| 1 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core X 25 sqmm size armoured cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make: Havells / KEI / R R Kabel / Polycab |
| 2 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ X 70 sqmm size armoured UG cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make Havells / KEI / R R Kabel / Polycab |
| 3 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ X 120 sqmm size armoured UG cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make : Havells / KEI / R R Kabel / Polycab |
| 4 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core X 25 sqmm size armoured cable in the existing RCC/ HUME/ METAL pipe as required.. Make: Havells / KEI / R R Kabel / Polycab |
| 5 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ X 70 sqmm size armoured UG cable in the existing RCC/ HUME/ METAL pipe as required. Make: Havells / KEI / R R Kabel / Polycab |
| 6 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3½ X 120 sqmm size armoured UG cable in the existing RCC/ HUME/ METAL pipe as required.. Make: Havells / KEI / R R Kabel / Polycab |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. i) upto 35 sq. mm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. ii) Above 35 sq. mm and upto 95 sq. mm |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. i) Upto 35 sq. mm |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. ii) Above 35 sq. mm and upto 95 sq. mm |
| 11 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 35 sq. mm |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ii) 3½ X 70 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. iIi) 3½ X 95 sq. mm |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.i) 3½ X 35 sq. mm (32mm) |
| 15 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.ii) 3½ X 70 sq. mm (38mm) |
| 16 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.iii) 3½ X 95 sq. mm (38mm) |
| 17 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.iv) 3½ X 240 sq. mm (62mm) |
| 18 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 19 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 20 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 21 | Supplying and laying of 40 mm size PVC pipe ISI marked along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. from pole coller to loop box to protect the cable and dismentaling and reconnectioning with fresh thimbling etc complete as required. |
| 22 | SITC of outdoor type feeder panel of 450mm depth made of 2mm thick CRCA sheet of required size suitable for 415 Volt, 3 phase, 50 hz power supply complete with hinged doors, having locking arrangement and providing detachable gland plate of thickness 3mm at the bottom, earth bar/ stud, cable alley, Aluminium busbar of suitable size as per CPWD norms as required. All sheet metall parts separately chemically treated with 7 tank treatment process and the panel shall be finished with powder coating in Siemens Grey shade RAL 7032 and supplied with suitable pedastal frame with 4 Nos 600mm long legs with suitable apron all around including priming and painting etc. The Panel Shall be embeded in 1:1.5:3 cement concrete foundation of required shape and size 30 cms below ground level including finishing etc as required as per direction of engg-in-charge. (Make of panel - CPRI approved only) (Drawing will be approved from department before fabrication). |
| 23 | Supply, Installation, Testing, and Commissioning (SITC) of 250 A rating, 4-Pole Manual Changeover Switch with open execution type, complete with operating handle kit and interconnections using suitable size aluminium bus bars, etc., as required per the directions of the Engineer-in-Charge. ( Old Material willretain by the contractor) Make : Legrand/ Schnieder / Siemens/ ABB/ L&T /C&S |
| 24 | Supply, Installation, Testing, and Commissioning (SITC) of 100 A Enclosed TPN Switch Disconnector Fuse Unit 100 A rating, Three Pole and Neutral (TPN) switch disconnector fuse unit with sheet steel enclosure, fixed in existing panel. Includes connections with suitable rating bus bar/copper wire and all associated accessories as required, complete as per the directions of the Engineer-in-Charge. (Old Material willretain by the contractor) Make : C&S/ Havells / Siemens/ ABB/ L&T |
| 25 | Supply, Installation, Testing, and Commissioning (SITC) of 63 A Enclosed TPN Switch Disconnector Fuse Unit 63 A rating, Three Pole and Neutral (TPN) switch disconnector fuse unit with sheet steel enclosure, fixed in existing panel. Includes connections with suitable rating bus bar/copper wire and all associated accessories as required, complete as per the directions of the Engineer-in-Charge. (Old Material will retain by the contractor) Make : C&S/ Havells / Siemens/ ABB/ L&T |
| 26 | Supply, Installation, Testing, and Commissioning (SITC) of 32 A TPN Switch Disconnector Fuse Unit having 32 A rating, Three Pole and Neutral (TPN) switch disconnector fuse unit with sheet steel enclosure, fixed in existing panel. Includes connections with suitable rating bus bar/copper wire and all associated accessories as required, complete as per the directions of the Engineer-in-Charge. (Old Material willretain by the contractor) Make : C&S/ Havells / Siemens/ ABB/ L&T |
| 27 | Supplying and fixing of 5 amp to 32 Amp rating 240 volts 'C' series MCB of single pole and neutral pole in the existing junction box complete with connection, testing and commissioning etc as required. Make: Havells/ Legrand / Schneider / L&T Please Enable Macros to View BoQ information |