING SET, DISC INSULATOR, PIN INSULATOR, GUARDING ANGLE F BRACKET AND ETC AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS. |
| 18 | PCC POLES 11 MTR. LONG |
| 19 | PCC POLES 8.5 MTR. LONG |
| 20 | EXCAVATION OF FOR EACH AND GROUTING OF SINGLE POLE AS PER RESPO DRAWING AND AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE PAD ETC. AS PER ACTUAL SITE REQUIREMENT AND PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 21 | ST POLES 13 MTR. LONG |
| 22 | PCC POLES 11 MTR. LONG |
| 23 | PCC POLES 8.5 MTR. LONG |
| 24 | EXCAVATION OF FOR EACH AND GROUTING OF DOUBLE POLE/SACTION POLE AS PER RESPO DRAWING AND AS PER DIRECTION OF ENGINEER INCHARGE INCLUDING THE COST OF LABOUR, T&P AND CARRIER ETC. THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE PAD ETC. AS PER ACTUAL SITE REQUIREMENT AND PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 25 | PCC POLES 11 MTR. LONG |
| 26 | PCC POLES 8.5 MTR. LONG |
| 27 | FIXING OF 11 KV STAY SET INCLUDING NOZELLING ETC. AND ALSO INCLUDING THE COST OF ALL GROUTING MATERIAL, LABOUR, T&P ETC REQUIRED FOR PROPER COMPLETION OF WORK AND PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 28 | GROUTING OF 11 KV STAY SET INCLUDING NOZELLING ETC. AND ALSO INCLUDING THE COST OF ALL THE SUPPORT SHALL BE GROUTED WITH CEMENT, SAND AND STONE BALLAST IN RATIO 1:4:8 INCLUDING THE COST OF CEMENT, SAND, STONE BALLAST, STONE ETC. AS PER ACTUAL SITE REQUIREMENT , LABOUR, T&P ETC REQUIRED FOR PROPER COMPLETION OF WORK AND PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 29 | FIXING OF EARTHING ROD AND WIRE AS PER DIRECTION OF SUPERVISING ENGINEER INCLUDING THE COST OF LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF WORK AND PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 30 | INSTALLATION OF VCB (INCOMING/OUTGOING) TO ALL SIZE OF VCB & T/F AT DIFFERENT SITE. |
| 31 | FIXING 33 KV PIN INSULATOR |
| 32 | FIXING 33 KV CROSS ARM. |
| 33 | G.I.WIRE 8/10 SWG |
| 34 | FIXING 11 KV CROSS ARM. |
| 35 | 11 KV DISC INSULATOR. |
| 36 | 11 KV PIN INSULATOR. |
| 37 | FILLING OF 11 KV STRAIGHT THROUGH |
| 38 | FILLING OF 11 KV INDOOR/OUTDOOR JOINTING KIT |
| 39 | CUTTING /DRILLING /WELDING OF MS ANGLE IRON FOR MAKING GUARDING ANGLE SIZE 65X65X6/50X50X6 MM INCLUDING THE WORK OF FIXING THE BRACKET ON PCC/ST POLE FOR CONSTRUCTION OF THE LINE. |
| 40 | FABRICATION OF T-OFF CHANNEL |
| 41 | MAKING OF PLINTH FOR VCB (INCOMING/OUTGOING) |
| 42 | LAYING SAGGING STRINGING AND BINDING AND JUMPERING ETC OF FOLLOWING ACSR CONDUCTOR/WISEL/RABIT/ABC ALL SIZE ON THE NEWLY ERECTED POLES AS PER DIRECTION OF SUPERVISING ENGINEER. IT INCLUDES THE COST OF LABOUR, T&P, CARRIER ETC. REQUIRED FOR PROPER COMPLETION OF WORK AS PER RESSPO MANUALS |
| 43 | ACSR RABIT CONDUCTOR |
| 44 | ACSR DOG CONDUCTOR |
| 45 | ACSR WISEL CONDUCTOR |
| 46 | U/G CABLE WORK OF 11 KV LINE DETAIL ARE BLOW |
| 47 | LAYING AND PULLING OF 11 KV XLPE CABLE OFF SIZE THROUG HDPE PIPE |
| 48 | DRILLING OF TWO PARALLEL BORES BY TRENCH LESS METHOD BY HORIZANTAL BORING BY HDD MACHINE AT RESPO GROUND LEVEL |
| 49 | LAYING & FIXING OF HDPE PIPE FOR 11 KV CABLE OFF SIZE |
| 50 | PROVIDING & FIXING AND INTERCONNECTING 6 MTR. LONG PIECES OF HDPE PIPE SHOCKET. |
| 51 | DIGGING OF PITS OF SIZE 4 MTR X 4 MTR X 1.5 MTR. FOR CABLE LOOP |
| 52 | RESTORATION OF PIT AFTER LAYING OF CABLE LOOP |
| 53 | RESTORATION OF KACHA ROAD AFTER LAYING OF CABLE. |
| 54 | RESTORATION OF PAKKA ROAD AFTER LAYING OF CABLE. |
| 55 | FIXING OF 11 KV FUSE SET |
| 56 | GUARDING OF 11/33 KV LINE |
| 57 | FIXING OF GUARDING ANGLE |
| 58 | PROVIDING OF GI-HOOK FOR GUARDING. |
| 59 | THE FOLLWING MATERIAL WILL BE FIXED BY THE CONTRACTOR. |
| 60 | BARBED WIRE |
| 61 | ALUMINIUM BINDING WIRE |
| 62 | PG CLAMP FOR DOG |
| 63 | F-CLAMP FOR 33 KV LINE |
| 64 | F-BRACKET FOR 33 KV LINE |
| 65 | DANGER BOARD WITH CLAMP |
| 66 | RED OXIDE |
| 67 | ALUMINIUM PAINT |
| 68 | BUS BAR FOR 11 KV LINE |
| 69 | GI PIPE 6\\" DIA |
| 70 | F-CLAMP FOR 11 KV LINE |
| 71 | CLAMP FOR 11 KV LINE |
| 72 | NUMBER PLATE |
| 73 | DANGER BOARD WITH CLAMP |
| 74 | THE FOLLWING MATERIAL WILL BE PROVIDED BY THE CONTRACTOR. |
| 75 | BARBED WIRE |
| 76 | ALUMINIUM BINDING WIRE |
| 77 | PG CLAMP FOR DOG |
| 78 | F-CLAMP FOR 33 KV LINE |
| 79 | F-BRACKET FOR 33 KV LINE |
| 80 | DANGER BOARD WITH CLAMP |
| 81 | RED OXIDE |
| 82 | ALUMINIUM PAINT |
| 83 | BUS BAR FOR 11 KV LINE |
| 84 | PROVIDING OF HDPE PIPE 120 MM. (PN-6) |
| 85 | GI PIPE 6\\" DIA |
| 86 | F-CLAMP FOR 11 KV LINE |
| 87 | CLAMP FOR 11 KV LINE |
| 88 | NUMBER PLATE |
| 89 | DANGER BOARD WITH CLAMP |
| 90 | CARTAGE & REMOVAL OF OLD & USED RECEIVED BACK MATERIAL FROM SITE TO STORE CENTRE/ J.E. STORE. |
| 91 | STEEL SCRAP |
| 92 | DAMAGED STP SCRAP |
| 93 | IRON SCRAP Please Enable Macros to View BoQ information |