| 1 | S & F in repairs MCCB 650 Amp, 4 pole 50 KA with release adjustable thermal & fixed magnetic complete all as specified and as directed. |
| 2 | S & F in repairs MCCB 200 Amp, 4 pole 36 KA with release adjustable thermal & fixed magnetic complete all as specified and as directed. |
| 3 | S & F in repairs MCCB 400 Amp, 4 pole 36 KA with release adjustable thermal & fixed magnetic complete all as specified and as directed. |
| 4 | S & F in repairs MCCB 63 Amp, 4 pole 16 KA with release adjustable thermal & fixed magnetic complete all as specified and as directed. |
| 5 | S & F in repairs MCCB 100 Amp, 4 pole 25 KA with release adjustable thermal & fixed magnetic complete all as specified and as directed. |
| 6 | M&L in repair for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 7 | M&L in repair pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed. |
| 8 | M&L in repair for shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts of size 75mm height and 90mm dia size of strap 31x3mm and dia of bolts 12mm for working pressure 1100 volts grade complete all as specified and as directed. |
| 9 | M&L in repair for loop type insulator, vitreous porcelain white, brown or green large size with overall dimensions 90mmx140mm clearance of hole 25.5mm complete all as specified and as directed. |
| 10 | M&L in repair for stay assemby complete with accessories such as stay plate 230mmx230mmx6mm, stay rod 180cm long 16mm dia with nuts including GI bow, turn buckle etc. all as per electrical plate No. 01 of SSR Part-I 2009 (loop type insulator, stay strands, excavation, PCC will be measured & paid separately) complete all as specified and as directed. |
| 11 | M&L in repair for aluminium conductor steel reinforced (ACSR) of any size for OH line including stretching, binding with aluminium binding wire, jumpers, line taps etc complete all as specified. |
| 12 | Taking down old U/S XLPE cable any typer any size warn out all specified & directed by engr -in-charge. |
| 13 | supply & fixing in replacement of PVC float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 100mm bore complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and laying in repair of synthatic rubber insulated mats 2.5 mm thick for electrical purpose as per IS 15652. suitable for electrical shock saftey of size 2mx1m complete all as specified,Capacity-Three phase 11KVA. |
| 15 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2.0 Core complete all as specified and as directed. |
| 16 | Taking down existing non functional security/street light fittings from pole/wall/pipe of any type of LED fitting of any wattage for repairing by replacing of the street light including replacement/ unserviceable accessories like SPD,LED Driver etc & refixing the same with & including connecting cable of 3 core PVC sheathed cu wire conductor not less than 4 Sqmm from light fitting to cable loping box & tightening of brackets, clamp by nut, bolts and washer including testing complete all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule.(ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items.(iii) Any type of Ladder or arrangement for dismantling of light from pole/ veh shall be arranged by the contractor for S/L complaints. |
| 17 | Supply and fix in replacement of unserviceable Supply and fixing LED street light fitting 45 Watt230 V AC outdoor type with senser high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete. |
| 18 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 19 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 20 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete including making connection complete all as specified and as directed by Engr-In-Charge. |
| 21 | Supply and fixing new LED Flood light fitting 100 watts to be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Engr-In-Charge. |
| 22 | Supply and fixing new LED Flood light fitting 200 watts to be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Engr-In-Charge. |
| 23 | Supply and fixing new Extruded aluminium decorative luminaire for LED (Retrofit). is an ideal solution for Garden/pathways light of housing material powder coated Zn plated ERW MS tubular section , coloure temp cool white 6500K LED 15 watt complete including making connection complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply and fixing in replacement mounting bracket made out of medium grade GI tubing suitable size bent to shape including 02 Nos MS clamps, Nut bolts, washers etc all as directed by Engineer in charge. |
| 25 | S & F in replacement 15 W LED Street Light suitable for Solar Light complete all as specified and as directed by the Engineer-In-Charge. |
| 26 | S & F in replacement 35 W LED Street Light suitable for Solar Light complete all as specified and as directed by the Engineer-In-Charge. |
| 27 | S & F in repacement post top lantern led type 20 watt type light fitting (RUBY (CLEAR) - IP65 ) New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.including making connection complete all as specified and directed by Engr-in-Charge. |
| 28 | S & F Decorative gate light made up of high grade unbreakable Doom Only 6\\" to 15\\") polycarbonate material suitable for retrofit including LED Lamp 9W/10W Lamp B22 base.complete all as specified |
| 29 | S & F Decorative lyse décor square shade 18 watts black Metal Exterior gate light,garden Lamp, outdoor light durable long life water & Rust proof Metal holder type B22 (normal 2 pin type) size 18Lx18Wx28H .complete all as specified |
| 30 | S & F Varnet waterproof adjustable 5 to 10 watt outdoor garden LED Light aluminium die caste, rustproof lights for garden (colour as required) complete all as specified and directed. |
| 31 | Supply and fix in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0metres long) complete all as specified and as directed |
| 32 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm 2 Core complete all as specified and as directed. |
| 33 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4.0 Core complete all as specified and as directed. |
| 34 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4.0 Core complete all as specified and as directed. |
| 35 | Boring under Road / PCC by using manual tool for inserting PVC/GI pipe of 40mm size for protection of cable complete all as specified and as directed by the Engineer-In-Charge. |
| 36 | Trimming of trees all as along the LT line in such a way that there is clear distance of 3 meter between tree and electric line. The work will be executed to the entire satisfaction of Engr-In-Charge irrespective of the size of the tree branches etc complete all as specified and as directed. Note : (i) Tree branches etc will be left as itias the wood belongs to Cantt board/DEO and they will be responsible for the wood. (ii) Contractor will employ sufficient labour to complete the full one job with in about 15 days. (iii) Contractor will responsible for any type of accident while trimming the trees. (iv) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply, however full assistance will be provided by MES staff. |
| 37 | S&F in replacement lead acid power pack unit of capacity 12 volts 180 AH of DG Sets/inverter complete all as specified and diected by Engr-in-Charge. |
| 38 | M&L Preparation of old (exposed) painted surface of existing (410 SP-31 ) Steel tubler poles /strut including cross clamps etc complete and applying two coat of aluminium paint above band/straps and painting of band/strap with paint of colour red post office and black numbering of pole at a height 1.5 m above GL as per existing having 15mm wide of poles at a heigth 1.5 M above GL as per existing having 15 mm wide and 50 mm bolt letter compete all as specified and directed . |
| 39 | M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth complite all as specified and directed . |
| 40 | M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc in foundation filling completed all as directed by Engr-in-Charge. |
| 41 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose or any other type of soil for taking up or laying of cable all as specified and directed. |
| 42 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed. |
| 43 | Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified and as directed. |
| 44 | Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. |
| 45 | M&L for laying bricks, sub class'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed. |
| 46 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed 10 sqmm 2 core in service connections , one twin core cable circular complete all as specified and as directed by Engr-In-Chage. |
| 47 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed 6.0 sqmm 2 core in service connections suspended by insulating one twin core cable circular complete all as specified and as directed by Engr-In-Chage. |
| 48 | Supply and Fixing 1100 volts grade heavy duty cable PVC insulated cupper conductor, served with inner sheathing of PVC tape and overall PVC sheathed 2.5 sqmm 2 core in service connections complete all as specified and as directed by Engr-In-Chage. |
| 49 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate notless'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion |
| 50 | Supply & filling distilled water in batteries as required at various DG set installations all as specified and directed. |
| 51 | Maintenance/ servicing of different capacity of DG sets by carrying out check as per manfacturers maintenance chart : (Note:Engine Oil and patrs shall be measured and paid seperately under respective item.) |
| 52 | (a) DG set 30 KVA , Engine |
| 53 | (b) DG set 40 KVA, Engine. |
| 54 | (c) DG set 50 KVA, Engine. |
| 55 | (d) DG set 63 KVA, Engine. |
| 56 | S & Replacement of Auto Voltage Regulator complete with wire connection and connected to existing field coil, 24 Volt, DC for cap of DG set 30/40 KVA Make- Kirloskar / Cummins after taking out the unserviceable one complete all as specified and as directed. |
| 57 | S & Replacement of Auto Voltage Regulator complete with wire connection and connected to existing field coil, 24 Volt, DC for cap of DG set 63 KVA Make- Kirloskar after taking out the unserviceable one complete all as specified and as directed. |
| 58 | S & Replacement of alternator 24 Volt (for charging of battery) for 30 to 63 KVA DG Set Make Lucas after taking out the unserviceable one complete all as specified and as directed. |
| 59 | Taking down the u/s self starter and repairs with rewinding to self starter of capacity 12/ 24 Volt by taking out old burnt out copper winding wire with super enamelled copper wire same gauge including replacement of u/s pinion, bush, solenoid coil, carbon brushes & tension spring complete and the DG Sets and testing consider all as specified and directed. |
| 60 | Supply only air filter of DG set of Cummins/ kirloskar of Capacity 12.5 KVA |
| 61 | Supply only air filter of DG set of Cummins/ kirloskar of Capacity 30 KVA |
| 62 | Supply only air filter of DG set of Cummins/ kirloskar of Capacity 40 KVA |
| 63 | Supply only air filter of DG set of Cummins/ kirloskar of Capacity 50 KVA |
| 64 | Supply only air filter of DG set of Cummins/ kirloskar of Capacity 63 KVA |
| 65 | Supply only filling the Engine Oil 20w 40 suitable for DG set complete as specified and directed by Engineer in charge. |
| 66 | Supply only fuel filter of DG set of Cummins/ kirloskar of Capacity 30 KVA complete all as specified and as directed. |
| 67 | Supply only fuel filter of DG set of Cummins/ kirloskar of Capacity 40 KVA complete all as specified and as directed. |
| 68 | Supply only fuel filter of DG set of Cummins/ kirloskar of Capacity 63 KVA complete all as specified and as directed. |
| 69 | Supply only Lube oil filter of DG set of Cummins/ kirloskar of Capacity 12.5 complete all as specified and as directed. |
| 70 | Supply only Lube oil filter of DG set of Cummins/ kirloskar of Capacity 30 KVA complete all as specified and as directed. |
| 71 | Supply only Lube oil filter of DG set of Cummins/ kirloskar of Capacity 40 KVA complete all as specified and as directed. |
| 72 | Supply only Lube oil filter of DG set of Cummins/ kirloskar of Capacity 50 KVA complete all as specified and as directed. |
| 73 | S & F in replacement changerover Switch 200 Amp to be fixed to channel and as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Engr-In-Charge. |
| 74 | Supply and replacement of solenoid coil, 12/ 24 Volts , DC operated with lead and fixing clamps all as directed by Engr in Charge. |
| 75 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 63 KVA DG Set of make Kirloskar/ cummins all as specified and directed. |
| 76 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 40 KVA DG Set of make Kirloskar/ cummins all as specified and directed. |
| 77 | M&L for replacement of hose pipe set (water/ oil) complete with clamp and other fitting as required at site for 12.5 to 30 KVA DG Set of make Kirloskar/ cummins/ Atul Shakti all as specified and directed. |
| 78 | Supply and filling coolant for DG set as per DG set manufacturers recommendations all as specified. |
| 79 | M&L in replacement of DB for street light made out of pvc sheet, dust and vermin proof out door type duly painted of size 200 mm x 200 mm x 15 mm with arrangement of incoming and outgoing feeder with bus bar of suitable capacity for termination of line with single MCB SP, 230 V, 6-10 Amp 10 KA ( In accordance wth IS/IEC 60898-1) and arrangement for fixing cooper wire of size 2 x 1.5 Sqmm with 1 x 1.0 Sqmm earth wire in green color of FR PVC insulated copper conductor,from DB to light fitting complete including taking up of old UNSV DB complete all as specified and directed by Engr-in-Charge. |
| 80 | M&L in replacement solar lead acid power pack unit of capacity 12 volts 120 AH of with solar light arrange lock & key existing complete all as specified and diected by Engr-in-Charge. |
| 81 | S&F 32 mm bore dia light grade GI steel tubing with all fittings for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 82 | S&F 40 mm bore dia light grade GI steel tubing with all fittings for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 83 | S&F Danger notice plate of sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm all as specified and directed by Engr- in -charge. Please Enable Macros to View BoQ information |
| 84 | S&F Danger notice plate of sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm all as specified and directed by Engr- in -charge. Please Enable Macros to View BoQ information |