| 1 | Taking up or down any type GI / CI /DI / MS pipe 100 mm to 200 mm dia and connections complete all as specified and directed. |
| 2 | M & L for Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying pipe line and getting soft/loose soil complete all as specified and directed. |
| 3 | M & L for Returning , filling in including spreading, levelling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 4 | M & L for Removing excavated material (soils) to a distance not exceeding 50 m and depositing whare directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | M & L for Boring under Road / PCC by using manual tool for inserting, of Pipe line any size complete all as specified and as directed by the Engineer-In-Charge. |
| 6 | M & L for Cutting of existing RCC road/PCC/Tiles for pipe line and making good to the disturbed surfaces of floor from RCC including to match the existing type etc all as directed |
| 7 | M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for filling of road, including necessary form work finishing even and smooth complite all as specified and directed . |
| 8 | S&Fix in replacement of GI fittings such as and,reducer, nipple, socket,union with complete fittings as per reqd size all as specified & directed by Engr-in-charge. |
| 9 | Supply, laying,connecting and testing 150 mm bore, ductile iron pipes tyton joint class K- 9 suitable for including rubber joint in standard working length conforming to IS 8329 laid in trenches complete all as specified and directed. |
| 10 | Supply, laying,connecting and testing 100 mm bore, ductile iron pipes tyton joint class K- 9 suitable for including rubber joint in standard working length conforming to IS 8329 laid in trenches complete all as specified and directed. |
| 11 | M&L for Ductile special fitting such as bends,tapers.tee pieces(single and double branch) any type and angle/radius and straight connecting pieces but all end flanged complete all as specified and directed . |
| 12 | S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes 150mm dia as specified and directed |
| 13 | S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes 100mm dia as specified and directed |
| 14 | S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes 200mm dia as specified and directed |
| 15 | M&L for GI fittings for DI Pipe lines ISI marked VIZ bends, Flanges, washers, reducers, tees, elbows, sockets, dummy plugs, complete all as specified up to 100 mm bore pipe complete all as specified |
| 16 | Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. |
| 17 | M&L for laying bricks, sub class'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.. |
| 18 | Taking up or down any type GI MS pipe 25 to 80 mm dia and connections complete all as specified and directed. |
| 19 | S&F, Laying, 25mm GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed at site incl taking down the existing. |
| 20 | S&F, Laying, 32mm GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed. |
| 21 | S&F , Laying, 40mm GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed at site incl taking down the existing. |
| 22 | S&F , Laying, 50mm GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed at site incl taking down the existing. |
| 23 | S&F , Laying,80mm GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed at site incl taking down the existing. |
| 24 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core complete all as specified and directed. |
| 25 | M&L for all unserviseable material/items removing out of the sumps/pumps house and deposited to MES yard, cleaning and painting of the serviseable pumps/sumps installation name complete all as specified and directed. |
| 26 | Supply and fix in replacement of 32 MM 3-layer PP-R Polypropylenerandom copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusionwelded havingthermal stability forhot & cold water supply includingall PP-R plain threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.such as tee,socket ,albow,reducer etc for PPR Pipe water supply including all fitting and fixture reqd at site material as specified and directed by Enge -in-charge. |
| 27 | S& Fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 28 | S&Filling of p-greavel type of small naturally rounded rock typically sized between 3 to 10mm for borewell filtration cleaning & washing after filling of the borewell as per existing complete all specified & directed by Engr-in-charge. |
| 29 | M&L for Development of bore well with DTH air compressor of rating 630 CFM at 100 PSI after with 25% extra capacity pump by pumping muddy water as required The air compressor / higher capacity pump required for the development of the borewell by means of over pumping shall be arranged by the contractor at his own arrangement complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |