| 1 | Supplying installation testing and commissioning of 90 watt LED 6000K asymmetric new generation energy saving and environment long life versatile pressure die cast aluminum IP66 roadway luminaries with high power LED light source complete etc. as required housing reflector and enclosed with toughened glass complete with all accessories, Philips/Bajaj/Crompton/Halonix/Havells. |
| 2 | Repairing and installation of exisiting defective street light with replacement of drivers, retifier, LED plate etc. complete as required at site. |
| 3 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 4 | Supplying of one number PVC insulated and PVC sheathed / XLPE sheathed aluminium Conductor armoured power cable of1.1 kV grade of following size etc complete as reqd. a) 4 x 16 sq. mm |
| 5 | Supplying of one number PVC insulated and PVC sheathed / XLPE sheathed aluminium Conductor armoured power cable of1.1 kV grade of following size etc complete as reqd. b) 4 x 25 sq. mm |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i). 3x2.50 Sqm. |
| 7 | Supplying and erection of flange mounted hot dip Galvanized octagonal Poles of 8 Mtr. Height made from 3mm thick steel plate having bottom Dia of 130 mm & top Dia of 70mm complete with window with flash cover at the height of 2.00 Mtr from the base of cable termination Block etc. and galvanization base plate of size 250mm x 250mm x16mm thick on existing cement concrete pedestal as required including suppling and fixing of laminated sheet, DIN channel, BUS Bar and earth sheet 2 Nos. welded at suitable height as per direction of Enginer-in-charge. 2 Nos. washer, nuts and locking arrangement completed as required (make Bajaj/Volmont/Phillips/Lysaght/Consoul) |
| 8 | Supplying & Fixing of following size Aluminium thimble with proper connection and PVS Tape etc as required. 16 Sqmm |
| 9 | Supplying & Fixing of following size Aluminium thimble with proper connection and PVS Tape etc as required. 25 Sqmm |
| 10 | Fabrication supplying and installation of outdoor type cubical feeder pillar of suitable size not less than 30 cm and upto 45 cm deep made out of M.S. Sheet 2mm thick (14SWG) duly compartmentalized having 4 strip busbar of 200 amp capacity double door with locking arrangements for protection from rain dust duly fixed on M.S. angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) 110 cm long legs out of which 50cm duly grouted in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone agreegate 20mm) having following accessories mounded inside the cubical panel including connection inter connection/soild with aluminum timbles earthing with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality enamel paint completed etc. as required having also compartment for energy meter. Supplying and fixing of following accesssories in the existing cubical panel board/feeder pillar including connection testing etc. as required having also compartment for energy meterSupplying and fixiing of folowing accessories in the existing cubical pnal board/feeder pillar including connection testing etc. as required incomer 125 Amp .35KA MCCB with thermal release 1 No. Outgoing A) 63Amp - DPMCB - 6 Nos. B) 63Amp - ELCB - 1 Nos. C) C.T. Opetrating . D) Tongal Switch E) Voltmeter 0-5000 volts 96 Sqm flush type with selector switch F) Ampere 0-100/5 sqmm Flush type with selector Switch & 100/5 Amp ratio cts G) Indication Lamp (ryb) with control 3 pole (ML-6) 95 Amp H) Power contactor 3pole (ML-6) 95 AMP I) Auto timer Rex modular D41 model MDS make J) Danger notice plate. |
| 11 | Supplying and drawing following sizes of PVC sheathed & XLPE insulated Al. conductor multicore unarmoured cable of 1100 Volts conforming to IS 7098 (Part 1) 1988 with upto Date Amendments in the existing panel ets as required.. a) 3 core 4 sq.mm |
| 12 | Supplying and fixing 4 Nos. 16 mm (minimum) dia X 650 mm(minimum) long GI foundation bolt (EN8grade) with nuts, washer including 2 Nos. template of 3 mm thick size 200 X 200 mm. with 4 Nos. 20 mm. dia holes (or suitable for existing holes), to match with PCD of Pole base plate as required. |
| 13 | Fabricating, supplying and fixing of wire mesh protection frame work fabricating with 40 x 40 x 6 mm thick angle iron/Tee iron having intermediate members of size 25 mm x 6 mm (GI wire should be 6SWG) flat strip welded at 30 cm in each sections & duly welded with hard drawn wire fabric mesh of size 25 mm X 75 mm having weight not less than 7.5 Kg/Sqmtr. and making main door gate provided with two nos. sliding bolt with godown locks with operating hadle welded from inside of the door i/c providing and fixing of four no. legs of same angle size of 90 cm length duly grouted in foundation (30 x 30 x 45) cm (deep) in 1:2:3 cement concrete & painting with one coat of red oxide & two coat of super synthetic luminous paint of approved colour and quality etc.complete as reqd. {Area of hard drawn wire fabric with angle (Except legs) shall be measured for payment} |
| 14 | Fabrication, Designing, Supplying & Fixing of 1000 mm long double arm bracket(Thickness minimum 3MM) over hang with tightening bolt etc. as per design approved by Engineer-In-Charge. |
| 15 | Providing and fixing of locking system of street light including pole door for safety cover plate of M.S sheet including weilding, nut-bolt etc. and painting of door cover plate with synthetic enamel aluminium paint. |
| 16 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- 63 Amp - DPMCB |
| 17 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- 125 AMP TPN |
| 18 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- 63 Amp - MCCB |
| 19 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- CT OPERATING |
| 20 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- TONGAL SWITCH |
| 21 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- POWER CONTACTOR 3 POLE (ML-6) 95 Amp |
| 22 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- Ampere 0-100/5 Sqmm Flush type with selector switch & 100/5 Amp ration cts |
| 23 | Supplying, Installation, Testing and Commissioning of the following Material required for existing feeder panel including all accessories for connetion etc as per site requirement:- timer into the existing street light panel box including all accessories for connection etc. as per site requirement. |
| 24 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 500 mm.(L) X 500 mm. wide and 1200 mm. deep i/c excavation of earth in hard rock, providing cutting, bending and placing in position, steel reinforcement of cold twisted bars of 12 mm. dia- 1300mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2000mm (approx) - 10nos. (with equal spacing) for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete as required with positioning of foundation bolts (as per item below) and providing 63 mm. (O.D) DWC, HDPE Pipe minimum 1 mtr. for cable entry & exit as required. |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth levela) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sqmm |
| 28 | Repairing of defective/faulty cable connection inside the pole window and underground cable by making connection with suitable size PVC insulated copper wire, connector plate, thimble and taping with insulation tape for existing 5 mtr. to 12 mtr. height GI pole i/c testing & commissioning etc. complete as required at site |
| 29 | Laying of al. conductor armoured/unarmourd power cable 1.1 KV between pole to pole with the help of tower wagon, including supplying of 10 SWG GI wire, in following manner,a) Upto 3.5X35 sqmm. Overhead tied with suitable size SchakleClamp and insulator |
| 30 | Painting by double coating aluminium silver paint of street light poles of height 8 Mtr sizes i/c. pole brackets of various designs after cleaning and scrabbing of poles for removing of any posters/rusts if there to give even shade etc. as reqd. |
| 31 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 32 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt,spring,washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 33 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 34 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 35 | Deployment of hydra crane with boom lift cage bracket or other arrangement of required capacity with fuel and driver fro fixing/removal/replacement of lights mounted on pole, bracket, electric wiring pole, pole window accessories etc. as and required as per direction of Engineer in charge. |
| 36 | Deployment of 01 No. skilled/Wiremanm and 01 Nos. Unskilled worker/Helper for day to day maintanence, repairing and watch &ward of the street light on the Bundh roads from Dhansa to Jhatikra for 01 year of I&FC deptt. |
| 37 | Deployment of 01 No. skilled/Wiremanm and 01 Nos. Unskilled worker/Helper for Night shift for maintanence, repairing and watch &ward of the street light on the Bundh roads from Dhansa to Jhatikra for 01 year of I&FC deptt. Please Enable Macros to View BoQ information |