Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Sub Head No. 1 Public Health Services(Flooring and Dados) |
| 2 | Dismantling concrete Cement concrete plain 1:4:8 or 1:5:10 (Floor Tiles*0.1) |
| 3 | Cement concrete 1:4:8 with stone ballast 20mm gauge mixing by mechanical means using concrete mixer volumetric type (Floor Tiles*0.1) |
| 4 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregates to be laid below the topping using mechanical mixer for mixing of material |
| 5 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 6 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 7 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 8 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. (Floor Tiles + Wall tiles) |
| 9 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 11 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 12 | Carriage of Malba from site of work to dumping ground complete in all respects |
| 13 | Sub Head No. 1 a Internal Public Health Services |
| 14 | Cement concrete 1:2:4 |
| 15 | With stone ballast or shingle |
| 16 | mixing by manual means |
| 17 | Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.), painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 18 | 15 mm i/d |
| 19 | 20 mm i/d |
| 20 | 25 mm i/d |
| 21 | 50 mm i/d |
| 22 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 23 | 15 mm i/d G.I. Union |
| 24 | 20 mm i/d G.I. Union |
| 25 | 25 mm i/d G.I. Union |
| 26 | 50 mm i/d G.I. Union |
| 27 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 28 | 15mm i/d Brass Ball valves |
| 29 | 20mm i/d Brass Ball valves |
| 30 | 25mm i/d Brass Ball valves |
| 31 | 50mm i/d Brass Ball valves |
| 32 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 33 | Through wall 22.86 cm thick |
| 34 | Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. |
| 35 | 15mm internal diametre pipe line. |
| 36 | 20mm internal diametre pipe line. |
| 37 | 25mm internal diametre pipe line. |
| 38 | 50mm internal diametre pipe line. |
| 39 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 40 | Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect. |
| 41 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 42 | With C.P. Brass nut |
| 43 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 44 | Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm complete in all respect. |
| 45 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 46 | Providing and fixing partition for different type of urinals. |
| 47 | Toughned Glass Partition 8mm thickness size 450 x 900 mm C/S |
| 48 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 49 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 50 | Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 51 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 52 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in- charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 53 | Size 560mm x 450mm (Under counter oval) |
| 54 | Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) |
| 55 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge) |
| 56 | Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect. |
| 57 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-incharge) complete in all respect. |
| 58 | Providing & Fixing in postion CP Brass bath tub spout with wall flange of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 59 | Providing and Fixing in position Glass shower enclosure L shaped 8mm thick with chrome finish with sliding door and entry from the front of approved make (to the approval of Engineer- in-charge) complete in all respect. 1200x1000 x 1950mm |
| 60 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 61 | Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 62 | C.P. brass toilet paper holder |
| 63 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect |
| 64 | C.P. brass towel Rails size 15mm dia 610mm long |
| 65 | C.P brass towel ring |
| 66 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 67 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 68 | Size 600mmx450mm |
| 69 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 70 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 71 | C.P. Brass extension piece, 25mm long to 50mm long |
| 72 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 73 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 74 | C.P. brass Bib cock foam flow without flange |
| 75 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 76 | C.P.brass 15mm Concealed stop cock with flange. |
| 77 | C.P.brass 15mm Angle valve without flange |
| 78 | Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. brass liquid soap container |
| 79 | Providing and fixing divertors of approved make (to the approval of Engineer-in-charge ) for bath and shower system complete in all respect. Single lever concealed divertor for bath and shower system (3 inlet flow) with body and upper part |
| 80 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 81 | PVC tube connection of size 15 mm x 450 mm with Brass nut |
| 82 | Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 83 | C.P. copper tube connection of size15 mm x 600 mm with C.P. Brass nut |
| 84 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 85 | Single Socket Type B |
| 86 | 110mm o/d SWR UPVC pipe lines laid complete |
| 87 | 90mm o/d SWR UPVC pipe lines laid complete |
| 88 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 89 | 110mm o/d |
| 90 | 90mm i/d |
| 91 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
| 92 | M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 93 | M.S. Holder bats clamps for 75mm i/d H.C.I. pipes |
| 94 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 95 | For 110mm o/d pipes |
| 96 | Door Cap |
| 97 | Single Tee With Door |
| 98 | Door Elbow 90 Degree (All side socketed) |
| 99 | Elbow 90 Degree (All side socketed) |
| 100 | Vent Cowls |
| 101 | Coupler |
| 102 | P Trap/Floor Trap 110mm x 75mm |
| 103 | Single Y-Junction |
| 104 | Nahani trap without jali 110mmx90mm |
| 105 | For 90mm o/d pipes |
| 106 | Door Cap |
| 107 | Single Tee With Door |
| 108 | Door Elbow 90 Degree (All side socketed) |
| 109 | Elbow 90 Degree (All side socketed) |
| 110 | Vent Cowls |
| 111 | Coupler |
| 112 | Single Y-Junction |
| 113 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 114 | Size 75 mm x 75 mm |
| 115 | Providing and fixing in position automatic brassBall Cock in tanks. |
| 116 | Brass Ball Cock with rod and Plastic Ball |
| 117 | 25mm i/d |
| 118 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -ncharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 119 | Triple Layer Tanks (3 x 1000) |
| 120 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer- ncharge) in PVC Water storage tanks complete in all respect. |
| 121 | G.I. tank nipple 20mm i/d |
| 122 | G.I. tank nipple 25mm i/d |
| 123 | Dismantling Sanitary fixtures such as Eurpoean / Indian / Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. |
| 124 | Eurpoean/Indian/Orissa W.C., |
| 125 | PVC / China Ware Cistern |
| 126 | Wash Hand Basin / Urinal Pot |
| 127 | CP Bib Cock/Angle Cock |
| 128 | Wall mixer / Sink Mixer / Basin Mixer |
| 129 | Bathroom Accessories |
| 130 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 131 | Horizontal type 25 litre capacity water heater |
| 132 | Horizontal type 80 litre capacity water heater |
| 133 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 134 | Providing and fixing angle iron heavy duty platform for HDPE 1000 Ltr. Tanks including fixing the same with fasteners including cost of material and labour complete in all respects. |
| 135 | Providing and fixing in position Paper Towel Dispenser - Towels with c/z Folds - Wall Mounted capacity: 400-600 C/Z towels material: AISI 304 stainless steel finish: satin Jaquar make (Cat. No. PTD-SAP-DT0106CSN) complete in all respect. |
| 136 | Providing and fixing in position Bolt touch-free infrared hand dryer with 1150W rated power & carbon brush motor Jaquar make (Cat. No. HDR-SSF-AK2803D) complete in all respect. |
| 137 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 138 | Providing and fixing Toilet cubical(of following standard dimension which includes 600mm door size width) made up of thermosetting resign treated high pressure ,self supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing . Compact board should be resistance to water immersion through permissible increase on thickness and mass <0.60% and board density >1.35kg/cm3 and fulfilled the criteria of FSC and green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/97 and EN:438-6 and cleassification of BS1D0 standard. Pilaster to be supported with SS (grade316) adjustable foot and intermediate panels will attached to the wall with the help of approved aluminium channels and all required hardware, made up of stainless steel as per manufacturer’s specification and instruction of Engineer-in-charge like Door knob, gravity hinges,Thumb turn locksets with occupancy indicators ,coat hooks with door stoper , U channel, top rail with corner connector, adjustable foot/pedestal,Rubber noice deafening tape, screw & wall plugs. The top fitting should consist of anodized aluminium metal top rail(as per manufacturer specification) which will directly get fixed with pilaster ,Aluminium corner bend (connected with top rail ) will be use in corner of cubical in absence of brick wall, Aluminium wall fixing is used only on the wall which will hold the top rail. All screw will of 304 grade in SS with stain finish. Pilaster shoud be raised from the the floor with a clearance height upto 150 mm with the help of adjustable leg.Finish and colour of Toilet cubical should be approved under guidance of engineer-in-charge.Classique-Versatile model of Greenlam Sturdo |
| 139 | 1.01- Toilet cubical with standard dimension of 1995mm(H)x1000mm(W)x1500mm(Depth), which includes 600mm door size width or as per drawing. |
| 140 | 1.01- Toilet cubical I- shape(front partition)with standard dimension of 1995mm(H)x1000mm (W) which includes door size width or as per drawing. |
| 141 | 1.01- All aspect specified by the manufacturers , Greenlam sturdo Classique Evergreen model or equivalent. |
| 142 | Carriage of Malba from site of work to dumping ground. |
| 143 | Less Rebate on Old Materials |
| 144 | Sub Head No. 2 Desilting and replacement of Damaged Sewer Lines |
| 145 | Dismantling of Flexible Pavements (By Mechanical Means) |
| 146 | Dismantling of flexible pavements thickness above 50mm by mechanical means and disposal of dismantled materials up to a lead of 1000mtr. |
| 147 | Dismantling concrete |
| 148 | Cement concrete plain1:2:4 mix |
| 149 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code: 15658(2006) |
| 150 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. |
| 151 | For depth not exceeding 3 m. below Ground level |
| 152 | (i) All classes of soil except rocky |
| 153 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness complete in all respects. |
| 154 | 160 mm o/d pipe |
| 155 | 200 mm o/d pipe |
| 156 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming toI.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 157 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 158 | Inside size 150x180 cm and 120 cm deep |
| 159 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto 1.80 m increase in depth. |
| 160 | Inside size 150x180 cm |
| 161 | Cement concrete 1:2:4 |
| 162 | mixing by manual means |
| 163 | Same as Dismantling |
| 164 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. |
| 165 | Depth up to 3 Mtr. |
| 166 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda |
| 167 | Sewer connections upto 300 mm id |
| 168 | Supplying of Tibba Sand |
| 169 | For 200 mm pipe |
| 170 | Plugging of Manhole with the help of sand filled bags including cost of sand and labour complete Job. |
| 171 | Pumping out water for execution of work. |
| 172 | Repair of Manhole of size 5' x 3' complete in all respects |
| 173 | Raising of MH RCC Slabs including excavation, demolishing old slab and casting new RCC slab and other works contingent thereto. |
| 174 | Shifting of services like electric cable, electric connection, Telephone cables, Mobile cables, repair of Storm Dart etc complet in all instructs |
| 175 | Shifting and re-installing of electrical cable / electrial connection and other related provisions complete in all respects. |
| 176 | Shifting and re-installing of telephone cables / mobil or internet wiring cables etc. and other related provisions complete in all respects. |
| 177 | Shifting and relaying of storm dart / sewer system etc. and other related provisions complete in all respects. |
| 178 | Sub Head No. 3 (Rain Water and drainage ) |
| 179 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. |
| 180 | Depth up to 3 Mtr. |
| 181 | Excavation manually in trenches with straight or open cutting in a builtup street/Lanes having wall to wall width upto 3 meter for sewer and manholes to full depth as shown in drawings including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning roads, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 mtr., for all works other than connections to complete in all respects. |
| 182 | For depth not exceeding 2 m. below Ground level |
| 183 | (i) All classes of soil except rocky |
| 184 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 185 | Inside size 90x150 cm and 120 cm deep |
| 186 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.56 upto1.80 m increase in depth. Inside size 90x150 cm |
| 187 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. |
| 188 | R.C.C. Pipe NP -3 |
| 189 | 300 mm i/d Pipe |
| 190 | Cement concrete 1:2:4 |
| 191 | mixing by manual means |
| 192 | Cement concrete 1:4:8 |
| 193 | With stone aggregate 40mm |
| 194 | Mixing by Manual Means |
| 195 | Providing & Fixing RCC Road Gully grating & frame RCC Road Gully grating & frame size 610mm*300mm |
| 196 | Repair / raising of manhole including cost of material & labour complete job. |
| 197 | Desilting of Road Gully including of safty measures cost of container T&P and disposal of Sludge upto 5 Km complete in all respects. |
| 198 | Desilting of Storm line with jetting machine complete in all respects. |
| 199 | Upto 10\\" Storm line |
| 200 | Plugging of Manhole with the help of sand filled bags including cost of sand and labour complete Job. |
| 201 | Pumping out water for execution of work. |
| 202 | Sub Head No. 4 (Fire Fighting Services) |
| 203 | MS PIPE(on surface) |
| 204 | Providing laying, testing and commissioning of C class heavy duty MS Pipe conforming to Indian Standard IS:1239/3589 including fittinge like elbows, tees, flanges, tapers, nutts, gaskets, nuts, bolts etc. on surface providing angle iron support or cement concrete block as support including painting with two or more coats of synethetic enamel paint or required shades complete in all respects. |
| 205 | 150mm |
| 206 | 200mm |
| 207 | Hydrant landing Valve |
| 208 | S/I/T/C of GM single headed hydrant valve with instantaneous Gun metal peet coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 with blank gunmetal cap and chain including orifice olate made of 6mm stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects. |
| 209 | Branch Pipe |
| 210 | S/I/T/C 63mm dia gun-metal branch pipe ISI marked with 20mm size gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 211 | Supplying, Installation, Testing and Commissioning of Single suction collecting head with cast iron body, nose coupling (draw out connection) with female outlet complete bolts, nuts and rubber insertions, but without 100mm dia. MS suction pipe (with puddle flange) with a foot valve, complete as required. |
| 212 | XLPE INSULATED LT CABLES: XLPE INSULATED ARMOURED CABLES(UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- Overall size 10sq.mm (4Core) Armoured(Underground) |
| 213 | Fire Brigade Inlet |
| 214 | Providing and fixing fire brigade inlet connection of cast iron body with gun metal 63mm dia instantaneous type male coupling with built in check valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS: 904. |
| 215 | Four way Inlet connection |
| 216 | Two Way inlet connection |
| 217 | RRL Hose Pipe |
| 218 | S/I/T/C of RRL fire hose type A IS:636, 63mm diax15m long with gunmetal male and female couplings bound and riveted to hose pipes with copper rivets and copper wire as required. |
| 219 | First-Aid Hose Reel |
| 220 | S/I/T/C of First-Aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 mtr long type with main pipe complete in all respect. |
| 221 | Pressure Switch |
| 222 | Providing fixing testing & Pressure Switch in the M.S. Pipe Line including connection etc. as required. |
| 223 | Pressure Gauge |
| 224 | providing and fixing of Pressure Guage in M.S Pipe Line (pressure range 0-10 Kg/cm2) suitable. |
| 225 | Dia diameter 150mm calibration 0-16kg. |
| 226 | Butterfly Valve |
| 227 | Supply, laying, Testing and Commissioning of ISI marked Butter Fly Valve tested for minimum Pressure of 16 kg/cm complete with rubber insertion, nuts bolts and washers, matching Flanges of required Thickness etc. complete as per specification. |
| 228 | 80mm i/d |
| 229 | 100mm i/d |
| 230 | 150 mm i/d |
| 231 | Non-Return Valve |
| 232 | NON RETURN VALVE-providing & fixing dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut bolt, rubber insertion etc. complete. |
| 233 | 100mm |
| 234 | 150mm |
| 235 | Fire Extinguisher ABC 6 Kg |
| 236 | providing and fixing of fire extinguisher ABC type of 6 kg capacity. |
| 237 | Fire Extinguisher CO2 4.5 kg |
| 238 | providing and fixing of fire extinguisher Co2 type of 4.5kg capacity. |
| 239 | Mechanical Foam type Fire Extinguisher |
| 240 | Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect. |
| 241 | Brass Ball Valve |
| 242 | Providing, fixing and joining Brass Ball valves screwed with SS/BRASS ball and spindle and Teflon seats, on G.I. Pipe lines including all carriages complete. 25mm. |
| 243 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. 900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant) |
| 244 | Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 245 | Providing, supplying, installing, testing and commissioning of main electrical control panel for fire fighting system, fabricated from M.S. sheet of approved thickness, dust and vermin proof, complete with MCCB/MCB, contactors, relays, indicating lamps, meters, wiring, bus bars and all allied accessories, complete in all respects as per approved specifications and directions of Engineer-in-Charge. |
| 246 | Providing, supplying, installing, testing and commissioning of 200 Ltr. capacity fuel tank made of M.S. sheet of approved thickness, complete with necessary inlet, outlet, drain arrangement, mounting frame and allied accessories, complete in all respects as per approved specifications and directions of Engineer-in-Charge. |
| 247 | Providing and applying fire wrapping and fire resistant coating treatment of approved make and specification on pipes/cables/structural members as required, complete in all respects as per manufacturer specifications and directions of Engineer-in-Charge. |
| 248 | Repairing, servicing, testing and commissioning of main electrical fire fighting pump set including replacement of worn-out parts, bearings, mechanical seals, coupling, rewinding of motor (if required), lubrication and allied works, complete in all respects to ensure proper functioning of the fire fighting system as per directions of Engineer-in-Charge. |
| 249 | Repairing, servicing, testing and commissioning of diesel engine driven fire fighting pump set including repair/replacement of worn-out parts, bearings, mechanical seals, coupling, engine servicing, battery checking, fuel system servicing, lubrication and allied works, complete in all respects to ensure proper functioning of the fire fighting system as per directions of Engineer-in-Charge. |
| 250 | Repairing, servicing, testing and commissioning of jockey pump set including replacement of worn-out parts, bearings, seals, coupling, rewinding (if required), lubrication and allied works, complete in all respects to ensure proper functioning of the fire fighting system as per directions of Engineer-in-Charge. |
| 251 | Dismantling and reinstatement/reconciliation of civil works including cutting of walls, floors, plaster, masonry, excavation and making good the same after completion of fire fighting works, complete in all respects to the original finish as per site requirement and directions of Engineer-in-Charge. |
| 252 | Providing consultancy services for preparation of drawings, design, inspection, supervision, testing and obtaining necessary NOC/approvals/completion formalities for fire fighting system works, complete in all respects as per applicable norms and directions of Engineer-in-Charge. |
| 253 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 9 Kg. Capacity |
| 254 | Providing and fixing of FIRE EXTINGUISHER, Water CO2 type as per IS: 15683complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. 9 Kg. Capacity |
| 255 | Providing and applying fire resistant paint/coating of approved make and specification on the required surface, complete in all respects as per manufacturer specifications and directions of Engineer-in-Charge. |
| 256 | Sub Head No. 5 (Providing Tubewell including delivery, machinery etc.) |
| 257 | Drilling of 500mm dia bore with reverse rotary rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. Complete in all respects. |
| 258 | Drilling of 500mm dia bore with reverse rotary rig upto 150 mtr depth BGL. |
| 259 | Drilling of 500mm dia bore with reverse rotary rig beyond 150 mtr depth upto 300 mtr depth |
| 260 | Drilling of 500mm dia bore with Reverse Rotatry Rig Beyond 300 m depth BGL to onward depth |
| 261 | 1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of Water and Water for drilling tube-well be arranged by the firm/ contractor at site at his own cost. |
| 262 | 2. In case the bore is converted into a tube-well payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling. |
| 263 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect. |
| 264 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. |
| 265 | 250mmnominal diameter (weight 52.3 kg per metre) 8.0 mm thickness |
| 266 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. |
| 267 | 250mm Steel Strainer (slot size 0.75mm) 7.30 mm thickness |
| 268 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. |
| 269 | 250mm internal diameter (weight 52.3 kg per metre) 8.00 mm thickness |
| 270 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. |
| 271 | 250mm internal diameter |
| 272 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 273 | 250mm internal diameter |
| 274 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 275 | 300mm internal diameter |
| 276 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 277 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 278 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 279 | Supplying and fixing Mild steel centering guide made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 280 | Supplying and fixing sanitary seal having rubber tight on housing pipe . Complete job in all respect 250 mm dia (As per BIS:2800-2019)(As per IS:2800-2019) |
| 281 | Supplying of tibba sand /local sand over gravel packing & clayseal, upto G.Level between pipe assembly and bore including carriage . Complete job in all respect (upto 75 mt depth approx.) |
| 282 | Supplying of clay to provide imprevious layer in between pipe assembly and bore above gravel packing including carriage of material. Complete in all respect. (As per BIS:2800-2019) |
| 283 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments .( to be paid as per actual length of pipe) |
| 284 | Provision for Sterilisation of tubewell with sodium hypochorlide/ chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well .The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time , the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water . IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce. |
| 285 | Testing of water sample for .Heavy metal from approved laboratory (Aluminium, selemium, cadmium, chromium, lead, mercury, arsenic, nickel & uranium pesticide etc.) |
| 286 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 287 | Capacity of Air compressor 550 cfm at 600 PSI |
| 288 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 289 | PUMPING MAIN (RISING MAIN) |
| 290 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation. |
| 291 | 110mm o/d pipe of 10kg/sqcm |
| 292 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) |
| 293 | 100 mm I/d |
| 294 | Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 295 | Pumping Machinery |
| 296 | Providing, installing, testing and commissioning of 1 no. Electrically driven submersible pumping set of reputed make of 8 stage 25 HP cap. Complete in all respects |
| 297 | Supplying lowering of 100 mm dia GI pipe as per IS 1229 including GI sockets complete in all respects |
| 298 | Providing and fixing of submerssible of 10 mm ² , 3core cable , complete in all respect |
| 299 | P/F control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays , isolator switches wiring and connnections. Complete in all respect . |
| 300 | P/F delivery line for submersible pump, CI Specials, NRV, Duck Foot Bend and other required accessories complete job |
| 301 | Sub Head No. 6 (Machinery for UGSR) |
| 302 | Providing and installing 7.5 HP mono block pump of reputed make size 50 x 40mm Head 54Mtr. Complete in all respects. |
| 303 | P/F control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays , isolator switches wiring and connnections. Complete in all respect . |
| 304 | Sub Head No. 7 (Providing and installing Air Conditioners) |
| 305 | Providing and installing O-General/ Daikin / Hitachi / Toshiba/ Mitsubishi/ Carrier make 5 Star rating (Hiwall colling only with installation kit i.e. copper pipe) or any other equivalent make Split Type Air Conditioner of 1.5 /2.0 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering including installation charges. |
| 306 | Providing and fixing Plug Top for fixing with stabilizer complete in all respect. |
| 307 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 308 | Providing and fixing refrigerant copper pipe (Type B) for Split type Air Conditioner including insulation complete in all respects of approved make. |
| 309 | Providing and fixing 15 mm i/d PVC drain pipe with insulation to prevent seepage in walls with specials for Split type Air Conditioner complete in all respects of approved make. |
| 310 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects. |
| 311 | Providing and fixing powder coated angle iron stand heavy duty including grouting for out door unit complete in all respects. |
| 312 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 313 | Size 75 mm x 75 mm |
| 314 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 315 | Through wall 22.86 cm thick |
| 316 | Ductable HVAC for VIP Lounge |
| 317 | Ductable Machine |
| 318 | Supply, Installation, Testing and Commissioning of \\"Carrier Make\\" 11.0 TR Ductable Machine combination of Indoor and outdoor, with AC panel, Scanner protection for HP high/low voltage, single phasing, phase imbalance . Outdoor Unit houses the scroll compressor. Pressure Testing, Nitrogen Testing, Vaccumisation, Gas Charging, loading, unloading, Transportation etc. |
| 319 | PIPING & INSULATION (Refrigerant Piping) |
| 320 | Supply, Installation, testing and commissioning of of Interconnecting refrigerant pipe work with ( 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. |
| 321 | 28.6 mm Copper Pipe(19mm thick insulation) |
| 322 | 15.88mm Copper Pipe(19mm thick insulation) |
| 323 | Control & Transmission Wiring |
| 324 | Providing & fixing control cum transmission wiring of copper in PVC conduits between indoor and outdoor unit.For 11.0 TR Machine (1.5 sqmm. X 3Core) & (2.5 sqmm. X 4Core) |
| 325 | Installation, testing and commissioning of PVc piping complete with fittings, supports as per specifications |
| 326 | 32 mm Dia |
| 327 | MS Stands for Outdoor Units |
| 328 | MS Platform stands, Angle Stands Iron made |
| 329 | For 11.0 TR Machine |
| 330 | AIR DISTRIBUTION & INSULATION |
| 331 | DUCTING |
| 332 | Supply, installation, testing and commissioning of factory fabricated GSS sheet metal ducting for Supply air/exhaust air as per ducting specifications and with suitable supports using MS angles, channels, rods, anchor bolts, etc to roof / truss as per IS 655 and as per specifications including sizing of ducts. |
| 333 | Supply, installation, testing and commissioning of 32 kg/m3 density fiberglass insulation in the form of 12 mm Thick Fiber Glass boards, 2 Layers of Tissue paper finished with 28 gauge perforated Aluminum sheet with nuts, bolts complete as per specifications. |
| 334 | 12 mm thickness Acoustic lining |
| 335 | External thermal insulation on supply air ducts |
| 336 | Supply, installation, testing and commissioning of 16kg density 13 mm thick external Thermal insulation on supply air ducts using Close cell cross linked Nitrile rubber insulation as per specifications. Al faced |
| 337 | Supply, fabrication, installation, testing of flexible connections made out of fire resistant flexible double canvas sleeve for Ductable Machines and Inline Fans. |
| 338 | Grills & Diffusers |
| 339 | Supply, Installation, Testing and Balancing of Powder coated extruded aluminum construction Linear Grilles / Discreet grills as per approved drawings and specifications. Quoted price shall be without volume control damper at the location of supply air collar. |
| 340 | Supply, Installation, Testing and Balancing of Powder coated (black matt finish) extruded aluminum construction Collar volume control dampers as per approved drawings and specifications at the location of supply air collar. |
| 341 | Insulation of Boxing with 50 mm thick fibre glass wool, Al faced having density of 16kg/CUM |
| 342 | Dismantling of existing ac's with Indoor/ Outdoor/ Ducting/ Grills etc. |
| 343 | Lifting Shifting of Indoor / Outdoor unit with Hydra / Crane |
| 344 | Credit for old Split Type Air Conditioners |
| 345 | Credit for old Ductable HVAC |
| 346 | Sub Head No. 8(Astroturf Watering System ) |
| 347 | Supply of heavy-duty underground pop-up turbine sprinkler system for sports fields/large landscape areas, consisting of long-radius pop-up sprinklers suitable for automatic irrigation applications, having 2” female threaded inlet connection, adjustable rotation speed mechanism, operating pressure range from 3 to 8 bar, throw radius up to 50 meters, discharge capacity up to 1262 LPM, and interchangeable nozzles ranging from 16 mm to 26 mm. The sprinkler body shall be manufactured from high-strength engineering plastic and corrosion-resistant components suitable for continuous outdoor operation. The system shall include all necessary fittings, swing joints, valve boxes, HDPE/uPVC piping connections, accessories, and installation works complete as per manufacturer recommendations. The sprinkler shall be suitable for sports turf irrigation with a trajectory angle of approximately 25° and optional artificial grass cap arrangement for safety and aesthetic integration. |
| 348 | Supply of medium-high flow turbine gun sprinkler (Rain Gun) suitable for agricultural, industrial and solid set irrigation applications, having 2½” female threaded inlet connection, 25° trajectory angle, and interchangeable nozzle sizes ranging from 18mm to 38mm.Therain gun shall becapable of operating within a pressure range of 2 to 7 bar, delivering discharge up to 1872 LPM with maximum throw radius up to 64.5meters.The unit shall be manufactured from corrosion-resistant aluminum alloy and high-strength engineering components, complete with smooth turbine-driven rotation mechanism and suitable for continuous outdoor operation. The rain gun shall conform to manufacturer’s standard technical specifications and performance parameters. |
| 349 | Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.), painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 350 | 15 mm i/d |
| 351 | 20 mm i/d |
| 352 | 25 mm i/d |
| 353 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 354 | 15 mm i/d G.I. Union |
| 355 | 20 mm i/d G.I. Union |
| 356 | 25 mm i/d G.I. Union Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail