| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge. |
| 3 | Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge. |
| 4 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge. |
| 5 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. |
| 6 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge. |
| 7 | Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 75mm outer dia 63mm bore as per IS 16205 part 24 cable protection including all fitting as required complete all as specified & directed by Engineer-in-Charge. |
| 8 | Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 63mm outer dia 50mm bore as per IS 16205 part 24 cable protection including all fitting as required complete all as specified & directed by Engineer-in-Charge. |
| 9 | Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 40mm outer dia 32mm bore as per IS 16205 part 24 cable protection including all fitting as required complete all as specified & directed by Engineer-in-Charge. |
| 10 | Taking out LT UG cable of any size/any core as directed by engr in charge |
| 11 | Supply, laying, test and commissioning LT UG , XLPE insulated, armoured heavy duty, 1100V grade of electric cable size 10 Sqmm 4 core with aluminium conductor, served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs, bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning, Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items. |
| 12 | All as per item No 11.00 above but of size 16 Sqmm 4 Core |
| 13 | All as per item No 11.00 above but of size 35 Sqmm 3.5 Core |
| 14 | All as per item No 11.00 above but of size 50 Sqmm 3.5 Core |
| 15 | Relaying of old retrieved servicable LT UG cable of any size /any core omplete all as specified and directed by Engineer-in-charge. |
| 16 | S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge. |
| 17 | Surface dressing n exc 15 cm deep and getting out in soft/ disintegrated rock/any type of soil complete all as specified & directed by Engineer-in-charge. |
| 18 | Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust, etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior, synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc complete all as specified and directed by the Engineer-in-Charge. |
| 19 | Supply And Fixing in repair Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10% , Both Fixture And Drivre Must Have ptted type and Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements) including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Crompton cat no TRP-409-60-57-SL-GL-NSG or equivalent in Appx 'C' list of makes. |
| 20 | S&F galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings and including taking down existing bracket of any description complete all as specified and directed by Engineer-in-charge. |
| 21 | Supply and Fixing of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and including taking down old existing unserviceable junction box complete all as specified and directed by the Engineer-in-Charge. |
| 22 | Supply and fixing iof PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core including diconnected & taking down old existing unserviceable cable complete all as specified and directed by the Engineer-in-Charge. |
| 23 | S&F nature switch (using infrared sensor technology) based automatic street light control panel. The panel should be enough to take three phase load of 12 kw nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 12 KW with 3 nos contractor, 3 nos Incoming MCBs of 40 Amps and outgoing MCBs of 40 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof, Electric shock proof, Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor manual or auto operation including taking down existing nature switch of any description complete all as specified and directed by the Engineer-in-charge. |
| 24 | Material and labour for cutting the existing bituminious road / hard standing to size not exceeding 45 CM wide and depth not less than 45 cm for passing UG cable through GI pipe and making good the good distrubed surface and filled excavated material and 200 mm depth with plane cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate complete all as specified and directed by the Engineer-in-charge. |
| 25 | Supply and fixing MCB, TPN 40 to 100 Amp, 415V 10KA 'B' curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity in the DB/panel box/ feeder box complete with connection testing and commissioning including dismantling existing MCB complete all as specified and directed by Engineer-in-charge. |
| 26 | S&F in repair circular top of 80mm GI pipe fix with welding (height of pole 9 mtr etc complete all as specified & directed by Engineer-in-charge. |
| 27 | M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified & directed by Engineer-in-charge. |
| 28 | S&F in repair solar street light of 40 watt all in one FRP/ Aluminium extruded Lithium based energy efficient Integrated with polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 35-40 WP mono crystalline, Lithium battery 12.8 Volt, 18-24 Ah LiFeP04, Min Lux level >3000 Lumens, MPPT Charger with inbuit BMS Technology, PIR motion sensor system at 30% start dimming brightness glow to 100% for 30 second upon motion detection High brightness luminous efficiency W-LED (135-180 Im/Watt), life span of of LED >50,000 Hrs, protection lamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic fix motion dimming function with PIR motion sensor, Dusk to dawn operation, working temp : (-10 C) to (+) 55 C, humidity range 0-95%, with adjustable MS Clamp suitable for existing pole/wall mounting, low votage indication, charging indication with bty over charge protcetion, Bty deep discharge protection, No load/Open load protection etc complaint complete all as specified and directed by Engineer-in-charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS, IP65/ 66 and IKO8. |
| 29 | S&F steel water tubing 80 mm bore, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge. (each length of pipe 6mtr/20 feet) |
| 30 | M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work complete all as specified and directed by Engineer-in-charge. |
| 31 | M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply and, fixing fabricate structural mild steel RS joist, channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed by the Engineer-in-charge. Please Enable Macros to View BoQ information |