| Sl. No. | Item Description |
| 1 | Civil work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soilDSR2023/2.6.1 |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.DSR2023/2.27 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR2023/4.1.8 |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cumDSR2023/5.33.1.1 |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or moreDSR2023/5.22.6 |
| 7 | Centering and shuttering including strutting, propping etc. And removal of form for :Foundations, footings, bases of columns, etc. for mass concreteDSR2023/5.9.1 |
| 8 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesDSR2023/10.16.1 |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new workDSR2023/13.61.1 |
| 10 | Supply of 30 mm thick Sandwich Roof PUF Panels with 0.50mm thick PPGI Top Hi- Rib Profile Sheet and 0.50mm thick Bottom Linear Sheets & 40 +2 Kg/M³ density of PUF.MR |
| 11 | Supply of 40mm thick Wall PUF Panels with 0.50 mm thick Top & Bottom PPGI Linear Profile Sheets and 40mm thick Puf with 40+2Kg/M³density of PUF.MR |
| 12 | Fixing of PUF Panels with all required fixing accessories Tools and Tackels, GI Self Drilling Screws with inbuilt EPDM Rubber Gasket.MR |
| 13 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m²DSR2023/12.1.1 |
| 14 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m²DSR2023/12.7.1 |
| 15 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sach and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm foe series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimension, EPDm gasket , hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing haedware and drainage of water etc.After Fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof sillicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC Profiles to be as per design approved by Engineer-inCharge. Wire mesh/Glazing of plain/toughened/ laminated /double glass unit with / without high performance coatings as per design requirements and conforming to IS :3548 & IS : 16231 shall be paid separately. Notes:- Structural design proof cheacked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed >45 m/Sec as per IS 875 - Part 3. (ii) Sites with structure height more than 20m for all wind speeds.Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).DSR2023/9.147.A4.2 |
| 16 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)DSR2023/21.3.1 |
| 17 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sidesDSR2023/10.29.2 |
| 18 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top coverDSR2023/10.6.1 |
| 19 | Providing and fixing ball bearing for rolling shutters.DSR2023/10.7 |
| 20 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).DSR2023/10.9 |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)DSR2023/6.1.2 |
| 22 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)DSR2023/13.4.2 |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.DSR2023/13.80 |
| 24 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)DSR2023/13.47.1 |
| 25 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.DSR2023/11.4 |
| 26 | Supply and fixing of wonder floor vinayl sports flooring 6.5 mm thick complete in all respectMR |
| 27 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.DSR2023/4.17 |
| 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameterDSR2023/12.41.2 |
| 29 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler 110 mmDSR2023/12.42.1.2 |
| 30 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° x110 mm bendDSR2023/12.42.5.2 |
| 31 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm ShoeDSR2023/12.42.6.2 |
| 32 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mmDSR2023/12.43.2 |
| 33 | Badminton net,, nylonSR |
| 34 | PoleSR |
| 35 | Providing & Fixing of Stainless Steel Multi-seater Bench/Chair (3 individual Seats attached in one frame, with armrest & backrest), overall seating width approx. 1500 mm, entirely from SS 304 grade tubular section and slats/perforated sheet, with ergonomically designed backrest and side arm supports, polished/brushed finish, weather resistant, suitable for outdoor/indoor use in gardens/parks/government premises/waiting area, complete in all respects as per direction of Engineer-in-ChargeMR |
| 36 | Civil work (Rest room & Toilet) |
| 37 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soilDSR2023/2.6.1 |
| 38 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.DSR2023/2.27 |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR2023/4.1.8 |
| 40 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cumDSR2023/5.33.1.1 |
| 41 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or moreDSR2023/5.22.6 |
| 42 | Centering and shuttering including strutting, propping etc. And removal of form for :Foundations, footings, bases of columns, etc. for mass concreteDSR2023/5.9.1 |
| 43 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesDSR2023/10.16.1 |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new workDSR2023/13.61.1 |
| 45 | Supply of 30 mm thick Sandwich Roof PUF Panels with 0.50mm thick PPGI Top Hi- Rib Profile Sheet and 0.50mm thick Bottom Linear Sheets & 40 +2 Kg/M³ density of PUF.MR |
| 46 | Supply of 40mm thick Wall PUF Panels with 0.50 mm thick Top & Bottom PPGI Linear Profile Sheets and 40mm thick Puf with 40+2Kg/M³density of PUF.MR |
| 47 | Fixing of PUF Panels with all required fixing accessories Tools and Tackels, GI Self Drilling Screws with inbuilt EPDM Rubber Gasket.MR |
| 48 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m²DSR2023/12.1.1 |
| 49 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m²DSR2023/12.7.1 |
| 50 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sach and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm foe series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimension, EPDm gasket , hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing haedware and drainage of water etc.After Fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof sillicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC Profiles to be as per design approved by Engineer-inCharge. Wire mesh/Glazing of plain/toughened/ laminated /double glass unit with / without high performance coatings as per design requirements and conforming to IS :3548 & IS : 16231 shall be paid separately. Notes:- Structural design proof cheacked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed >45 m/Sec as per IS 875 - Part 3. (ii) Sites with structure height more than 20m for all wind speeds.Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).DSR2023/9.147.A4.2 |
| 51 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)DSR2023/21.3.1 |
| 52 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sidesDSR2023/10.29.2 |
| 53 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)DSR2023/6.1.2 |
| 54 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)DSR2023/13.4.2 |
| 55 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.DSR2023/13.80 |
| 56 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)DSR2023/13.47.1 |
| 57 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Double Charge Size of Tile 600X600 mmDSR2023/11.41.2 |
| 58 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.DSR2023/11.37A |
| 59 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screwsDSR2023/9.20.2 |
| 60 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).DSR2023/9.23 |
| 61 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.5 mm thickDSR2023/9.127.1 |
| 62 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mmDSR2023/9.96.1 |
| 63 | Providing and fixing aluminium tower bolts, ISI marked, powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour or shade, with necessary screws etc.complete : 250x10 mm.DSR2023/9.97.2 |
| 64 | Providing and fixing aluminium handles, ISI marked, powder coated (minimum thickness of powder coating 50 micron) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm.DSR2023/9.100.1 |
| 65 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopperDSR2023/9.101.2 |
| 66 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in charge.8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.DSR2023/11.4 |
| 67 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.DSR2023/4.17 |
| 68 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameterDSR2023/12.41.2 |
| 69 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler 110 mmDSR2023/12.42.1.2 |
| 70 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° x110 mm bendDSR2023/12.42.5.2 |
| 71 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm ShoeDSR2023/12.42.6.2 |
| 72 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mmDSR2023/12.43.2 |
| 73 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.DSR2023/17.78 |
| 74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapDSR2023/17.7.2 |
| 75 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm diaDSR2023/17.28.1.1 |
| 76 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.DSR2023/17.31 |
| 77 | Providing and fixing unplasticised PVC connection pipe with brass unions.45 cm length15 mm nominal boreDSR2023/18.21.2.1 |
| 78 | Providing and fixing Health faucet with white side spray, metal hose in polished chrome with flexible tube upto 1 metre long with S.S. triangular plate to European & Wall mount type W.C. of quality and make as approved by Engineer - in- charge. (K-26474IN-ER-0 kohler/Roca/American standard)MR |
| 79 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal boreDSR2023/18.53.1 |
| 80 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.DSR2023/17.71 |
| 81 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.DSR2023/17.73.1 |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall15mm dia nominal boreDSR2023/18.7.1 |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall20mm dia nominal boreDSR2023/18.7.2 |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall25mm dia nominal boreDSR2023/18.7.3 |
| 85 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal boreDSR2023/18.17.1 |
| 86 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal boreDSR2023/18.49.1 |
| 87 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.( K-26474IN-ER-0 kohler)DSR2023/17.80 |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankDSR2023/18.48 |
| 89 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With common burnt clay FPS (non modular) bricks of class designation 7.5DSR2023/19.7.1.1 |
| 90 | Electrical Work |
| 91 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group CDSR2022/1.10.3 |
| 92 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.DSR2022/1.11 |
| 93 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmDSR2022/1.21 |
| 94 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switchDSR2022/1.21.1 |
| 95 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.DSR2022/1.31 |
| 96 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.DSR2022/1.25 |
| 97 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)DSR2022/1.27.1 |
| 98 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3 module with GI box(100mmx75mm)DSR2022/1.27.2 |
| 99 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 module with GI box(125mmx75mm)DSR2022/1.27.3 |
| 100 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 module with GI box(200mmx75mm)DSR2022/1.27.4 |
| 101 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 module with GI box(125mmx125mm)DSR2022/1.27.5 |
| 102 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required.DSR2022/1.32 |
| 103 | Supply and fixing of ceiling fanMR |
| 104 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireDSR2022/1.14 |
| 105 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (circuit for Powe point looping )DSR2022/1.14.2 |
| 106 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (Submain for DB)DSR2022/1.14.5 |
| 107 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wireDSR2022/1.14.6 |
| 108 | Supply and fixing of recess/Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver pleasing aesthetic look. Complete in all respectSOR2022/1401 |
| 109 | Supply and fixing of LED Street light Fitting having die castaluminium body and diffuser with driver set suitable for 110 to130 Watt. Confirming to IP 65 and above Protection completein all respect.SOR2022/1424 |
| 110 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look.SOR2022/1402 |
| 111 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light complete including tube etc on surface complete in all respect. CAT-AAASOR2022/1413 |
| 112 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double doorDSR2022/2.4.3 |
| 113 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleDSR2022/2.10.1 |
| 114 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double poleDSR2022/2.10.3 |
| 115 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutralDSR2022/2.10.5 |
| 116 | S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.SOR2022/394 |
| 117 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.DSR2022/5.4 |
| 118 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.DSR2022/5.1.5 |
| 119 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the 4CORE X 16 SQMM AL.AR.XLPE CableSOR2022/501(i) |
| 120 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument.chamber etc. complete in all respects. The instrument chamber shall be.separate and shall comprise of flush type ammeter, voltmerer, selector.switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as perIS8623 istulate with heat shrink sleeving and mountend on non hygroscopic.supports such as CMC/DMC support with deteachable side covers and shall.be suitable for extension on the sides. The switches shall be complete with.suitable cable end boxes, reverse entery boxes in case of pedestaal type,.cable sockets, compression glands and indicating lamp on incoming etc..The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided withampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimumthickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B--100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.SOR2022/802(c) |
| 121 | S&F of 0.5 Amp to 5 Amp. 4 pole MCB (10 KA) C Curve CAT-A, these materials to be install in above panelSOR2022/2018 |
| 122 | S&F of 0.5 Amp. to 5 Amp. DP MCB (10 KA) C Curve CAT-A, these materials to be install in above panelSOR2022/1008 |
| 123 | SITC of 2 ton split AC including 2 years mentainence Power Supply: 230V, 50 Hz, single phase. Vendor should supply suitable rating external voltage stabilizer even if the AC is capable of operating with wide voltage range. Piping: 6 metres each of the insulated copper refrigerant pipings(suction and return line), 6 meters of eleBtrical cable and 6 meters of PVC drain piping with each AC system. Accessories: Mounting bracket for indoor unit, Heavy duty Stand for installing outdoor condenser unit on the roof or on the wall as required with serrated anti-vibration pads. Power and control cables of copper Warranty: Minimum 1 year on the whole machine and minimum 5 years on the compressor from the date of satisfactory installation, commissioning and acceptance of the AC unit Makes: Carrier/ Voltas /Blue star/ LG/Daikin/Hitachi/Mitsubishi/Panasonic /Samsung/HavellsMR |
| 124 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 150 Watt. Confirming to IP 66 protection completein all respect.CAT-AAASOR2022/1454 |
| 125 | Supply, installation, testing and commissioning of factory-wired integral LED street light luminaire suitable for 30W to 36W, with-die-cast-aluminium housing, IP65 protection, controlled by solar system.-Backup: Minimum 12 hours autonomy per day. Warranty: 3 years comprehensive warranty on complete system including LED, battery, solar panel and controller.Components included: 3 meter MS pole with base plate & foundation bolts, solar PV panel of suitable rating, LiFePO4/Lithium battery with weatherproof enclosure, MPPT/PWM charge controller, interconnecting cables, junction box, earthing, and all accessories required for complete installation for Solar System. (excluding Foundation)MR Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail