Tender For Providing Of Fast Erectable Modular Shelters For Variopus Op Lacations On Leh- Demchok Axis In South Eastern Ladakh, Udhampur-Jammu And Kashmir
TDR : 55752837
Tender Notice
BOQ
14 Days Left
Udhampur
Jammu And Kashmir
Tender For Providing Of Fast Erectable Modular Shelters For Variopus Op Lacations On Leh- Demchok Axis In South Eastern Ladakh
Name of Work:- Provn of Fast Erectable Modular shelters for variopus Op Lacations on Leh- Demchok axis in South Eastern Ladakh
Sl. No.
Item Description
1
Supply, Installation ,commissioning and testing of Central heating plant with glycol based Hot water generator of minimum capacity 2.0 lakh K Cal/hr using kerosene/HSD oil complete with combustion chamber and equiped complete with automatic monoblock burner assembly fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, 3 phase 440 volts AC supply complete all as specified and directed Make: Thermax, Ecoflame, Western, Rapidtherm, Alphatherm (a)Heater unit:-Heat exchanger ,consisting of closely wound, helical concentric coils, arranged to give adequate no. of passes on flue gas side & made out of ERW tubes confirming to IS 3059 Pt-I suitable for high temperature all as per manufacturer design and of required head and capacity . (b) Pressure jet burner:-Suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contactors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity. Note :- (I) The boiler shall be installed in system of (1W+1S) (II) The tenderer should get the plant installed by any of the original equipment manufacturer with recommended makes of compatible components of items. (III) The boiler minimum specification should be as under :- (i) The boiler inner shell be made from carbon steel with dished ends (curved type) with thickness as per boiler design of OEM. (ii)Outer shell be made from carbon steel with thickness as per boiler design of OEM. iii) Boiler tube shall be seamless MS tube for quality commensurate with the boiler requirement . (iv) The front door shall be openable lined with high grade insulation and refactory (v)High efficient, low noise imported monoblock burner (Benton/Rello) (vi)The boiler shall be insulated with 50mm thick resin bonded fibre glass wool and cladded with 22 guage GI sheet (epoxy pointed) or any other thermal insulation as per OEM design. (vii)Pre wired control panel (made from 18 guage CRC sheet ) Main incomer, MCB in/out temperature controller (digital)fault indicating light for water high temp, burner trip,flue temp, with alarm, hour meter for maint schedule etc. (viii) 1 set of oil piping from unit to burner . (ix) It includes suitable concrete foundation for Boiler . Please Enable Macros to View BoQ information
2
Supply, Installation ,commissioning and testing of Central heating plant with glycol based Hot water generator of minimum capacity 2.0 lakh K Cal/hr using kerosene/HSD oil complete with combustion chamber and equiped complete with automatic monoblock burner assembly fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, 3 phase 440 volts AC supply complete all as specified and directed Make: Thermax, Ecoflame, Western, Rapidtherm, Alphatherm (a)Heater unit:-Heat exchanger ,consisting of closely wound, helical concentric coils, arranged to give adequate no. of passes on flue gas side & made out of ERW tubes confirming to IS 3059 Pt-I suitable for high temperature all as per manufacturer design and of required head and capacity . (b) Pressure jet burner:-Suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contactors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity. Note :- (I) The boiler shall be installed in system of (1W+1S) (II) The tenderer should get the plant installed by any of the original equipment manufacturer with recommended makes of compatible components of items. (III) The boiler minimum specification should be as under :- (i) The boiler inner shell be made from carbon steel with dished ends (curved type) with thickness as per boiler design of OEM. (ii)Outer shell be made from carbon steel with thickness as per boiler design of OEM. iii) Boiler tube shall be seamless MS tube for quality commensurate with the boiler requirement . (iv) The front door shall be openable lined with high grade insulation and refactory (v)High efficient, low noise imported monoblock burner (Benton/Rello) (vi)The boiler shall be insulated with 50mm thick resin bonded fibre glass wool and cladded with 22 guage GI sheet (epoxy pointed) or any other thermal insulation as per OEM design. (vii)Pre wired control panel (made from 18 guage CRC sheet ) Main incomer, MCB in/out temperature controller (digital)fault indicating light for water high temp, burner trip,flue temp, with alarm, hour meter for maint schedule etc. (viii) 1 set of oil piping from unit to burner . (ix) It includes suitable concrete foundation for Boiler . Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.