Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and Carrying out the comprehensive cum routine & day to day maintenance of street lights by using Tower Wagon , ladders & all other relevant and suitable tools & plants required for smoothly, healthy & proper illumination on roads by maintaining & repair of all types and wattage of LED street lighting on the various PWD Roads complete with & Providing and fixing of LED driver, LED lens & relevant accessories and Providing & laying of UG/ Overhead Cables up to 40 Metre of suitable size with 6SWG GI Wire, feeder pillars accessories like MCCB's, Contactors, Relays, Bus Bars, timers, panel wirings, pole wiring / cables, lugs, nuts and bolts, cable joints etc and ensuring security thereof and to prevent theft of electricity from street light installations complete including daily inspection of roads & submit the daily inspection report to concerned JE(E) / AE(E) and preparation of data as required. (Inventory of points / roads attached) and as per terms and conditions attached). (in case of defect in fitting shall be removed from the pole shall be given to the JE(E) incharge of report) For removal and reinstallation is in the scope of work.Qty. For NESD-I (Total LED Fittings -2527Nos., Total Points = 2527 X 12 Months=30324 Points) Qty. For NESD-III (Total LED Fittings -2451Nos., Total Points=2451X12 Months=29412 Points) |
| 2 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. a) 100 A, 16 KA,TPMCCBQty. for NESD-I - 30 NosQty. for NESD-III - 50 NosTotal |
| 3 | b) 125 A, 16 kA,TPMCCB Qty. for NESD-IQty. for NESD-III |
| 4 | Supplying and fixing 5 amps to 32 amps rating, 240 / 415 volts, 'C' series,10KA miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single PoleQty. for NESD-I - 175 NosQty. for NESD-III - 225 NosTotal |
| 5 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.Qty. for NESD-I - 12 SetsQty. for NESD-III - 18 SetsTotal |
| 6 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)Qty. for NESD-III |
| 7 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.Qty. for NESD-I - 75 MtrsQty. for NESD-III - 15 Mtrs |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.Qty. for NESD-I - 230 MtrsQty. for NESD-III - 100 Mtrs |
| 9 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.Qty. for NESD-I - 11000Qty. for NESD-III - 9800 |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mmQty. for NESD-I - 2000 MtrsQty. for NESD-III - 6200 Mtrs |
| 11 | b) Above 35 sq. mm and upto 95 sq. mmQty. for NESD-I |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle)Qty. for NESD-I |
| 13 | b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)Qty. for NESD-I |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 4 X 16 sq. mm (28mm)Qty. for NESD-I - 60 NosQty. for NESD-III - 15 Nos |
| 15 | b) 4 X 25 sq. mm (28mm)Qty. for NESD-I - 60 NosQty. for NESD-III - 20 Nos |
| 16 | c) 4 X 50 sq. mm (35mm) - 8 NosQty. for NESD-I |
| 17 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade i/c dismantling as required.a) 4 X 25 sq. mm/4 X 35 sq.mmQty. for NESD-I - 10 Nos |
| 18 | b) 4 X 50 sq. mmQty. for NESD-I- 4 Nos |
| 19 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.Qty. for NESD-I - 100 SetsQty. for NESD-III - 195 Sets |
| 20 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposalof surplus excavated soil as directed, within a lead of 50 metres.Qty. for NESD-I - 125 cumQty. for NESD-III - 125 cum |
| 21 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)Qty. for NESD-I - 500 MtrsQty. for NESD-III - 4300 mtrs |
| 22 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal)Qty for NESD-I - 600 mtrsQty NESD - III - 200 mtrs |
| 23 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal)Qty. for NESD-I - 700 mtrs |
| 24 | b) 90 mm dia (OD-90 mm & ID-76 mm nominal)Qty. for NESD-I |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth levela) 1:3:6 (1 Cement : 3 coarse sand (zone-III) drived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)Qty. for NESD-I - 15 cumQty. for NESD-III - 15 cum |
| 26 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.a) 2 mm thick flatQty. for NESD-I - 110 Sq mtrQty. for NESD-III-30 sq mtr |
| 27 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargea) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)Qty. for NESD-I - 25 cumQty. for NESD-III - 25 cum |
| 28 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.Qty. for NESD-I - 20 cumQty. for NESD-III 25 cum |
| 29 | Supplying and fixing of factory fabricated wall /floor mounted outdoor type double hinged door distribution box (1000 X 690 x 215) mm size made out of (SMC) sheetmoulding compound dust & weather proof with front openable hinged type cover with canopy and locking arrangement i/c providing & fixing of following accessories etc, connections, testing & commissioning complete as reqd.a) 160 Amp. 25 KA FP MCCB - 1 No.b) 70 Amp. AC3 duty 4 Pole power contactor 1 No.c) 100 Amp 16 KA FP MCCB 4 Nos.d) Auto manual selector switch-1 Noe) Astronomical timer suitable for 1 output per phase and suitable for single phase supply 1 No.f) Three phase busbar i/c inter connection with copper wire. etc. complete as reqd.(The pole box shall be mounted on wall/floor on existing RCC foundation).Qty. for NESD-I - 4 job |
| 30 | Provision for pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required.a) 32 Amp 5 Way connector with bakelite base.b) 6 Amp SP MCB 'C' Curve (10 KA) - 1 No.c) Earth Studs - 2 Sets.d) 40 x 5 mm clamp with 2 Nos. 3/8\\" Nut & Bolts - 1 Set as required.Qty. for NESD-III - 45 Nos |
| 31 | Providing boring by trenchless technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-in-charge with moling equipment i/c jointing cleaning, rodding of pipe providing suitable covers on mouth of pipes, excavation of pits of required size at a following depth i/c refilling etc. complete as reqd.a) 0.75 Mtr to 1.5 Mtr. depth. Qty. for NESD-I - 75 mtrsQty. for NESD-III - 225 mtrs |
| 32 | Fabricating, supplying and fixing of wire mesh protection frame work fabricating with 40 x 40 x 6 mm thick angle iron/Tee iron having intermediate members of size 25mm x 6 mm flat strip welded at 30 cm in each horizontal sections & duly welded with hard drawn wire fabric mesh of size 25 mm X 75 mm (GI wire should be 6SWG) having weight not less than 7.5 Kg/Sqmtr. and making main door gate provided with two nos. sliding bolt with 02 nos. godown inter locks with operating hadle welded from inside of the door i/c providing and fixing of four no. legs of same angle size of 90 cm length duly grouted in foundation (30 x 30 x 45) cm (deep) in 1:2:3 cement concrete & painting with one coat of red oxide & two coat of super synthetic luminous paint of approved colour and quality etc. complete as complete as reqd. {Area of hard drawn wire fabric with angle (Except legs) shall be measured for payment}Qty. for NESD-I - 100 SqmtrQty. for NESD-III - 100 Sqmtr |
| 33 | Supplying & Fixing of Hot molded SMC (Sheet molded Compound) street light pole termination window cover for following size of street light poles complete with rubber gasket. G.I. Mounting strip and bolt for mounting,locking arrangement, color steel grey. Suitable for 5/8/10/12 mtr G.I. Octagonal Pole (having thikness 3mm)Qty. for NESD-I - 150 NosQty. for NESD-III - 150 Nos |
| 34 | Repairing of 12 Mtr/ 10 mtr/ 8 mtr long Pole window i/c disconnection of existing cable and dressing of cable, thimbling and taping as per actual requirement in each window, providing and fixing 63 Amp 4 pole stud terminal connector, refixing of dressed cable etc. with the help of ladder complete as reqd.Qty. for NESD-I |
| 35 | Providing services of 02 Nos. commercial maintenance van/ inspection vehicle not older than 2022 (CNG/Petrol) with fuel including driver having valid license for street lights/ underpasses/ other various works on PWD road on all working days of the month except sundays and holidays as per instruction/ directions of Engineer-in-charge. etc as reqd. The vehicle shall be stationed at Sub-Division Office untill completion of the agreement.01 No. for NESD-I & 01 No. for NESD-III |
| 36 | Extra for provision of GPS on 02 Nos. Maintenance van (as per Item No. 26) including its operation maintenance of GPS record on website and its report generation as per direction of Engineer-in-charge.For NESD-I & NESD-III |
| 37 | Supplying and fixing of not less than 250 mm x 200 mm x 105 mm, weather proof SMC/FRP/ Thermoplastic junction box (having cable entries Knockouts) for outdoor application, dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of 4 Pole bakelite connector for cable connection not less than 40 Amp rating capacity, 6 A SP MCB & PVC cable glands suitable for 3.5 x 35 sqmm / 4 x 25 sqmm /4 x 16 sqmm and fixing the box to the pole at a height upto 12 mtrs with the help of MS angle iron frame/Clamp with nut bolts etc. complete as required.Qty. for NESD-I - 120 NosQty. for NESD-III - 50 Nos |
| 38 | Supplying and fixing 40A 3Pole/230V rating Timelite Distribution board surface mounted outdoor type dust & weather proof with front openable hinged type cover with locking arrangement, IP-54 Protection i/c 40A 3P MCB, Astronomical Time Switch, Contactor of suitable rating depends on the luminaires and wattage of lighting loads complete with interconnections, powder painted including earthing etc. as required. (The DB shall be mounted on 10/12 Mtrs GI Pole at height not less than 2.5 mtr.)Qty. for NESD-I |
| 39 | Laying of existing al. conductor armoured/unarmourd power cable 1.1 KV between pole to pole with the help of tower wagon, in following manner, material shall be supplied by department.Upto 3.5X35 sqmm. Overhead with 10 SWG GI wire tied with suitable size MS Clamp.Qty. for NESD-I - 2500 MtrsQty. for NESD-III - 2000 Mtrs |
| 40 | Repairing of defective/faulty cable connection inside the pole window and making connection with suitable size PVC insulated copper wire, connector plate, thimble and taping with insulation tape for existing 5 mtr. to 12 mtr. height GI pole i/c testing & commissioning etc. complete as required at site.Qty. for NESD-I - 250 JobsQty. for NESD-III - 250 Jobs |
| 41 | Fabrication, Designing, Supplying & Fixing of hot dip Galvanized arm bracket of suitable length single/double over hang having minimum 30 cm length with tightening bolt etc. (Design approved by Engineer-in-Charge).Qty. for NESD-I - 200 KgQty. for NESD-III - 100 Kg |
| 42 | Supplying and replacement of burnt out timer/contactor/MCCB in the existing feeder pillar i/c connection and credit same etc. as reqd.a) Digital Timer Qty. for NESD-I - 25 NosQty. for NESD-III - 10 Nos |
| 43 | b) 70 amp 3 Phase Contactor (MNX 70)Qty. for NESD-I - 8 NosQty. for NESD-III 8 Nos |
| 44 | c) 110 amp 3 Phase Contactor (MNX 110)Qty. for NESD-I - 4 NosQty. for NESD-III - 4 Nos |
| 45 | SITC of Single Section GI Octagonal Pole of 12 mtr. height made from 4mm thick HT Steel plate, having minimum bottom dia of 200 mm. & top dia of 100 mm. complete with window with hinged cover at a height of 2.5 mtrs. from the base for cable termination block etc. and galvanized base plate of minimum size 320mm X 320mm X 20 mm thick on existing cement concrete pedestal as required. i/c supplying and fixing of the following in the window box provided for cable termination i/c making connection with suitable size aluminium lugs and testing commissioning etc. as reqd.:-a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd.b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2Nos. welded at suitable height 2 nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable.e) The foundation bolts shall have check nuts and nuts shall be welded with the bolts. The nut-bolts shall be covered with cement concrete of ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto a height of 30 cm above foundation.Qty. for NESD-I |
| 46 | Fabrication, supply and erection of flange mounted hot dip Galvanized Octagonal Poles of 10 mtrs. height made from 4 mm thick HT Steel plate, having minimum bottom dia of 200 mm. & top dia of 90 to 100 mm. complete with window with hinged cover at a height of 2.5 mtrs from the base for cable termination block etc. and galvanized base plate of nominal size 320mm X 320mm X 20mm thick to suit the existing foundation at site as required i/c supplying and fixing of the following in the window box provided for cable termination :- a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd. b) Supplying and fixing of 40 Amp terminal block suitable for 16/25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2 Nos. welded at suitable height two nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25 sqmm cable.e) The nuts and bolts shall be welded/covered with cement concrete of ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto a height of 30 cm. above foundation.Qty. for NESD-I - 4 JobsQty. for NESD-III - 4 Jobs |
| 47 | Fabrication, supply and erection of flange mounted hot dip Galvanized Octagonal Poles of 8 mtrs. height made from 4 mm thick HT Steel plate, having minimum bottom dia of 150 mm. & top dia of 70 mm. complete with window with hinged cover at a height of 1.5 mtrs from the base for cable termination block etc. and galvanized base plate of nominal size 240mm X 240mm X 16mm thick to suit the existing foundation at site as required i/c supplying and fixing of the following in the window box provided for cable termination :- a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd. b) Supplying and fixing of 40 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2Nos. welded at suitable height two nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25 sqmm cable.e) The nuts and bolts shall be welded .The nut-bolts of the foundation shall be covered with cement concrete of ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto a height of 30 cm. above foundation.Qty. for NESD-I |
| 48 | Fabrication, supply and erection of flange mounted hot dip Galvanized Octagonal Poles of 5 mtrs. height made from 3 mm thick HT Steel plate, having minimum bottom dia of 130 mm. & top dia of 70 mm. complete with window with hinged cover at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of minimum size 200mm X 200mm X 12mm thick on existing cement concrete padestal as required.i/c supplying and fixing of the following in the window box provided for cable termination i/c making connection with suitable size aluminium lugs and testing commissioning etc. as reqd.:-a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd.b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2Nos. welded at suitable height two nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable.e) The nuts and bolts shall be welded .The nut-bolts of the foundation shall be covered with cement concrete of ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto a height of 30 cm. above foundation.Qty. for NESD-III |
| 49 | Supplying and fixing 4 Nos. 20 mm (minimum) dia X 750 mm(minimum) long GI foundation bolt (EN8grade) with nuts, washer including 2 Nos. template of 4 mm thick size 240 X 240 mm. with 4 Nos. 20 mm. dia holes (or suitable for existing holes), to match with PCD of Pole base plate as required. (up to 8 Mtr. Pole)Qty. for NESD-I |
| 50 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 600 mm.(L) X 600 mm. wide and 1500 mm. deep i/c excavation of earth in hard rock, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia- 1600mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2400mm (approx) - 10nos. (with equal spacing) R.C.C. work including straightening, cutting, bending, placing in foundation bolts as required with positioning of foundation bolts (as per item below) and providing 63 mm. (O.D) DWC, HDPE Pipe for cable entry & exit as required. (for 8 mtr. Pole)Qty. for NESD-I |
| 51 | Supplying and fixing 4 Nos. 24 mm(minimum) dia X 750 mm (minimum) long GI foundation bolts (EN8grade) with nuts, washer including 2 Nos. template of 4 mm. thick size 320 X 320 mm. with 4 Nos. 28 mm. dia holes, to match with PCD of Pole base plate as reqd.(For 10/12 mtrs. pole)Qty. for NESD-I - 16 JobsQty. for NESD-III - 20 Jobs |
| 52 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 750 mm.(L) X 750 mm. wide and 1800 mm. deep i/c excavation of earth, providing cutting, bending and placing in position, Steel reinforcement of cold twisted bars of 12 mm. dia- 1960mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2900mm (approx) - 13nos. (with 150mm spacing) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete as required with positioning of foundation bolts (as per item below) and providing 90 mm. (O.D) DWC, HDPE Pipe minimum 1 meter for cable entry & exit as required. (For 10/12 mtrs. pole)Qty. for NESD-I - 5 JobsQty. for NESD-III - 5 Jobs |
| 53 | Supplying and fixing 4 Nos. 16 mm(minimum) dia X 650 mm(minimum) long GI foundation bolt (EN8grade) with nuts, washer including 2 Nos. template of 3 mm thick size 200 X 200 mm. with 4 Nos. 20 mm. dia holes (or suitable for existing holes), to match with PCD of Pole base plate as required. (For 5 Mtr. Pole)Qty. for NESD-I - 8 JobsQty. for NESD-III - 8 Jobs |
| 54 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 500 mm.(L) X 500 mm. wide and 1200 mm. deep i/c excavation of earth in hard rock, providing cutting, bending and placing in position, steel reinforcement of cold twisted bars of 12 mm. dia- 1300mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2000mm (approx) - 10nos. (with equal spacing) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete as required with positioning of foundation bolts (as per item below) and providing 63 mm. (O.D) DWC, HDPE Pipe minimum 1 mtr. for cable entry & exit as required. (for 5 meter height pole)Qty. for NESD-I - 8 JobsQty. for NESD-III - 8 Jobs |
| 55 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 90 WattQty. for NESD-I - 15 NosQty. for NESD-III - 40 Nos |
| 56 | b) 120 wattQty. for NESD-I |
| 57 | c) 150 wattQty. for NESD-I - 30 NosQty. for NESD-III - 60 Nos |
| 58 | d) 180 wattQty. for NESD-I |
| 59 | e) 200 wattQty. for NESD-IQty. for NESD-III |
| 60 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 50 wattQty. for NESD-I |
| 61 | b) 200 wattQty. for NESD-I - 20 NosQty. for NESD-III - 10 Nos |
| 62 | c) 250 wattQty. for NESD-I - 20 NosQty. for NESD-III - 20 Nos |
| 63 | Dismantling of Existing Foundation (500x500x1200 mm deep, include 200 mm above road level) using Breaker, JCB and Cutter including cutting the reinsforcement and foundation bolt at a depth of 500 mm below from road level including disposal of Malba to munciple dumping i/c transporting loading and unloading material from site and refiling the empty space with 1:4:8 Cement Concrete etc. complete as required at site upto road level for hindrance free and safe transportation.Qty. for NESD-IQty. for NESD-III |
| 64 | Dismantling of Existing Foundation (600x600x1500 mm deep, include 200 mm above road level) using Breaker, JCB and Cutter including cutting the reinsforcement and foundation bolt at a depth of 500 mm below from road level including disposal of Malba to munciple dumping i/c transporting loading and unloading material from site and refiling the empty space with 1:4:8 Cement Concrete etc. complete as required at site upto road level for hindrance free and safe transportation.Qty. for NESD-III |
| 65 | Dismantling of Existing Foundation (750x750x1800 mm deep, include 200 mm above road level) using Breaker, JCB and Cutter including cutting the reinsforcement and foundation bolt at a depth of 500 mm below from road level including disposal of Malba to munciple dumping i/c transporting loading and unloading material from site and refiling the empty space with 1:4:8 Cement Concrete etc. complete as required at site upto road level for hindrance free and safe transportation.Qty. for NESD-I - 5 NosQty. for NESD-III - 5 Nos |
| 66 | Dismantling of Existing High mast accessories at a height of upto 16 mtrs and Supplying Installation testing and comissioning of winch assembly of upto 16 Mtr high mast, SS Wire rope, Lantern carriage ring,suitable Junction box for cable terminations, winch stand , window cover duly welded to the pole, handle, the double drum winch should be made of minimum 3 MM thick Hot dip galvanised HT steel plate having suitable arrangement of holding minimum 12 Nos flood light fitting of upto 250W i/c fixing, testing etc as reqd.including dismantling and reinstallation ,connections & inter connections of existing flood lights/Street light fitting to the new winch assembly at a height of upto 16 mtrs etc complete as required. (old Dismantling materials are property of Contractor)Qty. for NESD-I |
| 67 | Supplying and drawing following sizes of PVC sheathed & XLPE insulated Al. conductor multicore unarmoured cable of 1100 Volts conforming to IS 7098 (Part 1) 1988 with upto Date Amendments in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.a) 3 core 4 sq.mm Qty. for NESD-I - 1900 MtrsQty. for NESD-III - 1100 Mtrs |
| 68 | Fabrication, supplying, installation, testing & commissioning of out door type totally enclosed weather proof feeder pillar of size with minimum front size 1.25 sqm and 350 mm deep (NS) fully compartmentalised, fabricated from 2mm,thick CRCA sheet and with sloping canopy on the top of suitable size and as per IP-54 with suitable gasket to make it dust/vermin and all weather proof and should be fabricated from CPRI approved manufacturer with base frame fabricated from 50mmx50mm x6mm thick MS angle iron with 4 legs of 100 cm. long suitable for 415 Volt, 50Hz AC supply with 3 mm thick CRCA sheet on bottom for taking load of cable gland and necessary individual gland plate for cable gland, hinged front open-able door with locking arrangement complete with 300 Amp. 4 strip Al. busbar including grouting the legs of feeder pillar in CC foundation covering three sides up to feeder pillar bottom height duly plastered i/c phosphatized & powder coated painting, connection inter connection, earthing the feeder pillar at two separate points etc. as reqd. (manufacturers having ISO 9001 certification), with following accessories-125 Amp TPMCCB 25KA with spreader link (Ics=100% Icu) - 1 no. as incomer63 Amp TPMCCB 16KA with spreader link (Ics=100% Icu) - 3 nos. as outgoing110 amp 3 Phase Contactor for street light - 1 no.Digitial Timer for street light - 1 no.LED indicating light - 1 set (for RYB)2 Amp SPMCB - 3 Nos.Digital Ameter 3 phase with suitable size CTs -1 set.Digital Voltmeter 3 phase with Selector Switch - 1 set.etc. as required.Qty. for NESD-I - 3 JobsQty. for NESD-III - 3 Jobs |
| 69 | Supplying & lowering of 2.2KW/3 HP submersible pump set capable of delivering 175-35 LPM at a head of 39-73 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing borewell with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required.Qty. for NESD-I |
| 70 | Supplying & lowering of 5 HP Open well submersible pump set capable of delivering 258-60 LPM at a head of 20-34 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing open well with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required.Qty. for NESD-I |
| 71 | Supplying and installation of 3 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 4-6.5 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required. Qty. for NESD-I |
| 72 | Supplying and installation of 5 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 6-10 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required. Qty. for NESD-I |
| 73 | Lifting of existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop.Qty. for NESD-I |
| 74 | Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site.Qty. for NESD-I |
| 75 | Servicing and Overhauling of 3HP /5 HP 3 Phase Motor Pump set i/c varnising , greasing , oiling and making Coupling alignment i/c replacement of bearing etc and re-installation the same, testing and commissioning etc complete as reqd.Qty. for NESD-I |
| 76 | Rewinding of 3HP capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd.Qty. for NESD-I |
| 77 | Rewinding of 5HP capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd.Qty. for NESD-I |
| 78 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required3 Core 6 Sq mm Flat CableQty. for NESD-I |
| 79 | Servicing of 11KV 630 amps. 3 phase 50 Hz Vaccum Circuit Breaker i/c drawing out the VCB, cleaning of components, decarbonising of the arcing chamber, setting right the mechanism, lubricating the moving parts, checking & testing the continuity of control wiring, tightening of connections, of moving & fixed contacts, replacement of minor worn out parts like nut bolts, bushing road replacement & spring washer etc., reinstallation, testing etc. complete as reqd.Qty. for NESD-I |
| 80 | Testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc as required.(a) O/C relay-2 nos.(b) Earth fault relay-1 no.(c) Master relay -1 no.Qty. for NESD-I |
| 81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.a) 40 mm nominal dia PipesQty. for NESD-I |
| 82 | For Operation & Maintenance of Sub-station at Mukarba ChowkDay to day round the clock operation & Routine Maintenance of electrical Sub-Station equipment & associated control switchgear/panels, under deck lighting installed at Mukarba Chowk Sub-Station i/c EI work at Sub-Station under PWD North Electrical Division as per terms & conditions and inventory attached complete as required i/c watch & ward of all electrical & mechanical installation as well as all types of electrical stores lying at mukarba chowk sub station campus area etc. for all days in a week i/c Sundays & Holidays etc as reqd in three shift as per terms & conditionQty. for NESD-I |
| 83 | Dehydration and Filtration of transformer oil of 400 KVA capacity, Overhauling, inspection of transformer by opening inspection plate, dismantling, conservator tank and dismantling radiator wings dismantling, radiator bolt i/c replacement of worn-out gasket of the transformer etc as reqd.Qty. for NESD-I |
| 84 | Top up of transformer oil duly dehydrated in the existing H.T. Bus bar etc. as requiredQty. for NESD-I |
| 85 | Calibration of Over Current and Earth fault relay cleaning of wiring system calibration with secondary injection test kit setting of tripping according to the Load complete with testing and commissioning as reqd.Qty. for NESD-I |
| 86 | Less credit for following dismantle material received from the work.63A/100A/125/160A TP/TPN burntout MCCBs/Power contractorQty. for NESD-I - 15 NosQty. for NESD-III - 60 Nos |
| 87 | Digital Timer/Astro Mini Timer burnt outQty. for NESD-I - 5 NosQty. for NESD-III - 10 Nos |
| 88 | Assorted size Aluminium armoured cableQty. for NESD-I - 900 KgQty. for NESD-III - 2300 Kg |
| 89 | Copper/aluminium wire cut pieces assorted sizeQty. for NESD-I - 100 KgQty. for NESD-III - 25 Kg |
| 90 | 5-32A SP/SPN MCB burnt outQty. for NESD-I - 100 NosQty. for NESD-III - 225 Nos |
| 91 | Existing non functional LED Fittings (90 to 250 watt)Qty. for NESD-I -130 NosQty. for NESD-III - 230 Nos |
| 92 | 8/10/12 Mtr height damaged GI PoleQty. for NESD-I - 5 NosQty. for NESD-III - 10 Nos |
| 93 | 5 Mtr. Height damaged GI PoleQty. for NESD-III |
| 94 | Existing HPSV fittings (250 Watt)Qty. for NESD-III |
| 95 | Damaged Feeder pillar including Accessories like, MCCBs, Timer, Contactors etc.Qty. for NESD-I - 3 JobQty. for NESD-III - 7 Job Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail