| 1 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, including the cost of diversion for traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 2 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 3 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth |
| 4 | 10 mm thick cement plaster with cement mortar 1:4 on floors for bed & top of side walls |
| 5 | 10 mm thick cement plaster with cement mortar 1:4 on side walls |
| 6 | Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement |
| 7 | Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle |
| 8 | Cement concrete 1:4:8 with brick ballast 40mm gauge |
| 9 | Supply of RCC NP-2 600 mm i/d pipe as per Rate Contract |
| 10 | Supply of RCC NP-2 150 mm i/d pipe as per Rate Contract |
| 11 | Providing,lowering precast concrete NP-2 Plain end pipes and collar with reinforcement. in trenches to correct gradient and alignment,cutting of reinforcement cement concrete plain end pipes,stringing in trenches,jointing ends and fixing collar with cement mortar 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment,gradients,levels etc complete in all respect RCC NP-2 600 mm i/d pipe.(Excluidng Supply of Pipe) |
| 12 | Providing,lowering precast concrete NP-2 Plain end pipes and collar with reinforcement. in trenches to correct gradient and alignment,cutting of reinforcement cement concrete plain end pipes,stringing in trenches,jointing ends and fixing collar with cement mortar 1:2 as per IS 458:2003 into trenches for all depths and laying out same to correct alignment,gradients,levels etc complete in all respect RCC NP-2 150 mm i/d pipe.(Excluding Supply of Pipe) |
| 13 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design |
| 14 | Supply of M.S ISA,ISMC,ISMB, Plate etc |
| 15 | Providing and laying,jointing,fixing,testing ISI marked GI pipe B-Class, including cost of specials such as tees,bends,sockets,elbow etc, cutting threading and testing in trenches in the ground complete. (b) 20mm dia |
| 16 | Welding by gas or by electric plant, including carriage to and from workshop |
| 17 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 18 | Providing of Alfa valve of 600 mm dia complete excluding all tax and charges |
| 19 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)(A) Class PN-1 as per ISI (k) 600mm i/d Sluice Valves flanged |
| 20 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m. |
| 21 | Any Other Item Please Enable Macros to View BoQ information |