| 1 | Dismantling the exsinting demaged plain cement concrete in any ratio of clearing away and carefully stacking materials useful for re-use for any thickness using necessary equipments and machinaries including cost of all charges etc., completed |
| 2 | Dismantling the exsinting demaged brick wall in any ratio of clearing away and carefully stacking materials useful for re-use for any thickness using necessary equipments and machinaries including cost of all charges etc., completed |
| 3 | Dismantling floor tiles floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabsclearing away and carefully stacking materials useful for re-use for any thickness using necessary equipments and machinaries including cost of all charges etc., completed |
| 4 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 5 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 6 | Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 7 | Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification |
| 8 | Paving the floor with kota stone slab of size 300 x 300 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. |
| 9 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 10 | Wiring with 2x4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box in flush with wall with 3 mm thick hylum sheet for 15A3 pin non inter locking flush type CS plug with painting suitable colour with continuous earth wire connection of 4 sq.mm copper wire for open power plug point (SD 14) |
| 11 | Wiring with 2x1.5 sq.mm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5AFT switch inflush with wall covered with hylum sheet of 3 mm thick with painting of suitable colour for open PVC light / fan point (for electronic regulator) (5points per coil) (SD 22) |
| 12 | Supply and Fixing of 20W 4 Feet LED Fitting with LED of approved quality and make including all cost of materials, transportation, labour charges etc.,complete. |
| 13 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 14 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., (1000 L) |
| 15 | Repair and maintenance of CCTV Cp ip 2mb 10 camera NVR 16ch 2nd sata 4tb hard disk Rj45 jack 20 200PO gigbyte full Dlink outdoor cable 200m 1200010 camera box. Modem 5g modem dlink. Installation charge. Camera with Specification of Dahua- Analog High Definition camera, outdoor-25/30 fps@720P,1/2.9\\" 1 Megapixel CMOS, 50m IR,ICR, 6mm Lens optional, IR Bullet Dahua - Channel - AHD, High Video Quality on HD 1080N, Transmit Video Signal, audio signal & Dual way data communication signal over one coaxial cable, HD Video transmission without Video quality loss & delay, extremely, long transmission distance (300), as directed by Departmental Executive Engineer. |
| 16 | Repair and maintenance of Refridgerator which include all labour,material,etc..,as per standard specification directed by the departmental officers. |
| 17 | Repair and maintenance of RO system which include all labour,material,etc..,as per standard specification directed by the departmental officers. |
| 18 | Repair and maintenance of Stemar which include all labour,material,etc..,as per standard specification directed by the departmental officers. Please Enable Macros to View BoQ information |