| 1 | DSR Item No.1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 2.5 sq. mm |
| 3 | DSR ITEM NO.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 50 mm |
| 5 | DSR item no.2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 6 | 100 A,30KA,FPMCCB |
| 7 | DSR Item No. 2.4Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/ Isolator). |
| 8 | 4 way (4 + 12), Double door |
| 9 | 6 way (4 + 18), Double door |
| 10 | DSR Item No. 2.10Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | Single pole |
| 12 | Triple pole and neutral |
| 13 | DSR item No. 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 14 | DSR item No. 5.7Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 15 | DSR item no.5.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 16 | DSR Item No 7.4Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 17 | 1 output per phase and suitable for single phase supply |
| 18 | DSR item no.8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 19 | 90 watt |
| 20 | DSR item no.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 21 | 100 watt |
| 22 | 150 watt |
| 23 | 200 watt |
| 24 | DSR Item No 15.16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 25 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 26 | Supply and erection of Contactor T AC3 70 AMP RATING AND 100 AMPS RATING FOR AC1 unit suitable for 3 phase switching on/off. The job includes cost of 1 no. 3 phase MNX 70 CS97076 with built in SURGE SUPPRESSOR for coil of 220 Volt 50/60 Hz Rating Lauritz Knudsen/ Siemens 3TF/ ABB AX series. The contactor shall be installed on existing bakelite sheet with help nut and bolt. The job includes making incoming and outgoing connection with suitable copper wire and other petty material require to complete the job to the entire satisfaction of Engineer- in- charge. |
| 27 | Supply and Erection of sheet metal cubical pedestal of suitable dimensions made from 50x50x6mm thick MS angle iron frame on the base of pedestal, covered with 16 gauge MS sheet duly welded on five sides and front side hinged complete with locking arrangement 4 nos. switchgear supporting members each of MS flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs made out from 50x50x6 mm thick MS angle iron each 60 cm long including painting bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete platform of suitable dimensions 15cm high from ground level and 45 cm thick. The cubical pedestal shall be 15cm from the top of cement concrete platform. The shutter of the cubicle pedestal should be of ‘U’ shape supported from internal side for additional strength with 16 GMS sheet. |
| 28 | Cubical size 1200 mm x 900 mm x 350 mm deep. |
| 29 | Supply & fixing of OEM made Junction box IP-66/67 made out of Polycarbonate with Glass fiber reinforced of size 130 x180 x 77mm (minimum) with 5 Nos. OEM made connectors/ terminal blocks. The Jn. Box and connectors/terminal blocks should be supplied by OEM. The terminal blocks/ connectors should be of Hensel / Wago / Elmax / Siemens make only and junction box shall be of Hensel make KF-1616 G or its equivalent Clipsal / Legrand / Rittal / Schneider / ABB make only. The Junction box shall be fire retardant and self-extinguishing. The gasket material shall be polyurethane and the gasket shall be internally embedded. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer in Charge of work. |
| 30 | S/E of M.S. bracket (‘L’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of Fastener etc. for erection of metal halide flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job. |
| 31 | S/E of M.S. bracket (‘H’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of Fastener etc. for erection of metal halide flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job. |
| 32 | Supply and Laying of following XLPE insulated and PVC sheathed, armored, aluminum conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid on surface as required at site. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 33 | Size 10 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 34 | Supply and Laying of following XLPE insulated and PVC sheathed, armored, aluminum conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing trench/ DWC/RCC/HUME pipe as required at site. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 35 | Size 10 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 36 | Size 16 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 37 | Size 35 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 38 | Supply and erection of Sheet steel enclosure for TPN. The job includes cost of labour, making hole and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. |
| 39 | Supplying, Installation, Testing and Commissioning of 5 Meter height MS decorative type steel tubular pole suitable for installation of street light fixture, duly primed and painted. The pole shall be painted with MRF Poly urethane paint of approved colour. The bottom and middle embellishment are cast in iron and upper ring are cast in aluminum, fixed to the column by grub screw. The column shall be provided with inbuilt loop box, earth stud with 4 way 25 Amp heavy duty connector, 1 No. SP MCB and shall have matching flush door, fabricated & painted complete with S/F 16mm dia. 600mm long hot dip galvanized L-type Anchor bolts, plastering the same with fine sand and having horizontal top surface without any slope including two coats of trump exterior paint complete as required. The job also include the cost of supply & erection of decorative ornamental bracket on the top of pole as required to complete the job to the entire satisfaction of engineer in charge. |
| 40 | The pole shall be divided in two sections: |
| 41 | Top:- Dia. 75mm. Length 4000mm (3.2mm thick) or better. |
| 42 | Bottom:- Dia. 114mm. Length 1000mm (4.0mm thick) or better. |
| 43 | Base Plate:- 300 mm x 300 mm x 12 mm thick duly welded to column |
| 44 | Make of Decorative Pole: - K-Lite / Keselec / Bajaj / Homedec / Mayfair / Twinkle only. |
| 45 | Foundation for 5 Meter Long Decorative Pole:-Design & Casting of foundation with M20 cement Concrete & Steel Reinforcement suitable for installation of 5 Meter long decorative Pole. |
| 46 | DSR Item NO. 2.8.1 (Civil Work)Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. |
| 47 | All kinds of soil (Size 0.60 m x 0.60 m x 0.80 m = 0.288 Cum) 0.228 x 6 Nos. =1.368 Cum |
| 48 | DSR Item No. 5.22.6 (Civil Work)Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 49 | Thermo mechanically treated bars of grade Fe 500 D or more:-i. Vertical Bar 8 mm dia = 4 nos. x 0.70 = 2.80 r.mtr. @ 0.39 kg per mtr. = 1.09 Kgii. Horizontal Ring 6 mm dia = 4 nos. x 2.00= 8.00 r. mtr. @ 0.22 kg per mtr.= 1.76KgTotal (1.09 + 1.76 = 2.85Kg + 5% wastage = 2.99 Kg) 2.99 Kg x 6 Nos. = 17.94 Kg |
| 50 | DSR Item No. 5.2 (Civil Work)Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 51 | 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size):- Size 0.50 x 0.50 x 0.70 = 0.175 Cum0.175 Cum x 6 Nos. = 1.05 Cum |
| 52 | DSR Item No. 5.9.1 (Civil Work)Centering and shuttering including strutting, propping etc. and removal of form for : |
| 53 | Foundations, footings, bases of columns, etc. for mass concrete size 4 x (0.70 x 0.50) = 1.40 Sq. Mtr. 1.40 Sq. Mtr. x 6 Nos. = 8.4Sq. Mtr. |
| 54 | Dismantling and re-erection of existing pole along with fitting and bracket safely from one site to another site after dismantling the pole. The existing pole and muff shall be erected 1.25 Mtr. below ground level after digging the pit of size 12”. The job includes cost of crane charges and dismantling of incoming and outgoing connection etc. The job includes the cost of labour, throwing of malba into dumping ground and other petty material required to complete the job to the entire satisfaction of Engineer-in-charge of the work. |
| 55 | Supply and Erection of Cement Collar and Jn. Box at the base of the pole with the detailed specification as given below.: |
| 56 | Jn. Box Construction: |
| 57 | Supply and fixing of OEM made Junction box IP 66/67 made out of Polycarbonate with Glass fiber reinforced of size 205 x 255 x 112 (mm) (minimum) with 5 nos. OEM made connectors/terminal blocks. The Jn. Box and connectors/terminal blocks should be supplies by OEM. The terminal blocks/connectors should be of Hensel/Wago/Elmax/Siemens make only and Junction box shall be of Hensel make KF-2525 G or its equivalent Clipsal/Legrand/Schneider/ABB make only. The junction box shall be fire retardant and self-extinguishing. The gasket materal shall be polyurethane and the gasket shall be internally embedded. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge of work. |
| 58 | Cement Collar: |
| 59 | The box shall be enclosed in a cement collar made from cement concrete 1:2:4 and outside dia. 16”. |
| 60 | The collar shall be embedded in the ground upto 6” shall stand 9” above ground shall have 12” high MS box and 6” top over the box. |
| 61 | The collar shall be plastered, properly finished and painted with 2 coats of snowcem of superior quality to complete the job including new thimbles & making connections. |
| 62 | The item includes other petty material to complete the job. |
| 63 | The job includes all labour and petty material required to complete the job to the entire satisfaction of the E.I.C. of the work. Please Enable Macros to View BoQ information |