| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. (DSR No. 2.31) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR No. 4.1.) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR No. 4.1.2) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR No. 4.1.) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR No. 4.1.3) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR No. 4.1.) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR No. 4.1.8) |
| 6 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). (DSR No. 4.10) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR No. 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR No. 5.1.2) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). (DSR No. 5.3) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR No. 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR No. 5.9.5) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR No. 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR No. 5.9.6) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6/ 5.22.6.A) |
| 13 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections (DSR No. 5.30) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR No. 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR No. 6.4.2) |
| 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR No. 9.48) Fixed to steel windows by welding (DSR No. 9.48.1) |
| 18 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (DSR No. 10.1) |
| 19 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) |
| 20 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR No. 11.3)40 mm thick with 20 mm nominal size stone aggregate (DSR No. 11.3.1) |
| 21 | 12 mm cement plaster of mix : (DSR No. 13.4) 1:4 (1 cement: 4 coarse sand) (DSR No. 13.4.1) |
| 22 | 12 mm cement plaster of mix : (DSR No. 13.4) 1:6 (1 cement: 6 coarse sand) (DSR No. 13.4.2) |
| 23 | 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1) |
| 24 | 15 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2) |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade: (DSR No. 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR No. 13.46.1) |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (DSR No. 13.62.1) |
| 27 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR ) (DSR 13.88) |
| 28 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.1) With cement mortar 1:4 (1cement: 4 coarse sand) (DSR 14.1.2) |
| 29 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR ) (DSR 14.17) |
| 30 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR No. 15.3) |
| 31 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR ) (DSR 15.56) |
| 32 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60) |
| 33 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. (DSR No. 15.7) In cement mortar (DSR No. 15.7.4) |
| 34 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) |
| 35 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR ) (DSR 16.71) |
| 36 | S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (NSI Based on CSI No. 9.22) |
| 37 | Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work. (CSI No. 11.16) |
| 38 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR No. 16.53) Please Enable Macros to View BoQ information |