| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (DSR 2.8) All kinds of soil. (DSR 2.8.1) |
| 3 | Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. NSI Based on (DSR 2.25(a)) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) |
| 6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) |
| 9 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (DSR ) (DSR 4.10) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/ (DSR 5.22A.6) |
| 15 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections (DSR No. 5.30) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) |
| 19 | (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) |
| 21 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) |
| 22 | Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) |
| 23 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) |
| 24 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) |
| 25 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) |
| 26 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) |
| 27 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR ) (DSR 11.2) |
| 28 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) |
| 29 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) |
| 30 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR ) (DSR 11.27) |
| 31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR ) (DSR 11.37) |
| 32 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2) |
| 33 | 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) |
| 34 | Neat cement punning. (DSR ) (DSR 13.18) |
| 35 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR ) (DSR 13.21) |
| 36 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (DSR 13.41.1) |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) |
| 38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR ) (DSR 13.80) |
| 39 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour (DSR 13.81) Old work (one or more coats) (DSR 13.81.1) |
| 40 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR ) (DSR 13.91) |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) |
| 42 | Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) |
| 43 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) |
| 44 | Renewal of old putty of glass panes (length) (DSR ) (DSR 14.9) |
| 45 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR ) (DSR 14.79) |
| 46 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) |
| 47 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR ) (DSR 14.82) |
| 48 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) |
| 49 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) |
| 50 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) |
| 51 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR ) (DSR 15.52) |
| 52 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR ) (DSR 15.56) |
| 53 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR ) (DSR 15.60) |
| 54 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR ) (DSR 16.45) |
| 55 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) |
| 56 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) |
| 57 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) |
| 58 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR ) (DSR 17.7A) |
| 59 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) |
| 61 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) |
| 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) |
| 66 | Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) |
| 67 | Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) |
| 68 | Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) |
| 69 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR ) (DSR 18.48) |
| 70 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR ) (DSR 18.65) |
| 71 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) |
| 72 | Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) |
| 73 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) |
| 74 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) |
| 75 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) |
| 76 | Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.39) |
| 77 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia |
| 78 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 |
| 79 | S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) |
| 80 | Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work. (CSI No. 27.21b) as above but for 100 mm.PVC trap. |
| 81 | Providing and fixing CI GRATING 100 mm dia including all materials, labour cartage T&P etc.required for proper completion of the work. (CSI No. 27.25) |
| 82 | Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work. |
| 83 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR ) (DSR 9.83) |
| 84 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.1) With cement mortar 1:4 (1cement: 4 coarse sand) (DSR 14.1.2) |
| 85 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) |
| 86 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) Please Enable Macros to View BoQ information |