| 1 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of ENGINE MODEL 4R-1040T, 35 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set ( NEW COLONY SUB STN) : - |
| 2 | FRONT GLASS WITH GUIDER |
| 3 | DOOR LOCK |
| 4 | PANEL BOARD COMPLETE SET REPALCEMENT . |
| 5 | AIR FILTER |
| 6 | MOBILE FILTER |
| 7 | DIESEL FILTER |
| 8 | FAN BELT |
| 9 | REPALCEMENT OF ELECTRICAL WIRING OF DG SET |
| 10 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 11 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 12 | BATTERY CHARGER SET FOR DG SET |
| 13 | FUEL PUMP INJECTOR & NOZZLE SERVICE with replacement of unserviceable parts |
| 14 | RADIATOR SERVICE with replacement of unserviceable parts |
| 15 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No EW-20 , 15 KVA OF MAKE- kIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set : - (RAIL COLONY PH) |
| 16 | MOBIL FILTER |
| 17 | DIESEL FILTER |
| 18 | AIR FILTER |
| 19 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 20 | DOOR LOCK |
| 21 | FAN BELT |
| 22 | ELECTRICAL WIRING REPALCEMENT OF DG SET COMPLETE |
| 23 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 24 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 25 | RADIATOR SERVICE with replacement of unserviceable parts |
| 26 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE |
| 27 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 28 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No 4R-1040T , 35 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set\(MED REGT PH) : - |
| 29 | DIESEL FILTER |
| 30 | AIR FILTER |
| 31 | MOBIL FILTER |
| 32 | FAN BELT |
| 33 | HOSE PIPE |
| 34 | FRONT GLASS WITH GUIDER |
| 35 | DOOR LOCK |
| 36 | PANEL BOARD COMPLETE REPALCEMENT |
| 37 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 38 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 39 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 40 | BATTERY CHARGER |
| 41 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 42 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 43 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE |
| 44 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No 4R-1040T , 63 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set ( EME WKSHOP PH): - |
| 45 | DIESEL FILTER |
| 46 | AIR FILTER |
| 47 | HOSE PIPE |
| 48 | MOBIL FILTER |
| 49 | FAN BELT |
| 50 | FRONT GLASS WITH GUIDER |
| 51 | DOOR LOCK |
| 52 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 53 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 54 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 55 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 56 | BATTERY CHARGER |
| 57 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 58 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 59 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE |
| 60 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No 4R 1040T , 63 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/replacement/maintenance works is required to be carried out on above mentioned DG Set ( DHARAMPORE PH): - |
| 61 | DIESEL FILTER |
| 62 | AIR FILTER |
| 63 | MOBIL FILTER |
| 64 | FAN BELT |
| 65 | HOSE PIPE |
| 66 | FRONT GLASS WITH GUIDER |
| 67 | DOOR LOCK |
| 68 | PANEL BOARD COMPLETE REPALCEMENT |
| 69 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 70 | ENGINE FULL SERVICEwith replacement of unserviceable part |
| 71 | ALTERNATOR SERVICEwith replacement of unserviceable part |
| 72 | BATTERY CHARGER |
| 73 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 74 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 75 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE |
| 76 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No RB33 SR1 , 30 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (15 WEU) : - |
| 77 | DIESEL FILTER |
| 78 | AIR FILTER |
| 79 | MOBIL FILTER |
| 80 | HOSE PIPE |
| 81 | FAN BELT |
| 82 | FRONT GLASS WITH GUIDER |
| 83 | DOOR LOCK |
| 84 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 85 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 86 | ENGINE FULL SERVICEwith replacement of unserviceable part |
| 87 | ALTERNATOR SERVICEwith replacement of unserviceable part |
| 88 | BATTERY CHARGER |
| 89 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 90 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 91 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE |
| 92 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No RB33 SR1 , 30 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (15 WEU) : - |
| 93 | DISEL FILTER |
| 94 | AIR FILTER |
| 95 | HOSE PIPE |
| 96 | MOBIL FILTER |
| 97 | FAN BELT |
| 98 | FRONT GLASS WITH GUIDER |
| 99 | DOOR LOCK |
| 100 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 101 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 102 | ENGINE FULL SERVICEwith replacement of unserviceable part |
| 103 | ALTERNATOR SERVICEwith replacement of unserviceable part |
| 104 | BATTERY CHARGER |
| 105 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 106 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETEwith replacement of unserviceable part |
| 107 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No RB33 SR1 , 15 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (DETT SIG) : - |
| 108 | DISEL FILTER |
| 109 | AIR FILTER |
| 110 | HOSE PIPE |
| 111 | MOBIL FILTER |
| 112 | FAN BELT |
| 113 | FRONT GLASS WITH GUIDER |
| 114 | DOOR LOCK |
| 115 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 116 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 117 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 118 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 119 | BATTERY CHARGER |
| 120 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 121 | SELF DYNAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 122 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETEwith replacement of unserviceable part |
| 123 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of 63 KVA OF MAKE- ASHOK LEYLAND for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (CEM) : - |
| 124 | DIESEL FILTER |
| 125 | AIR FILTER |
| 126 | MOBIL FILTER |
| 127 | FAN BELT |
| 128 | HOSE PIPE |
| 129 | FRONT GLASS WITH GUIDER |
| 130 | DOOR LOCK |
| 131 | REPAIR TO SENSOR & PANEL BOARD COMPLETE SET with replacement of unserviceable part |
| 132 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 133 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 134 | BATTERY CHARGER |
| 135 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 136 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETEwith replacement of unserviceable part |
| 137 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No 4R-1040T , 125 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (MAP PH) : - |
| 138 | DISEL FILTER |
| 139 | AIR FILTER |
| 140 | MOBIL FILTER |
| 141 | FAN BELT |
| 142 | HOSE PIPE |
| 143 | FRONT GLASS WITH GUIDER |
| 144 | DOOR LOCK |
| 145 | ENGINE FULL SERVICEwith replacement of unserviceable part |
| 146 | ALTERNATOR SERVICE with replacement of unserviceable part |
| 147 | REPAIR TO SENSOR and Panel board with replacement of unserviceable parts |
| 148 | BATTERY CHARGER |
| 149 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 150 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE with replacement of unserviceable part |
| 151 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of 5 KVA OF MAKE- EICHER for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (CMI ROOM): - |
| 152 | DIESEL FILTER |
| 153 | AIR FILTER |
| 154 | MOBIL FILTER |
| 155 | FAN BELT |
| 156 | HOSE PIPE |
| 157 | FRONT GLASS WITH GUIDER |
| 158 | DOOR LOCK |
| 159 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 160 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 161 | ENGINE FULL SERVICE with replacement of unserviceable part |
| 162 | ALTERNATOR SERVICE with replacement of unserviceable parts |
| 163 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 164 | SELF DIANAMO SERVICE COMPLETE with replacement of unserviceable parts |
| 165 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETEwith replacement of unserviceable part |
| 166 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of Model No 4R-1040T , 63 KVA OF MAKE- KIRLOSKAR for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set (CHARAPOLE PH) : - |
| 167 | DIESEL FILTER |
| 168 | AIR FILTER |
| 169 | MOBIL FILTER |
| 170 | FAN BELT |
| 171 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 172 | ELECTRICAL WIRING REPLACEMENT OF DG SET |
| 173 | ENGINE FULL SERVICE with replacement of unserviceable parts |
| 174 | ALTERNATOR SERVICEwith replacement of unserviceable parts |
| 175 | BATTERY CHARGER |
| 176 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable part |
| 177 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE with replacement of unserviceable part |
| 178 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for DG set of 125 KVA OF MAKE- GREAVES for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set ( 15 WEU AC PLANT) : - |
| 179 | DIESEL FILTER |
| 180 | AIR FILTER |
| 181 | MOBIL FILTER |
| 182 | HOSE PIPE |
| 183 | FAN BELT |
| 184 | DOOR LOCK |
| 185 | PANEL BOARD COMPLETE SET REPAIR AND REPALCEMENT OF UNSV PART. |
| 186 | ENGINE FULL SERVICE with replacement of unserviceable parts |
| 187 | ALTERNATOR SERVICE with replacement of unserviceable parts |
| 188 | BATTERY CHARGER |
| 189 | COMPLETE SERVICING OF RADIATOR with replacement of unserviceable parts |
| 190 | FUEL PUMP INJECTOR & NOZZAL SERVICING COMPLETE with replacement of unserviceable part.Note for item no 1 to 13. (A) Monthly inspection and preventive maintenance contractor shall provide qualified trained service engineer from authorised dealer to check and inspect routine maintenance as follows: (a) DG set B check (b) DG set maintenance /health checkup. (c)checking of Lube oil ,top up if required. (d)check oil filter and cleaning. (e)check air filter cleaned periodically with compressed air (f)check batteries and Top up with distilled water , (g)check functioning of alternator . ( h)check cooland level and top up (j)cheack for leak if any and shall be rectified . (k)Diagnosis of faults in engine and alternator and its rectification. (l)Rectification of minor fault shall be done within time 24 hours |
| 191 | Dismantling and taking down of perforated leaked damaged silenser and exhaust system & fixing with new silencer and exhaust system from engine to outside the DG canopy & make it leak proof for DG set of size upto and including 63KVA complete all as specified and directed:- |
| 192 | Repair, testing and commissioning to PT fuel pump for DG set of any capacity including replacement of all service kit complete all as specified and directed |
| 193 | M & L for Repair/ overhauling of self starting system of DG set of capacity upto 125 KVA including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity with necessary connections incluing testing and commissioing complete all as specified and as directed. |
| 194 | Replacement of hinges of door of DG set upto 125KVA capacity with required accessories all as specified and directed. |
| 195 | Shifting of DG set of any capacity from one location to another location as per site requirement all as specified and directed. Note:all T&P ,hydra crane charge shall be included in qouted rate. |
| 196 | Material and Labour for cleaning of Fuel tank of DG set of any capacity manually as well as mechanically and also using cleaning compound making tank neat and clean all as specified and directed. |
| 197 | Supply and fixing in repairs of thermostatic valve set of DG set of any capacity with all connected accessories as per sample complete all as specified and directed |
| 198 | Supply and fixing in repairs of water pump assembly and oil pump assembly of DG set of capacity upto 125 KVA with all connected accessories including pump repair Kit as per sample complete all as specified and directed |
| 199 | M&L for Painting of DG set any capacity as per existing colour by applying two coat of synthetic enamel paint heat resistant by spray painting after preparation of old paint surface cleaning and scrapping writing all DG set specification complete all as specified and directed |
| 200 | Renewal of battery cable leads of copper conductor of size 70 Sqmm single core PVC insulated multistranded and with lugs for the 12V upto180 AH battery of length 1.5 mtr from the batteries to the DG set as that of existing size and length complete all as specified and directed . |
| 201 | M&L for replacement or topping up of superior quality coolant suitable for DG set Engine cooling complete all as specified and directed. |
| 202 | Drain out the old used engine oil from the sump and cleaning the sump including supply and filling the same with new engine oil (20W -40 or 15W - 40) upto the required level complete all as specified and directed. |
| 203 | Dismantling/taking down and seggregating all Unserviceabale parts carefully with proper T&P for AMF Panel (Auto On Main Failure) DG set of 125 KVA OF MAKE- GREAVES for repair / replacement with new parts after carrying out all repair works including testing all as directed by Engr-in-Charge. The following repair/repalcement/maintenance works is required to be carried out on above mentioned DG Set ( 15 WEU AC PLANT) : - |
| 204 | Repalcement of 200 Amps MCCB, 4 pole, 36 KA complete |
| 205 | Repalcement of relay suitable for AMF panel of rating 125 KVA DG set |
| 206 | Repalcement of Contactor suitable for 125 KVA DG set, 415 Volts, AC, 50 HZ type complete |
| 207 | Replacement of On & Off push button (Red/Green) complete as per sample |
| 208 | Replacement of digital ammeter, voltmeter, selector switch for ammeter and voltmeter, MCB SP 6 Amps-03 Nos, LED indicator lights-03 Nos, CT's of rating 200/5 Amps-01 Set including complete internal wiring and testing all as specified |
| 209 | Supply and fixng LED All-In -One solar street light fitting 36 watts rating including galvanised steel pole in built in lithium ion battery, solar panel, charge controller with dusk down sensor complete including taking down completely old UNSV solar light fiiting all as specified and directed. |
| 210 | Renewal of Heavy duty battery 12 Volt 180 AH fabricated of special propylene container ready to use and factory charged and maintenance free with all connected accessories complete of mode MHD1800, FEXOMHD1800, 180 AH (20 Hour), with acid level indicator including depositing old one to MES store yard complete all as specified and directed. |
| 211 | Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) with new ones of the exising make of generator of capacity 63 KVA to 125 KVA, complete all as specified and directed. |
| 212 | Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) with new ones of the exising make of generator of capacity 15 KVA to 35 KVA, complete all as specified and directed. |
| 213 | Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps with side handle operated complete all as specified and as directed. |
| 214 | Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps with side handle operated complete all as specified and as directed. |
| 215 | Supply and fix of MCCB 4 pole 415 V ,160amps with breaking capacity 36KA complete all as specified and directed. |
| 216 | Supply and fix of MCCB 4 pole 415 V ,250amps with breaking capacity 36KA complete all as specified and directed. |
| 217 | M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr belwo ground levels with top edge of the earh plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6mm earth lead by means ofbolts, nuts, check nuts and washers of galvanised steel all as shown in electric plate No. of SSR Part-I connected to continuous earth wire on main switch board all as specifed or indicated and testing on completion. |
| 218 | Renewal of Heavy duty battery 12 Volt 90/100 AH fabricated of special propylene container ready to use and factory charged and maintenance free with all connected accessories complete of mode MHD1000, FEX0-MHD99 AH (20 Hour), with acid level indicator including depositing old one to MES store yard complete all as specified and directed.(Make-EXIDE EXPRESS/AMARON as approved) |
| 219 | Servicing and overhauling of RO Plant of 500 LPH capacity including neccessary minor work all as specified and directed. |
| 220 | Supply and fixing Micron filter Cartridge suitable for 500 LPH RO plant complete |
| 221 | Supply only Antiscalant chemical suitable RO system |
| 222 | Supply only Sodium bi carbonate |
| 223 | Replacement of RO control panel |
| 224 | Replacement of Rotameters |
| 225 | Dosing pump for RO plant |
| 226 | Supply and fixing RO membrane type 250 LPH discharge capacity suitable for 500 LPH RO plant complete including taking out old UNSV membrane of 250 LPH capacity complete all as specified and directed by EIC. |
| 227 | M&L for Replacement of sand and carbon FRP Vessel both with filtration media like pebbles ,carbon ,course sand etc for 500 L.P.H RO Plant including taking out old UNSV Vessel as per sample with fitting of all connected accessories required at site and complete testing, commissioning and installation of the plant all as specified and directed by Engr-in-Charge. |
| 228 | Replacement of RO plant complete pipe line of 500 LPH with all fitting as per sample all as specified and directed. |
| 229 | Serviceing and maintenance of solar water heater of capacity upto 300 ltrs FPC type cleaning tank and collector with acid and water including replacement of connector ,socket ,PVC pipe all as specified and directed.(Note:Job will be carried out on rooftop and existing system installed at a hieght of 25 m above the normal ground level,neccessary requirement of T & P for execution of work is deemed to be included in unit rate quoted) |
| 230 | taking down old unserviceable broken solar water heater flat plate collector of 100 Litre capacity from existing system installed at roof top (Approx 25 Mtr from normal groung level)by uncsrewing complete nuts,bolts and screws and removal of other filments/accessories like inlet and outlet water suply pipe lines,valves etc. . complete all as specisified and directed. (Note:Job will be carried out on rooftop and existing system installed at a hieght of 25 m above the normal ground level,neccessary requirement of T & P for execution of work is deemed to be included in unit rate quoted) Please Enable Macros to View BoQ information |
| 231 | taking down old unserviceable broken solar water heater flat plate collector of 100 Litre capacity from existing system installed at roof top (Approx 25 Mtr from normal groung level)by uncsrewing complete nuts,bolts and screws and removal of other filments/accessories like inlet and outlet water suply pipe lines,valves etc. . complete all as specisified and directed. (Note:Job will be carried out on rooftop and existing system installed at a hieght of 25 m above the normal ground level,neccessary requirement of T & P for execution of work is deemed to be included in unit rate quoted) Please Enable Macros to View BoQ information |