| 1 | Shifting of solar security light fitting from one location to another location not more than 2 Km carefully with the help of tractor / Crane including all towing arrangement and taking out all connections, earthing of defective parts of solar street light and connecting carefully all connection including PCC , painting of pole as required at site and as directed by Engr-in-Charge. |
| 2 | Charger with PCB Controller suitable as per existing make complete all as specified. |
| 3 | All In One Solar Street Light 30 Watt with built in Mono Crystalline Panel, Lithium Ferro Phospate(LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor including taking down old unservicable light complete all as specified. |
| 4 | All In One Solar Street Light 25 Watt with built in Mono Crystalline Panel, Lithium Ferro Phospate(LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor including taking down old unservicable light complete all as specified. |
| 5 | All In One Solar Street Light 20 Watt with built in Mono Crystalline Panel, Lithium Ferro Phospate(LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor including taking down old unservicable light complete all as specified. |
| 6 | 30W solar LED street light luminaire with inbuilt lithium battery IP 65 producted complete with driver controller and mounting arrangement for pole installation complete all as specified and directed |
| 7 | Traffic LED Lights AC Complete with including taking down old Defective traffic light fitting of any capacity all as per specified |
| 8 | Traffic LED Lights DC Complete with including taking down old Defective traffic light fitting of any capacity all as per specified |
| 9 | Painting to existing Solar street light/solar traffic light poles, 6m long including angle iron support, bracing, clamps etc with two coats of aluminium paint on exposed surfaces complete all as specified and directed |
| 10 | Plain cement concrete M-10, 1:3:6 nominal mix, type C-1 using 20mm graded crushed stone aggregate for mass filling of pole , complete all as specified. |
| 11 | 6m aluminium alloy pole with clamps,nuts and bolts for fixing light fitting and suitable thickness Base plate complete all as specified & directed. |
| 12 | S&F Solar PV panel of capacity 90 WP suitable for 30 Watt light fitting complete all as specified & directed. |
| 13 | Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified. |
| 14 | Removal of excavated material to be distance n.exc 50M and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified. |
| 15 | Opening,dismantaling and taking down for replacement of undermentioned unserviceable spare parts of mechanical laundry plant complete servicing with testing at user site all as specified and directed by Engr- in-Charge. |
| 16 | Replacement of Digital temperature controller select type TC-203 |
| 17 | Replacement of Timer 6 pole 220V for clock wise & anticlock wise rotation |
| 18 | Replacement of 3 Pole Power contactor ,415V,100 Amp |
| 19 | Replacement of MCCB 80 Amp C Curve, 4 pole, 415 V 50 Hz 10 KA |
| 20 | Replacement of Rubber Gasket for front locking door |
| 21 | Opening,dismentaling and taking down for replacement of undermentioned unserviceable spare parts of machanical laundry for dryer plant all as specified following :- |
| 22 | Replacement of Shaft bearing size 1 feet long & dia 40mm |
| 23 | Replacement of Bearing bush for drier with complete kit |
| 24 | Replacement of Rubber gasket round type for front locking door. |
| 25 | Replacement of Ball bearing 6207 |
| 26 | Replacement of Pulley Belt A57, 1408 |
| 27 | Replacement of Pulley Belt B70, 1778 |
| 28 | Replacement of Pulley Belt A70, 1821 |
| 29 | Replacement of Pulley Belt A90, 2285 |
| 30 | Replacement of Blower heating element 3 KW for dryer |
| 31 | Replacement of Rubber bush |
| 32 | Butterfly valve |
| 33 | M&L for properly cleaning Solar PV panels & checking all electrical connections of solar plant 10 KW capacity complete all as specified. |
| 34 | S&F all in one solar pathway light complete with solar panel,LED luminaire,rechargeable battery charger controller,pole/spike and all necessary accessories suitable for outdoor garden/pathway lighting. Including installation, testing and commissioning all as specified directed. |
| 35 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm, 2 core for connection of solar light to PCB and battery complete all as specified and directed by Engr-in-Charge |
| 36 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sqmm, 2 Core nominal cross section in service connections, including taking down old wire complete all as specified. |
| 37 | Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information |