| 1 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches not exc 1.5 m wide and exc 1.5 m but not exc 3 m in depth for foundation etc etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed. |
| 3 | M&L for PCC 1:4:8 Type D2 (40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 4 | M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 (20 mm graded aggregare) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass complete all as specified and directed. |
| 5 | M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 (20 mm graded aggregare) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 6 | M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 (20 mm graded aggregare) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 8 | Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 9 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter of flat rough finished surfaces of concrete complete all as specified and directed. |
| 10 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and directed. |
| 11 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished flat surface of concrete complete all as specified and directed. |
| 12 | M&L for Mild steel TMT bars 10 mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L for Mild steel TMT bars 6mm to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 14 | Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed |
| 15 | M&L Pre cast cement concrete solid block masonry 1:3:6 type C-1 (using 20mm aggregate) with solid block exc 10cm in width setting in CM 1:6 etc complete all as specified and directed. |
| 16 | Providing, cement concrete type B-1 (1:2:4) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 17 | M&L for 20 mm thick Granite (of any type) work (table rubbled and polished) in steps, Jambs, Pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 10 mm thick rendering complete all as specified and directed. |
| 18 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed |
| 19 | M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub based floor complete all as specified and directed. |
| 20 | M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of cement mortar in 1:6 for laying floor finishes complete all as specified and directed. |
| 21 | M&L for Coloured Glazed ceramic tiles in vertical surface of size 450X 300X 7 mm thick over and including 10 mm thick back coat of cement mortar in 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and directed. |
| 22 | Demolition of plain unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 23 | M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) in subbase of floor etc complete all as specified and directed. |
| 24 | Supply and fixing LED flood light 100 watt warm white 230V AC outdoor type with thermal management in protection IP65 and lumen of 14000 and life span of > 60000hr, with impact and corrosion resistant complete with driver and lamp and all the equipment needed for installation compete all as specified and directed |
| 25 | M&L for Framed brackets of angles or tees as a housing for flood lights on poles with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc n.exc 10 Kg each brackets, conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 26 | M&L for lay cable PVC insulated industrial flexible FR 1100 volt grade with stranded copper conductor of size 1.5 Sqmm 2 Core from junction box to lights input terminal complete all as specified and directed. |
| 27 | S&F of LED glare free bollard light 20 W lumen output of 1300 lm and P-65 rating with a life span of 50000 hrs of completed with die cast aluminium spigot, spun aluminium powdr coated top cover, aluminium PDC heat sink, opal PC diffuser and clear acrylic, including all other required accessories complete all as specified and directed. |
| 28 | Supply and laying or fixing or passing through pipe XLPE insulated, Armoured, UG cable (Heavy Dutty) with Aluminium Conductor, 1100 Volt Grade as per IS 7088 (Part-I) 1988 having nominal Cross-sectional area 6 Sqmm 2 Core including Brass Lug etc including taking down complete all as specified and directed. |
| 29 | M&L plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed for the poles and stay |
| 30 | M&L dry fine sand cushioning in Trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and directed. (Punned thickness shall be measured and paid) |
| 31 | S&F sub clas 'B' brick well burnt local made of best quality, laid breadth wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed |
| 32 | S&F of tubes, light grade galvanised 50mm bore with all fitting and fixed complete to walss and ceilings or laid in floors to run cables through them for its protection including all the accessories required complete all as specified and directed. Please Enable Macros to View BoQ information |