| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of earth strata complete all as specified and as directed:- |
| 2 | Soft soil |
| 3 | Hard soil |
| 4 | Disintegrated rock |
| 5 | Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of complete and all as specified. |
| 6 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. Complete and all as specified. |
| 7 | Supply and lay Pipe ductile Iron , S/S , Class “K-7” ,150 mm (6”) dia all as specified and directed. |
| 8 | Supply and lay Pipe ductile Iron , S/S , Class “K-7” ,100 mm (6”) dia all as specified and directed. |
| 9 | S & F in replacement, CI sluice valve 200 mm bore size, PN 1.6 conforming to IS 14846/2000, ISI marked with MS spindle and iron wheel head with both ends flanged including jointing material like new rubber gasket/ rubber ring, bolts, and nuts etc and testing after completion including sluice valve with stainless steel spindle and brass check nuts with iron wheel flanged type hole and drilled heavy duty ISI marked class PN-1 including rubber insertion 3mm thick, nut bolts gasket washer etc. complete all as specified and directed. |
| 10 | All as per item No 06 above but for CI sluice valve of size 150 mm bore. |
| 11 | All as per item No 06 above but for CI sluice valve of size 100 mm bore. |
| 12 | All as per item No 06 above but for CI sluice valve of size 80 mm bore. |
| 13 | All as per item No 06 above but for CI sluice valve of size 50 mm bore. |
| 14 | Supply and fix Cast Iron Air Valves with two air Outlets, 150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. |
| 15 | Supply and fix Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. |
| 16 | Supply and fix Cast Iron Non-Return Sluice Valve150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. |
| 17 | Supply and fix Cast Iron Non-Return Sluice Valve100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. |
| 18 | Supply and fix DI/CI Specials/fittings like Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm all as specified and directed |
| 19 | S & F in repair CI Foot valve with one end flanged and neuprone ball with jointing material such as insertion of rubber sheet 3mm thick with MS nut and bolt 12mm dia X 40mm long complete of following sizes |
| 20 | All as item no 16 here in before but 100 mm dia |
| 21 | All as item no 16 here in before but 80 mm dia |
| 22 | Taking out unserviceable sluice valves of size 150 mm dia ,refacing regrinding replacement unserviceable parts and refixing in original position all as directed.(Spare parts for repair sluice valve will be measured and paid seperately in respective items) |
| 23 | All as item no 17 but for size of sluice valve 200 mm dia all as directed. |
| 24 | All as item no 17 but for size of sluice valve 250 mm dia all as directed. |
| 25 | Repair of Defects such as leakage and blockage in CI/DI pipe of size 80 mm to 100 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out. |
| 26 | Repair of Defects such as leakage and blockage in CI/DI pipe of size 150 mm to 200 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out. |
| 27 | S&F Gunmetal spindle suitable for 150 mm dia suitable to match the existing sluice valve |
| 28 | S&F Gunmetal spindle suitable for 200 mm dia suitable to match the existing sluice valve |
| 29 | S&F Gunmetal spindle suitable for 250 mm dia suitable to match the existing sluice valve |
| 30 | S&F Gunmetal spindle suitable for 100 mm dia suitable to match the existing sluice valve |
| 31 | S&F cast Iron stuffing box suitable for 150 mm dia suitable to match the existing sluice valve |
| 32 | S&F cast Iron stuffing box suitable for 200mm dia suitable to match the existing sluice valve |
| 33 | S&F cast Iron stuffing box suitable for 250mm dia suitable to match the existing sluice valve |
| 34 | Supply and lay Pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia all as specified and directed. |
| 35 | Supply and lay Pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia all as specified and directed. |
| 36 | Supply and lay Pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia all as specified and directed. |
| 37 | Supply and lay Pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia all as specified and directed. |
| 38 | Supply and lay Pipe galvanized, “Medium class”, including fittings 20 mm (1”) dia all as specified and directed. |
| 39 | Taking up/down the following unserviceble gate valve of any type any size and Supply and fixing the Gate valve made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed. |
| 40 | All as per items no 32 but size for water pipe 15mm dia all as directed. |
| 41 | All as per items no 32 but size for water pipe 20mm dia all as directed. |
| 42 | All as per items no 32 but size for water pipe 25 mm dia all as directed.. |
| 43 | All as per items no 32 but size for water pipe 40 mm dia all as directed.. |
| 44 | All as per items no 32 but size for water pipe 50 mm dia all as directed.. |
| 45 | All as per items no 32 but size for water pipe 80 mm dia all as directed.. |
| 46 | Cutting chases,pinning in,making good of PCC hard standing to facing where required and pointing in cement mortar 1:3 , exc.10 cm. but not exc.20 cm girth to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size all as specified and directed. |
| 47 | Cutting Bituminous road in making good with facing where required and pointing exc. 30 cm. but not exc.1.0 mtr. girth to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size all as specified and directed. |
| 48 | Repair of Defects such as leakage and blockage in GI pipe of size 15 mm to 80 mm including T&P and neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting,threading and jointing as per site requirement using new GI fittings as required following sizes:- Note :- (a) fittings reqd will be paid Separately. (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out (c) Contractor shall be responsible to repair defects at any place |
| 49 | 15 mm dia. |
| 50 | 20 mm dia. |
| 51 | 25 mm dia |
| 52 | 40 mm dia. |
| 53 | 50 mm dia. |
| 54 | 80 mm dia. |
| 55 | Supply only Elbow of following sizes :- |
| 56 | Elbow 15mm |
| 57 | Elbow 20mm |
| 58 | Elbow 25mm |
| 59 | Elbow 40mm |
| 60 | Elbow 50mm |
| 61 | Elbow 80mm |
| 62 | Supply only TEE of following sizes :- |
| 63 | Tee 15mm |
| 64 | Tee 20mm |
| 65 | Tee 25mm |
| 66 | Tee 40mm |
| 67 | Tee 50mm |
| 68 | Tee 80mm |
| 69 | Supply only Union of following sizes :- |
| 70 | Union 15mm |
| 71 | Union 20mm |
| 72 | Union 25mm |
| 73 | Union 40mm |
| 74 | Union 50mm |
| 75 | Union 80mm |
| 76 | Supply only Coupling (GI Socket) of following sizes :- |
| 77 | Coupling 15mm |
| 78 | Coupling 20mm |
| 79 | Coupling 25mm |
| 80 | Coupling 40mm |
| 81 | Coupling 50mm |
| 82 | Coupling 80mm |
| 83 | Supply only NIPPLE of any length and following sizes :- |
| 84 | Nipple 15mm |
| 85 | Nipple 20mm |
| 86 | Nipple 25mm |
| 87 | Nipple 40mm |
| 88 | Nipple 50mm |
| 89 | Nipple 80mm |
| 90 | Supply only Stop Plug of following sizes :- |
| 91 | Stop plug 15mm |
| 92 | Stop plug 20mm |
| 93 | Stop plug 25mm |
| 94 | Stop plug 40mm |
| 95 | Stop plug 50mm |
| 96 | Stop plug 80mm |
| 97 | Supply only Barrel Piece of following sizes |
| 98 | Barrel nipple 80mm' long 15mm dia |
| 99 | Barrel nipple 80mm' long 20 mm dia |
| 100 | Barrel nipple 80mm' long 25mm dia |
| 101 | Barrel nipple 80mm' long 40 mm dia |
| 102 | Barrel nipple 80mm' long 50mm dia |
| 103 | Barrel nipple 80mm' long 80 mm dia |
| 104 | Supply only GI Reducer Coupling of following sizes |
| 105 | GI Reducer Coupling 20/15mm |
| 106 | GI Reducer Coupling 25/20mm |
| 107 | GI Reducer Coupling 25/15mm |
| 108 | GI Reducer Coupling 50/25mm |
| 109 | GI Reducer Coupling 3''/2” |
| 110 | Supply only GI Reducer Elbow of following sizes |
| 111 | GI Reducer Elbow 20/15mm |
| 112 | GI Reducer Elbow 25/20mm |
| 113 | GI Reducer Elbow 25/15mm |
| 114 | GI Reducer Elbow 50/25mm |
| 115 | Supply & fix of rubber packing sheet 6 mm Thick all as specified and directed. |
| 116 | Supply & fix MS nut and bolt including washer suitable for fixing sluice valve all as specified and directed. |
| 117 | Taking up or down the following size steel galvanized water tubing with all necessary fittings complete from walls / floor or trenches all as directed. |
| 118 | All as per items no 47 but size for water pipe 40/50mm dia. |
| 119 | All as per items no 47 but size for water pipe 25mm dia. |
| 120 | All as per items no 47 but size for water pipe 80 mm dia. |
| 121 | All as per items no 47 but size for water pipe 100 mm dia. |
| 122 | Cleaning, washing, descalling the following sizes serviceable GI pipe .Refixing/re-laying in same icluding necessary fitting/ fixture in same tranches or new location all as directed |
| 123 | All as per items No 48 but for size for water pipe 40/50 mm dia. |
| 124 | All as per items No 48 but for size for water pipe 25mm dia. |
| 125 | All as per items No 48 size for for water pipe 80 mm dia. |
| 126 | All as per items No 48 size for water pipe 100 mm dia. |
| 127 | S&F in replacement, Ball float valves of 25 mm dia, high pressure, with polythene float and flynut complete, screwed for UPVC pipe or iron pipe or brass ferrule and fixed and tested complete inclding ncecessary UPVC/GI tubing required at site complete all as specified and directed. |
| 128 | Ditto all as per item No 49 but for Ball float valve of 20 mm dia. |
| 129 | Supply and lay Unplasticized (U-PVC) Pipes of pressure rating 10 kgf/sq. cm including all fitting and Fixtures of Size 40 mm bore inner dia all as specified and directed. |
| 130 | Supply and lay Unplasticized (U-PVC) Pipes of pressure rating 10 kgf/sq. cm including all fitting and Fixtures of Size 32 mm bore inner dia all as specified and directed. |
| 131 | Supply and lay Unplasticized (U-PVC) Pipes of pressure rating 10 kgf/sq. cm including all fitting and Fixtures of Size 25 mm bore inner dia all as specified and directed. |
| 132 | Supply and lay Unplasticized (U-PVC) Pipes of pressure rating 10 kgf/sq. cm including all fitting and Fixtures of Size 20 mm bore inner dia all as specified and directed. |
| 133 | Taking up/down the following unserviceble UPVC Ball valve of any type any size and Supply and fixing the ball valve made with. with iron wheel head, screwed both ends on UPVC pipes all as per directed.. |
| 134 | All as per items no 55 but size for UPVC ball valve 20mm dia all as directed. |
| 135 | All as per items no 55 but size for UPVC ball valve 25 mm dia all as directed.. |
| 136 | All as per items no 55 but size for UPVC ball valve 40 mm dia all as directed.. |
| 137 | M & L for valve chamber of size, type and construction of brick masonry valve chamber of size 1.20m x 1.20m x 1.20m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 10mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified. |
| 138 | M & L for valve chamber of any size, type and construction of brick masonry valve chamber of size 0.90m x0.9m x 0.9m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 10mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified. |
| 139 | M & L for valve chamber of size, type and construction of brick masonry valve chamber of size 0.6m x 0.6m x 0.6m (internal dimension) with 15cm thick foundation using PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) over 15cm thick hardcore, 23cm thick brick wall built in cement and sand mortar (1:4), 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3 finished even and smooth, without using extra cement, 10mm thick MS sheet cover with, 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangements & handle made out of 25cm dia MS round bar, hold fasts etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface including excavation and earth wotk in any type of soil and disposal of surplus soil to a distance n.exc 50m complete all as specified. |
| 140 | Supply only Alum Ferric Compound of approved quality as specified and directed. Please Enable Macros to View BoQ information |