| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead., SCH. NO. 15.56 |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm FLOOR, SCH. NO. 15.23.2 |
| 3 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge., SCH. NO. 1.1.18 |
| 4 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws |
| 5 | (a) Single leaf, SCH. NO. 9.21.1 |
| 6 | (b) Double leaf, SCH. NO. 9.21.1+9.26 |
| 7 | (c)both side laminated., SCH. NO. 9.22.1*2 |
| 8 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides, SCH. NO. 10.29.2 |
| 9 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. (2.25FM), SCH. NO. 13.4.2 |
| 10 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. (2.25FM), SCH. NO. 13.5.2 |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, SCH. NO. 11.41.2 |
| 12 | Providing and laying of KOTA Stone of size 45x 45 cm and above flooring over previously prepared-base with 2cm thick 1:3 cement and sand morter including filling of joints with cement mixed with pigment required for matching the shade of floor as per direction E/I including cutting polishing with wax polish including-supply of all materials T & P etc. required for proper completion of the work., SCH. NO. 11.26.1 |
| 13 | Supply and fixing 5 mm (1/4\\")thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work., SCH. NO. 11.37 |
| 14 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works), SCH. NO. 13.62.1 |
| 15 | Same as above but wooden painting, SCH. NO. 13.62.1 |
| 16 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), SCH. NO. 13.47.1 |
| 17 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats, SCH. NO. 13.51.2 |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , SCH. NO. 13.8 |
| 19 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes, SCH. NO. 10.30.1 |
| 20 | 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. he lock rail made up of 'H' section, a uPVC hollow section of size 00x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge., SCH. NO. 9.118.2 |
| 21 | Providing and laying vitrified floor tiles (Mat Finish) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete., SCH. NO. 11.41.2 |
| 22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete., SCH. NO. 11.37 |
| 23 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm (Qty Taken Item No-3+4), SCH. NO. 11.48.2 |
| 24 | INTERNAL W/S & SANITATION |
| 25 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :, SCH. NO. 17.1 |
| 26 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, SCH. NO. 17.1.1 |
| 27 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, SCH. NO. 17.2 |
| 28 | W.C. pan with ISI marked white solid plastic seat and lid, SCH. NO. 17.2.1 |
| 29 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge, SCH. NO. 17.16A |
| 30 | Supplying, fixing, testing and commissioning of wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps , SCH. NO. DSR -17.7.1,Pg No-266 |
| 31 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings, SCH. NO. 17.8 |
| 32 | One Urinal basin with 5 liter white p.v,c automatic flushing cistern., SCH. NO. 17.4.1 |
| 33 | Granite stone of approved shade, SCH. NO. 8.10.2 |
| 34 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete, SCH. NO. 17.28 |
| 35 | Flexible Pipe, SCH. NO. 17.28.2 |
| 36 | 32mm Dia, SCH. NO. 17.28.2.1 |
| 37 | 40mm Dia, SCH. NO. 17.28.2.2 |
| 38 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. , SCH. NO. 17.69 |
| 39 | Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms, SCH. NO. 17.69.1 |
| 40 | Waste coupling 38 mm dia of 83 mm length and 77 mm breadth weighing not less than 60 gms, SCH. NO. 17.69.2 |
| 41 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete., SCH. NO. 17.31 |
| 42 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. , SCH. NO. 17.33 |
| 43 | Providing and fixing toilet paper holder :, SCH. NO. 17.34 |
| 44 | C.P. brass, SCH. NO. 17.34.1 |
| 45 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms., SCH. NO. 17.71 |
| 46 | Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour., SCH. NO. 17.73 |
| 47 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms, SCH. NO. 17.73.2 |
| 48 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc., SCH. NO. 17.37 |
| 49 | For 100mm dia. Pipe, SCH. NO. 17.37.1 |
| 50 | For 75mm dia. Pipe, SCH. NO. 17.37.2 |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.., SCH. NO. 18.7 |
| 52 | Internal work - Exposed on wall |
| 53 | 15 mm dia nominal bore, SCH. NO. 18.7.1 |
| 54 | 20 mm dia nominal bore, SCH. NO. 18.7.2 |
| 55 | 25 mm dia nominal bore, SCH. NO. 18.7.3 |
| 56 | 32 mm dia nominal bore, SCH. NO. 18.7.4 |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. , SCH. NO. 18.8 |
| 58 | Concealed work, including cutting chases and making good the walls etc. |
| 59 | 15 mm dia nominal bore, SCH. NO. 18.8.1 |
| 60 | 20 mm dia nominal bore, SCH. NO. 18.8.2 |
| 61 | External work |
| 62 | 50 mm dia, nominal bore , SCH. NO. 18.9.6 |
| 63 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank., SCH. NO. 18.48 |
| 64 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends), SCH. NO. 18.17 |
| 65 | 20mm dia, nominal bore, SCH. NO. 18.17.1 |
| 66 | 25 mm dia, nominal bore, SCH. NO. 18.17.2 |
| 67 | 32 mm dia, nominal bore, SCH. NO. 18.17.2 |
| 68 | Providing and fixing uplasticised PVC connection pipe with brass unions :, SCH. NO. 18.21 |
| 69 | 45 cm length , SCH. NO. 18.21.2 |
| 70 | 15 mm nominal bore , SCH. NO. 18.21.2.1 |
| 71 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter , SCH. NO. 18.22.2 |
| 72 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931, SCH. NO. 18.49 |
| 73 | 15mm nominal bore, SCH. NO. 18.49.1 |
| 74 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms., SCH. NO. 18.51 |
| 75 | 15mm nominal bore, SCH. NO. 18.51.1 |
| 76 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931, SCH. NO. 18.53 |
| 77 | 15 mm nominal bore , SCH. NO. 18.53.1 |
| 78 | Providing and fixing PTMT grating of approved quality and colour, SCH. NO. 18.58 |
| 79 | Circular type, SCH. NO. 18.58.1 |
| 80 | 100 mm nominal dia, SCH. NO. 18.58.1.1 |
| 81 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge., SCH. NO. 18.53A |
| 82 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball., SCH. NO. 18.62 |
| 83 | 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms, SCH. NO. 18.62.5 |
| 84 | 15 mm nominal bore, SCH. NO. 18.52.1 |
| 85 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes., SCH. NO. 12.41 |
| 86 | 110 mm diameter, SCH. NO. 12.41.2 |
| 87 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., SCH. NO. 12.42 |
| 88 | Coupler, SCH. NO. 12.42.1 |
| 89 | 110 mm, SCH. NO. 12.42.1.2 |
| 90 | Bend 87.5°, SCH. NO. 12.42.5 |
| 91 | 110 mm bend, SCH. NO. 12.42.5.2 |
| 92 | Shoe (Plain), SCH. NO. 12.42.6 |
| 93 | 110 mm Shoe, SCH. NO. 12.42.6.2 |
| 94 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete., SCH. NO. 12.43 |
| 95 | 110 mm, SCH. NO. 12.43.2 |
| 96 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams., SCH. NO. 12.44 |
| 97 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete., SCH. NO. 12.22 |
| 98 | COST FOR INTERNAL ELECTRIFICATION |
| 99 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT |
| 100 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required., SCH. NO. 1.1 |
| 101 | Group C, SCH. NO. 1.10.3 |
| 102 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required., SCH. NO. 1.11 |
| 103 | SUBMAIN AND CONTROL WIRING |
| 104 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, SCH. NO. 1.14 |
| 105 | 2 X 1.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt Wiring Points), SCH. NO. 1.14.1 |
| 106 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt Wiring Points/TV/ 6 Amp Light Plug), SCH. NO. 1.14.2 |
| 107 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For Sub Main of Each Room), SCH. NO. 1.14.4 |
| 108 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (For UPS Load & Light DB), SCH. NO. 1.14.9 |
| 109 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For Power DB), SCH. NO. 1.14.10 |
| 110 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., SCH. NO. 1.25 |
| 111 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., SCH. NO. 1.26 |
| 112 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required., SCH. NO. 1.32 |
| 113 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required., SCH. NO. 1.55 |
| 114 | Group A, SCH. NO. 1.55.1 |
| 115 | SUB MAIN DISTRIBUTION BOARDS, DISTRIBUTION BOARDS,MCB's, RCCB's, etc. |
| 116 | DISTRIBUTION BOARDS,MCB's, RCCB's |
| 117 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), SCH. NO. 2.3 |
| 118 | 2 + 4 way/6 way, Double door SPN , SCH. NO. 2.3.1 |
| 119 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)- For Distribution of various areas as per SLD, SCH. NO. 2.4 |
| 120 | 8 way (4 + 24), Double door TPN , SCH. NO. 2.4.3 |
| 121 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required., SCH. NO. 2.5 |
| 122 | 8 way (4 + 12), Double door, SCH. NO. 2.5.2 |
| 123 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., SCH. NO. 2.10 |
| 124 | Single pole, SCH. NO. 2.10.1 |
| 125 | Double pole, SCH. NO. 2.10.3 |
| 126 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required., SCH. NO. 2.11 |
| 127 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required., SCH. NO. 2.13 |
| 128 | 40 amps, SCH. NO. 2.13.1 |
| 129 | 63 amps, SCH. NO. 2.13.2 |
| 130 | 100 amps, SCH. NO. 2.13.3 |
| 131 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, , SCH. NO. 8.1 |
| 132 | Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 133 | Powder coated die cast /Extruded aluminum Body including trim |
| 134 | 12-15 W, SCH. NO. 8.1.3 |
| 135 | 18 W, SCH. NO. 8.1.4 |
| 136 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). , SCH. NO. 8.9 |
| 137 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).- Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 138 | 18- 22 watt, SCH. NO. 8.9.1 |
| 139 | Supply, erection, testing and commissioning of 9 W LED Bracket Light wall mounted single phase 220-240V 50 Hz AC ncluding making suitable arrangement for fixing including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required complete as reqd. |
| 140 | LIGHTING CONTROLS |
| 141 | Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. , SCH. NO. 7.2 |
| 142 | BLDC FANS & WALL FANS |
| 143 | Supply, Installation, Testing and Commissioning of following sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos blades, 30 cm long down rod, 2 Nos caNospies, shackle kit, safety rope, copper winding, Power Factor Nost less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required., SCH. NO. 9.1 |
| 144 | 1200mm, service value (Minimum)-≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum), SCH. NO. 9.1.3 |
| 145 | Supply, installation, testing & commissioning of earthing system & associated accessories, etc. complete all as per the instructions of E.I.C. |
| 146 | Note : |
| 147 | 1) Measurements of resistance of each earth station & resistance of complete scheme of earthing layout must be measured recorded & got approved by E.I.C. |
| 148 | 2) Jointing of the earth strip shall be with brass nuts bolts and also with solder joints. |
| 149 | 3) Jointing of the earth wire shall be with solder joints with tinned cable sockets |
| 150 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required., SCH. NO. 5.4 |
| 151 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required., SCH. NO. 5.11 |
| 152 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required., SCH. NO. 5.15 |
| 153 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required., SCH. NO. 5.16 |
| 154 | Providing and fixing MV danger notice plate of 200mm x 150mm made of mild steel, atleast 2 mm thick, and vitreos enamelled white on both sides and with iscription in single red colour on front side as required, SCH. NO. 2.21 |
| 155 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required., SCH. NO. 2.22 |
| 156 | COVERED DRAIN (300X450)MM |
| 157 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches., SCH. NO. 2.8.1 |
| 158 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation , SCH. NO. 4.1.8 |
| 159 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) in 1:1.5:3, SCH. NO. 5.1.2 |
| 160 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. , SCH. NO. 6.1.1 |
| 161 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) F.M. 2.25., SCH. NO. 13.5.1 |
| 162 | P/F TMT Bar -Fe 500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. , SCH. NO. 5.22.6 |
| 163 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 164 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick., SCH. NO. 5.9.20 |
| 165 | CHAIN LINK FENCING |
| 166 | Clearing jungle including uprooting of tank vegetation, grass brass brush wood , trees and saplings of wirth upto 30 cm measured at a height of 1m above ground level and removel of rubbish upto a distance of 50 m outside the preiphery of the area , SCH. NO. 2.31 |
| 167 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches., SCH. NO. 2.6 |
| 168 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation , SCH. NO. 4.1.8 |
| 169 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources), SCH. NO. 4.1.3 |
| 170 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube, SCH. NO. 10.26.1 |
| 171 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in charge., SCH. NO. 16.70.1 |
| 172 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete13.52.2 On steel work, SCH. NO. 13.52.1 Please Enable Macros to View BoQ information |